UNKNOWN MAE GENERATOR
Report
- Report Number
- 1226420-2019-00016
- Event Type
- Injury
- Date Received
- February 8, 2019
- Date of Event
- January 10, 2019
- Report Date
- February 8, 2019
- Manufacturer
- MEDTRONIC ADVANCED ENERGY, LLC
- Product Code
- GEI
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NH, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
PRODUCT EVENT: (B)(6). PATIENT INFORMATION UNABLE TO BE OBTAINED DESPITE A GOOD FAITH EFFORT MADE TO OBTAIN THE INFORMATION FROM THE CUSTOMER. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
ARTICLE TITLE: COST-EFFECTIVENESS OF A RADIO FREQUENCY HEMOSTATIC SEALER (RFHS) IN ADULT SPINAL DEFORMITY SURGERY METHODS: IN AN OBSERVATIONAL COHORT STUDY, WE COMPARED TRANSFUSION REQUIREMENTS IN 30 PATIENTS UNDERGOING SURGERY FOR ADULT SPINAL DEFORMITY. USING THE RFHS WITH THAT OF A HISTORICAL CONTROL GROUP OF 30 PATIENTS IN WHICH TRADITIONAL HEMOSTASIS WAS OBTAINED WITH BIPOLAR ELECTROCAUTERY AND MATCHED THEM FOR BLOOD LOSS RELATED VARIABLES. TOTAL EXPENSE TO THE HOSPITAL FOR THE RFHS, LABORATORY EXPENSES, AND BLOOD TRANSFUSIONS WAS USED FOR COST CALCULATIONS. THE INCREMENTAL COST-EFFECTIVENESS RATIO WAS CALCULATED USING THE NUMBER OF BLOOD TRANSFUSIONS AVOIDED AS THE EFFECTIVENESS PAYOFF. RESULTS: USING A MULTIVARIABLE LINEAR REGRESSION MODEL, WE FOUND THAT ONLY ESTIMATED BLOOD LOSS (EBL) WAS AN INDEPENDENT SIGNIFICANT PREDICTOR OF TRANSFUSION REQUIREMENT IN BOTH GROUPS. WE EVALUATED THE VARIABLES OF AGE, EBL, TIME DURATION OF SURGERY, PREOPERATIVE HEMOGLOBIN, HEMOGLOBIN NADIR DURING SURGERY, BODY MASS INDEX, LENGTH OF STAY, AND NUMBER OF LEVELS OPERATED ON. MEAN EBL WAS GREATER IN THE CONTROL GROUP (2201 VS. 1416 ML, P [ 0.0099). THE NUMBER OF TRANSFUSIONS ALSO WAS GREATER IN THE CONTROL GROUP (14.5 VS. 6.5, P[0.0008). IN THE COST-EFFECTIVENESS ANALYSIS, WE FOUND THAT THE RFHS COST $108 MORE (COMPARED WITH NOT USING THE RFHS) TO AVOID 1 UNIT OF BLOOD TRANSFUSION. THE RFHS GROUP MEAN: 64.7 YEARS OF AGE ADVERSE EFFECTS: NUMBER OF BLOOD PRODUCT TRANSFUSED: 6.5 MEAN THE RFHS GROUP: OUT OF 21 FEMALES, 2 PATIENT'S EXPERIENCED AN INFECTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 113884 | UNKNOWN MAE GENERATOR | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES | GEI | MEDTRONIC ADVANCED ENERGY, LLC | MAE UNK GEN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |