Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS (ETHIBOND SUTURE) INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCTS (ETHIBOND SUTURE) USED IN THIS PROCEDURE? CITATION: INTERNATIONAL ORTHOPAEDICS (SICOT). 2016; 40: 569¿577. DOI: 10.1007/S00264-015-2950-0.
IT WAS REPORTED VIA JOURNAL ARTICLE "TITLE : CLINICAL AND RADIOLOGICAL OUTCOMES OF UNSTABLE PROXIMAL HUMERAL FRACTURES TREATED WITH A LOCKING PLATE AND FIBULAR STRUT ALLOGRAFT". AUTHOR: KARNAV PANCHAL1 & JAE-JUNG JEONG1 & SANG-EUN PARK1 & WEON-YOO KIM1 & HYUNG-KI MIN1 & JU-YEONG KIM1 & JONG-HUN JI1. CITATION: INTERNATIONAL ORTHOPAEDICS (SICOT). 2016; 40: 569¿577. DOI: 10.1007/S00264-015-2950-0. THE PURPOSE OF THE STUDY WAS TO EVALUATE THE CLINICAL AND RADIOLOGICAL OUTCOMES OF UNSTABLE PROXIMAL HUMERAL FRACTURES (PHFS) TREATED WITH A LOCKING PLATE AND FIBULAR STRUT ALLOGRAFT. THIS STUDY INCLUDED 36 PATIENTS (7 MEN AND 29 WOMEN; AGE RANGE: 22 TO 94 YEARS OLD) WITH UNSTABLE PHFS WITH MEDIAL COLUMN DISRUPTION. ALL PATIENTS WERE TREATED WITH OPEN REDUCTION AND INTERNAL FIXATION USING A LOCKING PLATE AND FIBULAR STRUT ALLOGRAFT. DURING THE SURGICAL PROCEDURE, THE LONG HEAD OF THE BICEPS WAS ISOLATED AND WAS DETACHED PROXIMALLY. THE GREATER TUBEROSITY (GT) FRACTURE FRAGMENT WAS RETRACTED BY PLACING ETHIBOND 2-0 SUTURES (ETHICON) THROUGH THE BONE-TENDON JUNCTION OF THE ROTATOR CUFF MUSCLES. THE INSERTED FIBULAR GRAFT MAINTAINED A GOOD ALIGNMENT OF THE FRACTURE, AND THE LOCKING PLATE WAS EASILY APPLIED TO THE FRACTURE SITE. ETHIBOND 2-0 SUTURES (ETHICON) WERE USED TO ATTACH THE HUMERAL HEAD FRACTURE FRAGMENT TO THE LESSER TUBEROSITY AND ALSO THE LESSER TUBEROSITY TO THE GREATER TUBEROSITY. CHIP BONE ALLOGRAFT COULD BE USED IN THE BONE DEFECT SITE. USING ETHIBOND 2-0 SUTURES (ETHICON), METICULOUS REPAIR OF THE ROTATOR CUFF TO THE PLATE WAS CARRIED OUT. REPORTED COMPLICATIONS INCLUDED VARUS COLLAPSE (N-2) WHICH REQUIRED FURTHER SURGICAL INTERVENTION, SUCH AS REFIXATION OR ARTHROPLASTY, BUT THEY BOTH REFUSED TO UNDERGO ANY TREATMENT, AVASCULAR NECROSIS OF THE HUMERAL HEAD (N-2) WHICH REQUIRED FURTHER SURGICAL INTERVENTION, SUCH AS REFIXATION OR ARTHROPLASTY, BUT THEY BOTH REFUSED TO UNDERGO ANY TREATMENT, ADHESIVE CAPSULITIS (N-2) WHICH REQUIRED PLATE REMOVAL AND SHOWED SATISFACTORY FINAL OUTCOME. THE STUDY DEMONSTRATES THAT UNSTABLE, COMPLEX PHFS WITH MEDIAL COMMINUTION CAN BE RELIABLY TREATED WITH JOINT PRESERVING TECHNIQUES USING FIBULAR ALLOGRAFTS AND LOCKING PLATES TO RESTORE THE INTEGRITY OF THE MEDIAL COLUMN, SUPPORT THE HUMERAL HEAD, AND MAINTAIN REDUCTION UNTIL THE FRACTURE CAN HEAL. A SECOND COLUMN OF SUPPORT IS EASILY ESTABLISHED: THE STABILITY OF THE RECONSTRUCTION HAS IMPROVED, AND REDUCTION IS MAINTAINED. THIS MINIMIZES THE MOST FREQUENT COMPLICATIONS REPORTED WITH PROXIMAL HUMERAL LOCKING PLATES AND ALLOWS FOR EARLY AND AGGRESSIVE REHABILITATION WITH GREATER PATIENT SATISFACTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1045216 | ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN | SUTURE, NONABSORBABLE, SYNTHETIC | GAT | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |