ETHILON NYLON SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2019-79191
- Event Type
- Injury
- Date Received
- March 1, 2019
- Report Date
- February 4, 2019
- Manufacturer
- ETHICON INC.
- Product Code
- GAR
- PMA / PMN Number
- K946173
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: ACADEMIC EMERGENCY MEDICINE. 2004; 11: 730¿735. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE "TITLE: A RANDOMIZED, CONTROLLED TRIAL COMPARING LONG-TERM COSMETIC OUTCOMES OF TRAUMATIC PEDIATRIC LACERATIONS REPAIRED WITH ABSORBABLE PLAIN GUT VERSUS NONABSORBABLE NYLON SUTURES". AUTHORS: HELEN KAROUNIS, MDCM; SERGE GOUIN, MDCM; HARLEY EISMAN, MDCM; DOMINIC CHALUT, MDCM; HELENE PELLETIER, RN, BSC; BRUCE WILLIAMS, MD. CITATION: ACADEMIC EMERGENCY MEDICINE. 2004; 11: 730¿735. THE OBJECTIVES OF THE STUDY WAS TO SHOW THAT THE USE OF ABSORBABLE SUTURES IN PEDIATRIC TRAUMATIC LACERATIONS AFFORDS GOOD LONG-TERM COSMESIS AND NO INCREASE IN COMPLICATIONS WHEN COMPARED WITH WOUNDS SUTURED WITH NON-ABSORBABLE SUTURES. THIS WAS A RANDOMIZED CLINICAL TRIAL CONDUCTED IN A PEDIATRIC EMERGENCY DEPARTMENT OF 95 PATIENTS WITH LACERATIONS AND WERE INCLUDED IN THE STUDY. OF WHICH, 50 PATIENTS WERE RANDOMIZED TO GROUP A (20 FEMALE AND 30 MALE PATIENTS; MEDIAN AGE: 8.1 YEARS) AND 45 PATIENTS WERE RANDOMIZED TO GROUP NA (17 FEMALE AND 28 MALE PATIENTS; MEDIAN AGE: 9.5 YEARS). GROUP A PATIENTS RECEIVED ABSORBABLE PLAIN CATGUT SUTURES (ETHICON) AND PATIENTS IN GROUP NA RECEIVED NON-ABSORBABLE NYLON SUTURES (ETHICON). IN GROUP A, REPORTED COMPLICATIONS INCLUDED DEHISCENCE (2%) AND SURGICAL SCAR (N-2) WHICH REQUIRED SURGICAL SCAR REVISION. IN GROUP NA, REPORTED COMPLICATIONS INCLUDED DEHISCENCE (11%), INFECTION (2%), AND SURGICAL SCAR (N-1) WHICH REQUIRED SURGICAL SCAR REVISION. THE STUDY SUGGESTS THAT THE USE OF PLAIN GUT ABSORBABLE SUTURE MATERIAL IN PEDIATRIC TRAUMATIC LACERATIONS AFFORDS GOOD LONG-TERM COSMESIS AND SIMILAR COMPLICATION RATES AS IN TRAUMATIC WOUNDS REPAIRED WITH NONABSORBABLE, NYLON SUTURE MATERIAL.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 174355 | ETHILON NYLON SUTURE UNKNOWN PRODUCT | SUTURE, NONABSORBABLE, SYNTHETIC | GAR | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |