INTRASTENT MAX LD
Report
- Report Number
- 2183870-2019-00134
- Event Type
- Malfunction
- Date Received
- March 15, 2019
- Date of Event
- December 25, 2018
- Report Date
- March 15, 2019
- Manufacturer
- COVIDIEN
- Product Code
- FGE
- PMA / PMN Number
- K020528
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- PHYSICIAN
Narratives
AGE OR DATE OF BIRTH: AVERAGE AGE. SEX: MAJORITY GENDER. DATE OF EVENT: DATE OF PUBLICATION. JOURNAL ARTICLE TITLE: "PREDICTIVE FACTORS FOR RESIDUAL HYPERTENSION FOLLOWING AORTIC COARCTATION STENTING." J CLIN HYPERTENS. 2019; 21: 291¿298. WILEYONLINELIBRARY.COM/JOURNAL/JCH ©2018 WILEY PERIODICALS, INC., 291 XAVIER IRIART. HTTPS://ORCID.ORG/0000-0002-4911-7432. RECEIVED: 8 JULY 2018, REVISED: 23 SEPTEMBER 2018, ACCEPTED: 5 OCTOBER 2018. DOI: 10.1111/JCH.13452. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
THE AIM OF THIS RETROSPECTIVE STUDY WAS TO IDENTIFY THE PREDICTIVE FACTORS FOR RESIDUAL HT IN PATIENTS WHO HAD UNDERGONE COA STENTING. THIRTY CONSECUTIVE PATIENTS WHO HAD UNDERGONE COA STENTING BETWEEN 2007 AND 2015 WERE INCLUDED IN THE STUDY. ALL PROCEDURES WERE PERFORMED BY A SINGLE EXPERIENCED OPERATOR. THE TECHNICAL PARAMETERS WERE RECORDED DURING THE PROCEDURE. THE OPTIMAL OUTCOME OF THE PROCEDURE WAS DEFINED AS A RESIDUAL GRADIENT OF 10MM HG. THE LENGTH OF THE STENT WAS CHOSEN IN ORDER TO NORMALIZE THE PRESSURE GRADIENT BETWEEN THE ASCENDING AND DESCENDING AORTA CAUSED BY VARIOUS ANOMALIES RANGING FROM FOCAL NARROWING OF THE ISTHMIC AREA (DISTAL TO THE LEFT SUBCLAVIAN ARTERY), TO DIFFUSE AORTIC ARCH HYPOPLASIA. AS CHILDREN AND ADULTS WERE INCLUDED IN THE STUDY AN INDEXED STENT LENGTH, CORRESPONDING TO THE LENGTH OF THE STENT IN MILLIMETRES DIVIDED BY THE PATIENT'S HEIGHT IN METERS, WAS CALCULATED FOR USE IN THE STATISTICAL ANALYSIS THE INDICATION FOR STENTING WAS NATIVE COA OR RECOA . THREE PATIENTS UNDERWENT TWO CATHETERIZATION PROCEDURES TO ACHIEVE A SATISFACTORY HEMODYNAMIC OUTCOME (TRANSAORTIC GRADIENT 10MM HG). MEDIAN STENT LENGTH EMPLOYED WAS 29 MM. OF THE STENTS USED IN THE PROCEDURES, 19 PATIENTS WERE TREATED WITH AN INTRASTENT MAX LD. TWO SERIOUS COMPLICATIONS LINKED TO THE CATHETERIZATION PROCEDURE WERE OBSERVED: MIGRATION OF THE STENT AND CEREBELLAR STROKE. FOURTEEN OF THE PATIENTS (46.7%) HAD HT AFTER STENTING, THREE OF WHOM WERE CHILDREN.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 219183 | INTRASTENT MAX LD | CATHETER, BILIARY, DIAGNOSTIC | FGE | COVIDIEN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 19 YR |