NEU_INS_STIMULATOR
Report
- Report Number
- 3007566237-2018-03717
- Event Type
- Injury
- Date Received
- December 27, 2018
- Date of Event
- September 10, 2018
- Report Date
- December 27, 2018
- Manufacturer
- MEDTRONIC NEUROMODULATION
- Product Code
- LNQ
- PMA / PMN Number
- P080025
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FI
- Reporter Occupation
- OTHER
Narratives
PLEASE NOTE THAT THIS DATE IS BASED OFF OF THE DATE THAT THE ARTICLE WAS ACCEPTED FOR PUBLICATION AS THE EVENT DATES WERE NOT PROVIDED IN THE PUBLISHED LITERATURE. CONCOMITANT MEDICAL PRODUCTS: PRODUCT ID: NEU_INS_STIMULATOR, LOT# UNKNOWN, PRODUCT TYPE: IMPLANTABLE NEUROSTIMULATOR. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
KIRSS, J., JR., PINTA, T., RAUTIO, T., VARPE, P., KAIRALUOMA, M., HYOTY, M., HURME, S., BOCKELMAN, C., KAIRALUOMA, V., SALMENKYLA, S., VICTORZON, M. IMPACT OF SPHINCTER LESIONS AND DELAYED SPHINCTER REPAIR ON SACRAL NEUROMODULATION TREATMENT OUTCOMES FOR FAECAL INCONTINENCE: RESULTS FROM A FINNISH NATIONAL COHORT STUDY. INT J COLORECTAL DIS. 2018;33(12):1709-1714. DOI: 10.1007/S00384-018-3161-0. SUMMARY: THE AIM OF THIS MULTICENTRE STUDY WAS TO ANALYSE THE EFFECTS OF PATENT SPHINCTER LESIONS AND PREVIOUS SPHINCTER REPAIR ON THE RESULTS OF SACRAL NEUROMODULATION (SNM) TREATMENT ON PATIENTS WITH FAECAL INCONTINENCE (FI). PATIENTS EXAMINED BY ENDOANAL ULTRASOUND (EAUS) WITH FI AS THE INDICATION FOR SNM TREATMENT WERE INCLUDED IN THE STUDY. DATA WAS COLLECTED FROM ALL THE CENTRES PROVIDING SNM TREATMENT IN FINLAND AND ANALYSED FOR DIFFERENCES IN TREATMENT OUTCOMES. A TOTAL OF 237 PATIENTS TREATED FOR INCONTINENCE WITH SNM HAD BEEN EXAMINED BY EAUS. OF THESE PATIENTS, 33 HAD A HISTORY OF PREVIOUS DELAYED SPHINCTER REPAIR. A PATENT SPHINCTER LESION WAS DETECTED BY EAUS IN 128 PATIENTS. THE EAUS FINDING DID NOT INFLUENCE THE SNM TEST PHASE OUTCOME (P = 0.129) OR THE FINAL TREATMENT OUTCOME (P = 0.233). PATIENT¿S HISTORY OF PRIOR SPHINCTER REPAIR DID NOT HAVE A SIGNIFICANT EFFECT ON THE SNM TEST (P = 0.425) OR FINAL TREATMENT OUTCOME (P = 0.442). RESULTS OF OUR STUDY INDICATE THAT A SPHINCTER LESION OR PREVIOUS SPHINCTER REPAIR HAS NO SIGNIFICANT EFFECT ON THE OUTCOME OF SNM TREATMENT. OUR DATA SUGGESTS THAT DELAYED SPHINCTER REPAIR PRIOR TO SNM TREATMENT INITIATION FOR FI IS NOT NECESSARY. REPORTED EVENTS: 15 PATIENTS EXPERIENCED AN INFECTION DURING SNM TESTING. (PLI 10).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1040409 | NEU_INS_STIMULATOR | INTESTINAL STIMULATOR | LNQ | MEDTRONIC NEUROMODULATION | NEU_INS_STIMULATOR | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |