FDA Adverse Event Injury Summary report: N

SYSTEM 9733560 FUSION EM

MDR report key: 8157805 · Received December 12, 2018

Report

Report Number
1723170-2018-06170
Event Type
Injury
Date Received
December 12, 2018
Date of Event
August 22, 2018
Report Date
December 10, 2018
Manufacturer
MEDTRONIC NAVIGATION, INC
Product Code
HAW
PMA / PMN Number
K001284
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MI, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

PATIENT WEIGHT NOT AVAILABLE FROM THE SITE. PLEASE NOTE THAT THIS DATE IS BASED OFF OF THE DATE OF PUBLICATION OF THE ARTICLE AS THE EVENT DATES WERE NOT PROVIDED IN THE PUBLISHED LITERATURE. SAYAL, N. R., KEIDER, E., <(>&<)> KORKIGIAN, S. (2018). VISUALIZED ETHMOID ROOF CEREBROSPINAL FLUID LEAK DURING FRONTAL BALLOON SINUPLASTY. EAR, NOSE <(>&<)> THROAT JOURNAL, 97(8), E34-E38. DOI:10.1177/014556131809700807. DEVICE LOT NUMBER, OR SERIAL NUMBER, UNAVAILABLE. UDI NOT AVAILABLE FOR THIS SYSTEM AT TIME OF FILING. THE DEVICE WAS NOT RETURNED, SO NO ANALYSIS WAS CONDUCTED. DEVICE MANUFACTURING DATE IS DEPENDENT ON LOT NUMBER/SERIAL NUMBER, THEREFORE, UNAVAILABLE. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

CITATION SAYAL, N. R., KEIDER, E., <(>&<)> KORKIGIAN, S. (2018). VISUALIZED ETHMOID ROOF CEREBROSPINAL FLUID LEAK DURING FRONTAL BALLOON SINUPLASTY. EAR, NOSE, THROAT JOURNAL, 97(8), E34-E38. DOI:10.1177/014556131809700807 ABSTRACT BALLOON SINUS DILATION (BSD) ISGENERALLY ACCEPTED AS A SAFE ALTERNATIVE TO TRADITIONAL SINUS SURGERY. IT IS A UNIQUE TECHNIQUE DESIGNED TO POTENTIALLY MINIMIZE COMPLICATIONS ASSOCIATED WITH TRADITIONAL FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS). WE PRESENT A CASE IN WHICH A 65-YEAR-OLD MAN EXPERIENCED A CEREBROSPINAL FLUID (CSF) LEAK IN THE ETHMOID ROOF THAT WAS VISUALIZED INSTANTLY AFTER BALLOON DILATION IN A REVISION SINUS SURGERY. IN THIS CASE REPORT, WE DISCUSS THE CAUSES OF CSF LEAKS AND EXPLAIN IN DETAIL THE IMMEDIATE ENDOSCOPIC REPAIR WITH A COLLAGEN MATRIX. ALSO, LITERATURE IS REVIEWED ON THE SAFETY OF BSD VERSUS TRADITIONAL FESS. POSTOPERATIVELY, THE PATIENT HAS BEEN WITHOUT CSF LEAK AND REMAINS SYMPTOM FREE. CSF LEAK IS A RARE BUT MAJOR COMPLICATION DURING BOTH FESS AND BSD. AS BSD USE INCREASES, ITS COMPLICATION PROFILE WILL BECOME CLEARER WHEN USED ALONE, IN CONJUNCTION WITH FESS, AND/OR DURING REVISION SURGERY. ALTHOUGH BSD IS CONSIDERED A BENIGN PROCEDURE, ONE SHOULD BE CAUTIOUS WHEN USING IT IN REVISION SINUS SURGERY. REPORTED EVENT A 65 YEAR OLD MAN WHO EXPERIENCED CEREBROSPINAL FLUID LEAK DURING THE SURGERY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
993924 SYSTEM 9733560 FUSION EM INSTRUMENT, STEREOTAXIC HAW MEDTRONIC NAVIGATION, INC 9733560

Patients

Seq Age Sex Outcome Treatment
1 65 YR Hospitalization| O