FDA Adverse Event Injury Summary report: N

PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT

MDR report key: 8471353 · Received April 1, 2019

Report

Report Number
2210968-2019-79870
Event Type
Injury
Date Received
April 1, 2019
Report Date
March 4, 2019
Manufacturer
ETHICON INC.
Product Code
GAW
PMA / PMN Number
K133356
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS THROUGH A JOURNAL ARTICLE. NO SPECIFIC PATIENT INFORMATION REGARDING EVENTS HAS BEEN PROVIDED AND IT IS UNKNOWN IF THE EVENTS HAVE BEEN PREVIOUSLY REPORTED. THE MANUFACTURING RECORD EVALUATION CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. REFERENCE JOURNAL ARTICLE: AUTHOR: SUDHIR KUMAR JAIN MS FRCS, M JAYANT MBBS MS, C NORBU MBBS CITATION: TROPICAL DOCTOR. 2008; 38: 80¿82. DOI: 10.1258/TD.2007.060031.

Description of Event or Problem · 1

IT WAS REPORTED IN A JOURNAL ARTICLE ENTITLED: THE ROLE OF ANTIBIOTIC PROPHYLAXIS IN MESH REPAIR OF PRIMARY INGUINAL HERNIAS USING PROLENE HERNIA SYSTEM: A RANDOMIZED PROSPECTIVE DOUBLE-BLIND CONTROL TRIAL. ANTIBIOTIC PROPHYLAXIS IS BEING COMMONLY USED IN MESH REPAIR OF INGUINAL HERNIA BUT ITS ROLE HAS BEEN QUESTIONED IN A RECENT COCHRANE ANALYSIS PERFORMED IN 2003. IN A PRESENT DOUBLE-BLIND PLACEBO CONTROLLED TRIAL INVOLVING 120 PATIENTS (60 PATIENTS ¿ ANTIBIOTIC GROUP; MEAN AGE: 41.28 ± 11.49; ALL MALE PATIENTS; 60 PATIENTS ¿ PLACEBO GROUP; MEAN AGE: 40.2 ± 9.84; ALL MALE PATIENTS) UNDERGOING INGUINAL HERNIA REPAIR USING PROLENE HERNIA SYSTEM (ETHICON), THE AUTHORS DID NOT FIND ANY BENEFIT OF THE ROUTINE USE OF ANTIBIOTIC PROPHYLAXIS IN TERMS OF WOUND INFECTION RATE. ALL PHS MESH REPAIR (COMBINATION OF ONLAY AND OUTLAY MESH) WERE PERFORMED BY THE AUTHORS. ONLAY MESH WAS FIXED WITH PROLENE 2-0 SUTURES (ETHICON). IN THE ANTIBIOTIC GROUP, REPORTED COMPLICATIONS INCLUDED URINARY RETENTION (N-1), SEROMA FORMATION (N-1) WHICH WAS TREATED CONSERVATIVELY BY ASPIRATION WITHOUT ANY SEQUEL, SUPERFICIAL WOUND INFECTION (N-1) WHICH REQUIRED APPROPRIATE ANTIBIOTICS AND DRAINAGE, AND POST-OPERATIVE HYDROCELE (N-1) WHICH WAS TREATED BY EVERSION OF THE SAC. IN THE PLACEBO GROUP, REPORTED COMPLICATIONS INCLUDED SEROMA FORMATION (N-1) WHICH WAS TREATED CONSERVATIVELY BY ASPIRATION WITHOUT ANY SEQUEL AND SUPERFICIAL WOUND INFECTION (N-1) WHICH REQUIRED APPROPRIATE ANTIBIOTICS AND DRAINAGE. IT WAS REPORTED THAT THE PRESENT SERIES SEEMS TO BE THE FIRST TO STUDY THE ROLE OF ANTIBIOTIC PROPHYLAXIS IN REPAIRS OF INGUINAL HERNIA USING PHS. THE AUTHORS BELIEVED THAT THIS PRACTICE CAN BE APPLIED TO ANY TYPE OF MESH REPAIR IN INGUINAL HERNIA BUT THE AUTHORS DO NOT RECOMMEND IT FOR MESH REPAIR OF VENTRAL HERNIA AS THAT INVOLVES EXTENSIVE DISSECTION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
263387 PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT SUTURE, NONABSORBABLE GAW ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention