FDA Adverse Event Malfunction Summary report: N

OSCILLATING SAW ATCH, LARGE, WITH KEY

MDR report key: 8305946 · Received February 5, 2019

Report

Report Number
8030965-2019-60425
Event Type
Malfunction
Date Received
February 5, 2019
Date of Event
January 9, 2019
Report Date
January 9, 2019
Manufacturer
DEPUY SYNTHES PRODUCTS LLC
Product Code
GFA
UDI-DI
7611819996069
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MA, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. ADDITIONAL NARRATIVE: THE DATE RETURNED TO MANUFACTURER WAS DOCUMENTED AS JANUARY 21, 2019 ON THE INITIAL REPORT. THIS DATE HAS BEEN UPDATED TO JANUARY 28, 2019. THE MANUFACTURING SITE NAME WAS DOCUMENTED AS OBERDORF SYNTHES PRODUKTIONS GMBH (OBERDORF) IN THE INITIAL REPORT. THIS HAS BEEN UPDATED TO SYNTHES PRODUKTIONS GMBH (WALDENBURG). PLEASE NOTE THAT THE CONTACT OFFICE NAME/ADDRESS HAVE BEEN UPDATED ACCORDINGLY TO REFLECT THE CORRECTED MANUFACTURING FACILITY. DEVICE EVALUATION: THIS DEVICE WAS RETURNED FOR SERVICE; HOWEVER, DID NOT MEET MANUFACTURING SPECIFICATIONS DURING PRE-REPAIR ASSESSMENT. DURING REPAIR, IT WAS DETERMINED THAT THE BEARINGS OF THE ATTACHMENT DEVICE WERE WORN OUT. IT WAS NOTED THAT THE NEEDLE BEARING WAS DEFECTIVE. IT WAS FURTHER DETERMINED THAT THE DEVICE FAILED PRETEST FOR CHECK OSCILLATION FREQUENCY. THEREFORE, THE REPORTED CONDITION WAS CONFIRMED. THE ASSIGNABLE ROOT CAUSE WAS DETERMINED TO BE DUE TO WEAR FROM NORMAL USE OVER TIME. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

Additional Manufacturer Narrative · 1

THE ACTUAL DEVICE HAS BEEN RETURNED AND IS CURRENTLY PENDING EVALUATION. ONCE THE EVALUATION OF THE DEVICE HAS BEEN COMPLETED, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SENT ACCORDINGLY.

Description of Event or Problem · 1

IT WAS REPORTED THAT DURING AN UNSPECIFIED VETERINARY SURGICAL PROCEDURE IT WAS OBSERVED THAT THE OSCILLATING SAW ATTACHMENT WITH KEY DEVICE WAS RUNNING SLUGGISHLY. DURING IN-HOUSE ENGINEERING EVALUATION IT WAS OBSERVED THAT THE UNIT WAS RUNNING SLOW AND THEN SPED UP (THE SPEED WAS NOT CONSISTENT), AND THE ATTACHMENT WAS GETTING HOT. THERE WAS NO HUMAN PATIENT INVOLVEMENT AS THIS WAS A VETERINARY PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
98972 OSCILLATING SAW ATCH, LARGE, WITH KEY BLADE, SAW, GENERAL AND PLASTIC SURGERY, SURGICAL GFA DEPUY SYNTHES PRODUCTS LLC N/A 7611819996069

Patients

Seq Age Sex Outcome Treatment
1