FDA Adverse Event Injury Summary report: N

SILK SUTURE UNKNOWN PRODUCT

MDR report key: 8224337 · Received January 7, 2019

Report

Report Number
2210968-2019-78249
Event Type
Injury
Date Received
January 7, 2019
Report Date
December 20, 2018
Manufacturer
ETHICON INC.
Product Code
GAP
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IS
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: INTERNATIONAL JOURNAL OF GYNECOLOGY AND OBSTETRICS (2007) 96, 16¿19; DOI:10.1016/J.IJGO.2006.09.002. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE "TITLE: FAVORABLE OUTCOME FOLLOWING EMERGENCY SECOND TRIMESTER CERCLAGE". AUTHORS: A. DEBBY, O. SADAN, M. GLEZERMAN, A. GOLAN. CITATION: INTERNATIONAL JOURNAL OF GYNECOLOGY AND OBSTETRICS (2007) 96, 16¿19; DOI:10.1016/J.IJGO.2006.09.002. THE AIM OF THIS RETROSPECTIVE STUDY WAS TO COMPARE THE RESULTS OF PREGNANCY AND NEONATAL OUTCOME OF CERVICAL CERCLAGE PERFORMED DURING THE SECOND TRIMESTER OF PREGNANCY IN DIFFERENT EMERGENCY SITUATIONS: WITH BULGING OF MEMBRANES AND WITHOUT. DURING THE 15 YEARS PERIOD, BETWEEN 1990 AND 2005, 99 PATIENTS UNDERWENT AN EMERGENCY SECOND TRIMESTER CERCLAGE AND WERE DIVIDED INTO TWO GROUPS: ALL PATIENTS PRESENTED WITH CERVICAL EFFACEMENT AND DILATION WITHOUT BULGING OF MEMBRANES INTO THE VAGINA (GROUP 1; N=75) AND ALL PATIENTS HAD A DILATED AND EFFACED CERVIX WITH BULGING OF MEMBRANES INTO THE VAGINA IN AN HOURGLASS FORMATION (GROUP 2; N=24). IN BOTH GROUPS, THE CERVICAL SUTURE WAS PLACED IN THE MCDONALD METHOD USING DOUBLE SILK NO 4 (MERSILK, ETHICON, JOHNSON AND JOHNSON, U.S.A) IN THE FIRST 8 YEARS OF THE STUDY AND THEN REPLACED BY MERCILEN SUTURE. COMPLICATION OF THE PROCEDURE INCLUDED PREMATURE CONTRACTIONS (N=19), ABRUPTIO PLACENTA (N=5), REPEAT CERCLAGE (N=6), PRETERM PREMATURE RUPTURE OF MEMBRANES (N=20) AND CHORIOAMNIONITIS (N=17). THE RESULTS OF THE PRESENT STUDY DEMONSTRATED A FAVORABLE PROLONGATION OF PREGNANCY AND NEONATAL OUTCOME IN EMERGENCY SECOND TRIMESTER CERCLAGE EVEN WHEN BULGING OF THE MEMBRANES EXISTS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
15754 SILK SUTURE UNKNOWN PRODUCT SUTURE, NONABSORBABLE, SILK GAP ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention