SYRINGE 0.5ML 29GA 12.7MM BLISTER 200BX
Report
- Report Number
- 1920898-2019-00322
- Event Type
- Malfunction
- Date Received
- April 5, 2019
- Date of Event
- March 20, 2019
- Report Date
- June 4, 2019
- Manufacturer
- BD MEDICAL - DIABETES CARE
- Product Code
- FMF
- PMA / PMN Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
INVESTIGATION: CUSTOMER RETURNED PHOTOS OF A 1/2CC, 12.7MM, 29G SYRINGE WITH THE BLISTER PACK FROM LOT # 7240991. CUSTOMER STATES THAT THE BARREL IS DESTROYED. THE ATTACHED PHOTOS WERE EXAMINED AND EXHIBITED CRACKS IN THE BARREL RANGING FROM THE 0-15 UNIT MARKINGS. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH# 7240991. ALL INSPECTIONS AND CHALLENGES WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. THERE WERE THREE (3) NOTIFICATIONS [200720172, 200720171, 200706852] NOTED FOR DAMAGED BARREL. THERE WERE TWO (2) NOTIFICATIONS [200705296, 200704761] NOTED FOR DAMAGED TIPS. THERE WERE TEN (10) NOTIFICATIONS [200719948, 200720205, 200720038, 200720172, 200719960, 200719959, 200720006, 200704761, 200706359, 200706592] NOTED THAT DID NOT PERTAIN TO THE COMPLAINT. POSSIBLE ROOT CAUSES: DEFECT COULD HAVE OCCURRED AT THE PREP DIAL OF THE METRO ASSEMBLY MACHINE LOSS OF BACK PRESSURE ON THE IN-FEED RAIL MAY CAUSE THE BARREL TO BECOME PINCHED AT THE RAIL / PREP DIAL JUNCTION. THE TRIP GATE EYE SENSOR SHOULD DETECT LOW RAIL CONDITIONS AND ACTIVATE THE TRIP GATE TO PREVENT THE BARRELS FROM BEING LOADED INTO THE PREP DIAL AND POSSIBLY JAMMING AT THAT LOCATION; INFEED DIAL AT BARREL PRINTERS; LOSS OF BACK PRESSURE AT INFEED RAIL ALSO AT FORM FILL & SEAL.
IT WAS REPORTED THE SYRINGE 0.5ML 29GA 12.7MM BLISTER 200BX BARREL WAS FOUND DAMAGED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM GERMAN TO ENGLISH: "THE SYRINGE BARREL ARE DESTROYED".
A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.
IT WAS REPORTED THE SYRINGE 0.5ML 29GA 12.7MM BLISTER 200BX BARREL WAS FOUND DAMAGED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM (B)(6) TO ENGLISH: "THE SYRINGE BARREL ARE DESTROYED."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 282082 | SYRINGE 0.5ML 29GA 12.7MM BLISTER 200BX | PISTON SYRINGE | FMF | BD MEDICAL - DIABETES CARE | 7240991 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |