FDA Adverse Event Malfunction Summary report: N

YUNO OTN, SFC EC

MDR report key: 8232487 · Received January 9, 2019

Report

Report Number
8010652-2019-00001
Event Type
Malfunction
Date Received
January 9, 2019
Date of Event
December 13, 2018
Report Date
March 12, 2019
Manufacturer
HOLGER ULLRICH
Product Code
FQO
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET GMBH, KEHLER STRASSE 31, RASTATT, GERMANY 76437. EXEMPTION # E2018004. GETINGE USA SALES, LLC. 45 BARBOUR POND DRIVE WAYNE, NJ 07470. CONTACT PERSON: (B)(4). THE MALFUNCTION COULD BE TRACED BACK TO THE TABLES CONTROL BOARD. THE AFFECTED BOARD WAS RETURNED FOR FURTHER INVESTIGATION. THIS INVESTIGATION REVEALED THAT A SHORT CIRCUIT ON ONE CAPACITOR HAD CAUSED THE ISSUE. THE AFFECTED BOARD WAS MANUFACTURED IN 2013. THE CUSTOMER CONFIRMED IT WAS ON STOCK FOR FOUR YEARS AND MOUNTED TO THE AFFECTED TABLE IN AUGUST 2017. IT CANNOT BE DETERMINED WHAT EXACTLY CAUSED THE MENTIONED SHORT CIRCUIT. THIS MIGHT BE DUE TO A MISTAKE AT THE SUPPLIERS' OR SUBSUPPLIERS' SIDE. THE AFFECTED CAPACITOR COULD HAVE BEEN DELIVERED FAULTY, YET FUNCTIONAL OR COULD HAVE BEEN DAMAGED WHEN MOUNTED TO THE BOARD (SUPPLIER). ANOTHER ROOT CAUSE FOR THIS ISSUE COULD BE RELATED TO ELECTROMAGNETIC COMPATIBILITY (EMC). OTHER DEVICES IN THE ROOM MIGHT CAUSE A CURRENT IN THE CABLES OF THE REMOTE CONTROL. THIS CURRENT COULD DAMAGE THE CAPACITOR. MAQUET GMBH PROVIDES PRODUCT FAILURE INVESTIGATION, ANALYSIS AND RESOLUTION FOR THE DEVICE DESCRIBED IN THIS REPORT.

Additional Manufacturer Narrative · 0

GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET GMBH, KEHLER STRASSE 31, RASTATT, GERMANY 76437. EXEMPTION # E2018004. GETINGE USA SALES, LLC, 45 BARBOUR POND DRIVE, WAYNE, NJ 07470. CONTACT PERSON: (B)(4). THE INVESTIGATION IS STILL ONGOING.

Description of Event or Problem · 0

MANUFACTURER REFERENCE #: (B)(4).

Description of Event or Problem · 0

IT WAS REPORTED THAT BEFORE SURGERY, WHEN THE PATIENT WAS ON THE TABLE, THE OPERATING TABLE WAS NOT FUNCTIONING. THE START OF THE PROCEDURE WAS DELAYED. THE SURGERY WAS PERFORMED AND FINISHED ON THE AFFECTED TABLE. NO INJURY HAS BEEN REPORTED. MFR REFERENCE # (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
25201 YUNO OTN, SFC EC TABLE, OPERATING-ROOM, AC-POWERED FQO HOLGER ULLRICH 143301BO

Patients

Seq Age Sex Outcome Treatment
1 Other