FDA Adverse Event Malfunction Summary report: N

HANAULUX 3000

MDR report key: 8460203 · Received March 28, 2019

Report

Report Number
9710055-2019-00103
Event Type
Malfunction
Date Received
March 28, 2019
Report Date
June 13, 2019
Manufacturer
MAQUET SAS
Product Code
FSY
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
SA
Reporter Occupation
BIOMEDICAL ENGINEER

Narratives

Additional Manufacturer Narrative · 0

ON (B)(6) 2019 MAQUET SAS BECAME AWARE OF AN INCIDENT WITH ONE OF THE SURGICAL LIGHTS- HANAULUX 3000. AS IT WAS STATED BY THE CUSTOMER, THE LIGHT HEAD OF THE DEVICE FELL DOWN IN THE OPERATING ROOM DURING THE PROCESSING OF THE ROOM BY THE OPERATION TEAM. THE ISSUE RESULTED IN A SHOULDER INJURY OF THE NURSE, HOWEVER SO FAR WE DID NOT RECEIVE ANY INFORMATION IF IT REQUIRED MEDICAL INTERVENTION. IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE SURGICAL LIGHT DID NOT MEET THE MANUFACTURER¿S SPECIFICATION. DURING THE EVENT OCCURRENCE, THE DEVICE WAS BEING USED FOR PATIENT TREATMENT. DURING THIS INVESTIGATION IT WAS ESTABLISHED THAT THE REPORTED ISSUE HAS RESULTED IN A SERIOUS INJURY OR WORSE. THE BREAKAGE APPEARED DUE TO THE TEARING OF THE SPRING ARM TUBE ON THE EDGE OF THE WELDING JOINT. THE SPRING ARM USED IN THE DEVICE IS OF PRODUCTION YEAR 2005. THE SPRING ARM DESIGN WAS ADAPTED BY INCREASING THE THICKNESS OF THE TUBE FROM 2006 PRODUCTION ONWARDS. THE OLD VERSION OF THE TUBE HAS 1,35 MM OF THICKNESS, WHEREAS THE NEW VERSION OF TUBE HAS 2,35 MM. AS A RESULT, THE EXTERNAL DIAMETER OF TUBE HAS INCREASED TO 34 MM. WE HAVE ADDRESSED THIS ISSUE WITH A PREVIOUS FIELD ACTION MSA-2009-003-IU[Z-0182/188-2010] AND SINCE WE SEE RECURRENCE OF THE EVENTS - AS WE RECEIVED NEW COMPLAINTS FROM CERTAIN MARKETS WHERE THESE DEVICES ARE STILL IN USE- WE STARTED FIELD ACTION MSA-2017-002-IU IN THOSE MARKETS. THE DEVICE INVOLVED IN THIS EVENT IS AFFECTED BY THIS FIELD ACTION. GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET SAS, (B)(4). EXEMPTION # E2018005. (B)(4).

Additional Manufacturer Narrative · 0

THE ISSUE IS BEING INVESTIGATED BY MANUFACTURING SITE. GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET SAS, PARC DE LIMÈRE, AVENUE DE LA POMME DE PI ORLÉANS CEDEX 2, FRANCE 45074 EXEMPTION # E2018005. GETINGE USA SALES, LLC, 45 BARBOUR POND DRIVE, WAYNE, NJ 07470. CONTACT PERSON: (B)(4).

Description of Event or Problem · 0

MANUFACTURER REFERENCE NUMBER (B)(4).

Description of Event or Problem · 0

ON 14TH MARCH, 2019 MAQUET SAS BECAME AWARE OF AN INCIDENT WITH ONE OF THE SURGICAL LIGHTS- HANAULUX 3000. AS IT WAS STATED BY THE CUSTOMER, THE LIGHT HEAD OF THE DEVICE FELL DOWN IN THE OPERATING ROOM DURING THE PROCESSING OF THE ROOM BY THE OPERATION TEAM. THE ISSUE RESULTED IN A SHOULDER INJURY OF THE NURSE, HOWEVER SO FAR WE DID NOT RECEIVE ANY INFORMATION IF IT REQUIRED MEDICAL INTERVENTION. MOREOVER, THE CEILING OF THE OPERATING ROOM WAS ALSO DAMAGED AS THE REMAINING PART OF THE SPRING ARM HIT IT. MANUFACTURER REFERENCE NUMBER (B)(4).

Additional Manufacturer Narrative · 1

THE ISSUE IS STILL BEING INVESTIGATED BY MANUFACTURING SITE. (B)(4). EXEMPTION # E2018005. (B)(4).

Additional Manufacturer Narrative · 1

THE ISSUE IS STILL BEING INVESTIGATED BY MANUFACTURING SITE. (B)(4). EXEMPTION # E2018005. (B)(4).

Additional Manufacturer Narrative · 1

THE ISSUE IS STILL INVESTIGATED BY MANUFACTURING SITE. (B)(4). EXEMPTION # E2018005. (B)(4).

Additional Manufacturer Narrative · 1

IT APPEARED THAT THE DEVICE INVOLVED IN THIS ISSUE IS INCLUDED IN THE SCOPE OF FIELD SAFETY CORRECTIVE ACTION (B)(4). EXEMPTION # E2018005. (B)(4).

Description of Event or Problem · 1

MANUFACTURER REFERENCE NUMBER (B)(4).

Description of Event or Problem · 1

MANUFACTURER REFERENCE NUMBER (B)(4).

Description of Event or Problem · 1

MANUFACTURER REFERENCE NUMBER (B)(4).

Description of Event or Problem · 1

MANUFACTURER REFERENCE NUMBER (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
255506 HANAULUX 3000 LIGHT, SURGICAL, CEILING MOUNTED FSY MAQUET SAS

Patients

Seq Age Sex Outcome Treatment
1 Other