5.5 HEALIX ADVANCE KNTLSS BR
Report
- Report Number
- 1221934-2018-53449
- Event Type
- Malfunction
- Date Received
- January 23, 2019
- Date of Event
- February 23, 2017
- Report Date
- February 23, 2017
- Manufacturer
- DEPUY MITEK LLC US
- Product Code
- MAI
- UDI-DI
- 10886705023479
- PMA / PMN Number
- K130917
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- OTHER
Narratives
IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY. UDI: (B)(4). THE COMPLAINT DEVICE IS NOT BEING RETURNED, THEREFORE UNAVAILABLE FOR A PHYSICAL EVALUATION. A REVIEW INTO THE DEPUY MITEK COMPLAINTS SYSTEM REVEALED NO OTHER COMPLAINTS FOR THIS LOT OF DEVICES THAT WERE RELEASED TO DISTRIBUTION. WE CANNOT DISCERN A ROOT CAUSE FOR THE REPORTED FAILURE MODE. AT THIS POINT IN TIME, NO CORRECTIVE ACTION IS REQUIRED AND NO FURTHER ACTION IS WARRANTED. THIS FILE WILL REMAIN RECEPTIVE TO ANY POTENTIAL FORTHCOMING INFORMATION RECEIVED THAT IS PERTINENT AND GERMANE TO THIS ISSUE. A NON-CONFORMANCE SEARCH WAS PERFORMED FOR THIS PRODUCT CODE 222331-LOT #L175048 COMBINATION AND NO NON-CONFORMANCES WERE IDENTIFIED. NO FURTHER INFORMATION REGARDING THE TECHNIQUE OR INSTRUMENTS USED HAS BEEN PROVIDED TO DETERMINE A ROOT CAUSE FOR THIS FAILURE. IF ANY ADDITIONAL INFORMATION IS OBTAINED, THIS COMPLAINT WILL BE RE-OPENED TO CAPTURE THAT INFORMATION. AT THIS POINT IN TIME, NO CORRECTIVE ACTION IS REQUIRED, AND NO FURTHER ACTION IS WARRANTED. HOWEVER, DEPUY MITEK WILL CONTINUE TO TRACK ANY RELATED COMPLAINTS WITHIN THIS DEVICE FAMILY AS A MEANS OF MONITORING THE EXTENT WITH WHICH THIS COMPLAINT IS OBSERVED IN THE FIELD. THIS REPORT IS BEING FILED FROM THE (B)(4) AS REQUIRED UNDER MITEK'S CORRECTIVE AND PREVENTATIVE ACTIONS (CAPA) TO FILE USA FDA MDR MISSED MALFUNCTIONS.
THIS IS REPORT 2 OF 2 FOR THE SAME EVENT. IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT DURING ROTATOR CUFF REPAIR SURGICAL PROCEDURE, THE SURGEON TRIED TO INSERT THE REPORTED 222330 4.75 HEALIX ANCHOR INTO THE BONE HOLE. IT WAS REPORTED THAT WHILE THE SURGEON WAS INSERTING FOUR POLYAMIDE SUTURES (NAMED ¿SURGILON¿) INTO THE ANCHOR, IT CRACKED AND BROKE. IT WAS REPORTED THAT THE SURGEON REPLACED THE DEVICE WITH THE REPORTED 222331 5.5 HEALIX ANCHOR. IT WAS REPORTED THAT THE SURGEON TRIED TO THREAD FOUR FIBERWIRE SUTURES INTO THE ANCHOR. IT WAS REPORTED THAT THE SUTURES DID NOT GO THROUGH THE ANCHOR. IT WAS REPORTED THAT THE SURGEON BROKE THE ANCHOR, SECURED THE SUTURES, AND TOOK OUT THE ANCHOR. THIS TIME HE DID NOT RE-THREAD ALL THE SUTURES ALL AT ONCE. IT WAS REPORTED THAT IT TOOK A FEW TIMES TO RE-THREAD ALL THE SUTURES. IT WAS REPORTED THAT THE SURGEON COMPLETED THE SUTURE BRIDGING. IT WAS REPORTED THAT THE DEVICES WERE BRAND NEW AND THEIR FIRST USE WHEN THE ISSUE OCCURRED. THE SURGERY WAS COMPLETED WITH A 10-MINUTE DELAY. THERE WAS NO HARM TO THE PATIENT. THERE IS NO INFORMATION IF THE ORIGINAL BONE HOLE WAS USED TO COMPLETE THE PROCEDURE OR IF ANY ADDITIONAL DAMAGE WAS MADE TO THE PATIENT DUE TO THIS FAILURE. IT WAS UNKNOWN WHAT SIZE SUTURE WAS USED. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 64208 | 5.5 HEALIX ADVANCE KNTLSS BR | SOFT-TISSUE ANCHOR, BIOABSORBABLE | MAI | DEPUY MITEK LLC US | L175048 | 10886705023479 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |