FDA Adverse Event Injury Summary report: N

HANAULUX 3004

MDR report key: 8488320 · Received April 5, 2019

Report

Report Number
9710055-2019-00119
Event Type
Injury
Date Received
April 5, 2019
Date of Event
April 4, 2019
Report Date
June 26, 2019
Manufacturer
MAQUET SAS
Product Code
FSY
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
TU
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

THE ISSUE IS STILL BEING INVESTIGATED BY MANUFACTURING SITE. GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET SAS, PARC DE LIMÈRE, AVENUE DE LA POMME DE PI ORLÉANS CEDEX 2, FRANCE 45074. EXEMPTION # E2018005. GETINGE USA SALES, LLC, 45 BARBOUR POND DRIVE, WAYNE, NJ 07470. CONTACT PERSON: (B)(4).

Additional Manufacturer Narrative · 0

GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET SAS, PARC DE LIMÈRE, AVENUE DE LA POMME DE PI ORLÉANS CEDEX 2, FRANCE 45074. EXEMPTION # E2018005. GETINGE USA SALES, LLC, 45 BARBOUR POND DRIVE WAYNE, NJ 07470. CONTACT PERSON: (B)(4). ON 4TH APRIL, 2019 MAQUET SAS BECAME AWARE OF AN EVENT WITH ONE OF THE SURGICAL LIGHT- HANAULUX 3004. AS IT WAS STATED, AT THE BEGINNING OF THE SURGERY LIGHT HEAD OF THE DEVICE FELL DOWN ON PATIENT'S HEAD. THE SURGERY WAS DELAYED AND PATIENT WAS TAKEN TO TOMOGRAPHY AS HE HAD THE SWELLING ON THE HEAD. FORTUNATELY, NO OTHER INJURIES WERE FOUND. IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE SURGICAL LIGHT DID NOT MEET THE MANUFACTURER¿S SPECIFICATION. DURING THE EVENT OCCURRENCE, THE DEVICE WAS BEING USED FOR PATIENT TREATMENT. DURING THIS INVESTIGATION IT WAS ESTABLISHED THAT THE REPORTED ISSUE HAS RESULTED IN A SERIOUS INJURY OR WORSE. THE BREAKAGE APPEARED DUE TO THE TEARING OF THE SPRING ARM TUBE ON THE EDGE OF THE WELDING JOINT. THE SPRING ARM USED IN THE DEVICE IS OF PRODUCTION YEAR 2005. THE SPRING ARM DESIGN WAS ADAPTED BY INCREASING THE THICKNESS OF THE TUBE FROM 2006 PRODUCTION ONWARDS. THE OLD VERSION OF THE TUBE HAS 1,35 MM OF THICKNESS, WHEREAS THE NEW VERSION OF TUBE HAS 2,35 MM. AS A RESULT, THE EXTERNAL DIAMETER OF TUBE HAS INCREASED TO 34 MM. WE HAVE ADDRESSED THIS ISSUE WITH A PREVIOUS FIELD ACTION MSA-2009-003-IU[Z-0182/188-2010] AND SINCE WE SEE RECURRENCE OF THE EVENTS - AS WE RECEIVED NEW COMPLAINTS FROM CERTAIN MARKETS WHERE THESE DEVICES ARE STILL IN USE- WE STARTED FIELD ACTION MSA-2017-002-IU IN THOSE MARKETS. MOREOVER, IT IS WORTH TO BE NOTED THAT THE SALES AND SERVICE UNIT OPENED A CAPA DUE TO THE ISSUE OCCURRENCE. IT APPEARED, THAT EVEN IF THE PRODUCT WAS AFFECTED BY MSA/2017/002/IU FIELD SAFETY CORRECTIVE ACTION, HOWEVER THE SERVICE TECHNICIAN CHECKED THE WRONG PRODUCT (VOLISTA, NOT HANAULUX) IN THE HOSPITAL IN FEBRUARY, 2019. THE ROOT CAUSE OF THIS HAS BEEN IDENTIFIED AS A LACK OF TRAINING AND COMMUNICATION. TO SUM THE ISSUE UP, THE ROOT CAUSE OF THIS ISSUE IS MIXED ¿ A DESIGN ISSUE EXISTED, BUT WAS FAILED TO BE CORRECTLY ADDRESSED DUE TO A SALES AND SERVICE UNIT ERROR IN PERFORMING A FIELD ACTION, WHICH IN TURN LED TO THE EVENT OCCURRENCE.

Additional Manufacturer Narrative · 0

GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET SAS, PARC DE LIMÈRE, AVENUE DE LA POMME DE PI ORLÉANS CEDEX 2, FRANCE 45074. EXEMPTION # E2018005. (B)(6). ON 4TH APRIL, 2019 MAQUET SAS BECAME AWARE OF AN EVENT WITH ONE OF THE SURGICAL LIGHT- HANAULUX 3004. AS IT WAS STATED, AT THE BEGINNING OF THE SURGERY LIGHT HEAD OF THE DEVICE FELL DOWN ON PATIENT'S HEAD. THE SURGERY WAS DELAYED AND PATIENT WAS TAKEN TO TOMOGRAPHY AS HE HAD THE SWELLING ON THE HEAD. FORTUNATELY, NO OTHER INJURIES WERE FOUND. IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE SURGICAL LIGHT DID NOT MEET THE MANUFACTURER¿S SPECIFICATION. DURING THE EVENT OCCURRENCE, THE DEVICE WAS BEING USED FOR PATIENT TREATMENT. DURING THIS INVESTIGATION IT WAS ESTABLISHED THAT THE REPORTED ISSUE HAS RESULTED IN A SERIOUS INJURY OR WORSE. THE BREAKAGE APPEARED DUE TO THE TEARING OF THE SPRING ARM TUBE ON THE EDGE OF THE WELDING JOINT. THE SPRING ARM USED IN THE DEVICE IS OF PRODUCTION YEAR 2005. THE SPRING ARM DESIGN WAS ADAPTED BY INCREASING THE THICKNESS OF THE TUBE FROM 2006 PRODUCTION ONWARDS. THE OLD VERSION OF THE TUBE HAS 1,35 MM OF THICKNESS, WHEREAS THE NEW VERSION OF TUBE HAS 2,35 MM. AS A RESULT, THE EXTERNAL DIAMETER OF TUBE HAS INCREASED TO 34 MM. WE HAVE ADDRESSED THIS ISSUE WITH A PREVIOUS FIELD ACTION MSA-2009-003-IU[Z-0182/188-2010] AND SINCE WE SEE RECURRENCE OF THE EVENTS AS WE RECEIVED NEW COMPLAINTS FROM CERTAIN MARKETS WHERE THESE DEVICES ARE STILL IN USE- WE STARTED FIELD ACTION MSA-2017-002-IU IN THOSE MARKETS. MOREOVER, IT IS WORTH TO BE NOTED THAT THE SALES AND SERVICE UNIT OPENED A CAPA DUE TO THE ISSUE OCCURRENCE. IT APPEARED, THAT EVEN IF THE PRODUCT WAS AFFECTED BY MSA/2017/002/IU FIELD SAFETY CORRECTIVE ACTION, HOWEVER THE SERVICE TECHNICIAN CHECKED THE WRONG PRODUCT (VOLISTA, NOT HANAULUX) IN THE HOSPITAL IN FEBRUARY, 2019. THE ROOT CAUSE OF THIS HAS BEEN IDENTIFIED AS A LACK OF PRODUCT TRACEABILITY, COMMUNICATION AND INFORMING THE EMPLOYEE. TO SUM THE ISSUE UP, THE ROOT CAUSE OF THIS ISSUE IS MIXED A DESIGN ISSUE EXISTED, BUT WAS FAILED TO BE CORRECTLY ADDRESSED DUE TO A SALES AND SERVICE UNIT ERROR IN PERFORMING A FIELD ACTION, WHICH IN TURN LED TO THE EVENT OCCURRENCE.

Description of Event or Problem · 0

ON (B)(6) 2019 MAQUET (B)(4) BECAME AWARE OF AN EVENT WITH ONE OF THE SURGICAL LIGHT- HANAULUX 3004. AS IT WAS STATED, AT THE BEGINNING OF THE SURGERY LIGHT HEAD OF THE DEVICE FELL DOWN ON PATIENT'S HEAD. THE SURGERY WAS DELAYED AND PATIENT WAS TAKEN TO TOMOGRAPHY AS HE HAD THE SWELLING ON THE HEAD. MANUFACTURER REFERENCE NUMBER: (B)(4).

Description of Event or Problem · 0

MANUFACTURER REFERENCE NUMBER: (B)(4).

Description of Event or Problem · 0

MANUFACTURER REFERENCE NUMBER: (B)(4).

Additional Manufacturer Narrative · 1

THE ISSUE IS STILL BEING INVESTIGATED BY MANUFACTURING SITE. (B)(4). EXEMPTION # E2018005. (B)(4).

Additional Manufacturer Narrative · 1

THE ISSUE IS STILL BEING INVESTIGATED BY MANUFACTURING SITE. (B)(4). EXEMPTION # E2018005. (B)(4).

Description of Event or Problem · 1

MANUFACTURER REFERENCE NUMBER: (B)(4).

Description of Event or Problem · 1

MANUFACTURER REFERENCE NUMBER: (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
280518 HANAULUX 3004 LIGHT, SURGICAL, CEILING MOUNTED FSY MAQUET SAS

Patients

Seq Age Sex Outcome Treatment
1 Other