YUNO OTN, SFC EC
Report
- Report Number
- 8010652-2019-00001
- Event Type
- Malfunction
- Date Received
- January 9, 2019
- Date of Event
- December 13, 2018
- Report Date
- March 12, 2019
- Manufacturer
- HOLGER ULLRICH
- Product Code
- FQO
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET GMBH, KEHLER STRASSE 31, RASTATT, GERMANY 76437. EXEMPTION # E2018004. GETINGE USA SALES, LLC. 45 BARBOUR POND DRIVE WAYNE, NJ 07470. CONTACT PERSON: (B)(4). THE MALFUNCTION COULD BE TRACED BACK TO THE TABLES CONTROL BOARD. THE AFFECTED BOARD WAS RETURNED FOR FURTHER INVESTIGATION. THIS INVESTIGATION REVEALED THAT A SHORT CIRCUIT ON ONE CAPACITOR HAD CAUSED THE ISSUE. THE AFFECTED BOARD WAS MANUFACTURED IN 2013. THE CUSTOMER CONFIRMED IT WAS ON STOCK FOR FOUR YEARS AND MOUNTED TO THE AFFECTED TABLE IN AUGUST 2017. IT CANNOT BE DETERMINED WHAT EXACTLY CAUSED THE MENTIONED SHORT CIRCUIT. THIS MIGHT BE DUE TO A MISTAKE AT THE SUPPLIERS' OR SUBSUPPLIERS' SIDE. THE AFFECTED CAPACITOR COULD HAVE BEEN DELIVERED FAULTY, YET FUNCTIONAL OR COULD HAVE BEEN DAMAGED WHEN MOUNTED TO THE BOARD (SUPPLIER). ANOTHER ROOT CAUSE FOR THIS ISSUE COULD BE RELATED TO ELECTROMAGNETIC COMPATIBILITY (EMC). OTHER DEVICES IN THE ROOM MIGHT CAUSE A CURRENT IN THE CABLES OF THE REMOTE CONTROL. THIS CURRENT COULD DAMAGE THE CAPACITOR. MAQUET GMBH PROVIDES PRODUCT FAILURE INVESTIGATION, ANALYSIS AND RESOLUTION FOR THE DEVICE DESCRIBED IN THIS REPORT.
GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET GMBH, KEHLER STRASSE 31, RASTATT, GERMANY 76437. EXEMPTION # E2018004. GETINGE USA SALES, LLC, 45 BARBOUR POND DRIVE, WAYNE, NJ 07470. CONTACT PERSON: (B)(4). THE INVESTIGATION IS STILL ONGOING.
MANUFACTURER REFERENCE #: (B)(4).
IT WAS REPORTED THAT BEFORE SURGERY, WHEN THE PATIENT WAS ON THE TABLE, THE OPERATING TABLE WAS NOT FUNCTIONING. THE START OF THE PROCEDURE WAS DELAYED. THE SURGERY WAS PERFORMED AND FINISHED ON THE AFFECTED TABLE. NO INJURY HAS BEEN REPORTED. MFR REFERENCE # (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 25201 | YUNO OTN, SFC EC | TABLE, OPERATING-ROOM, AC-POWERED | FQO | HOLGER ULLRICH | 143301BO |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |