FDA Adverse Event Death Summary report: N

OXYGENATOR WITH INTEGRATED HEAT EXCHANGER

MDR report key: 8150941 · Received December 11, 2018

Report

Report Number
8010762-2018-00326
Event Type
Death
Date Received
December 11, 2018
Date of Event
November 26, 2018
Report Date
February 14, 2019
Manufacturer
MAQUET CARDIOPULMONARY AG
Product Code
DTZ
PMA / PMN Number
K101153
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

(B)(4). A FOLLOW-UP MEDWATCH WILL BE SUBMITTED WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE. (B)(4). DEVICE REQUESTED BUT NOT YET RECEIVED. REFERENCE EXEMPTION # E2018002.

Additional Manufacturer Narrative · 0

MAQUET MEDICAL SYSTEMS,USA(IMPORTER)SUBMITS THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET CARDIOPULMONARY AG KEHLER STRASSE 31, 76437 RASTATT, GERMANY. A FOLLOW-UP MEDWATCH WILL BE SUBMITTED WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE. REFERENCE EXEMPTION # E2018002. IMPORTER- (B)(4). MAQUET GMBH REQUESTED THE PRODUCT FOR INVESTIGATION IN THE LABORATORY OF THE MANUFACTURER. THE RETURNED OXYGENATOR WAS INVESTIGATED IN THE LABORATORY OF THE MANUFACTURER. A QUADROX-ID ADULT WITHOUT TUBING WAS RETURNED. THE SAMPLE WAS CONTAMINATED. THE VENTING MEMBRANE WAS BLOODY AND WAS SENT BACK WITHOUT SCREW CAP. OXYGENATOR WAS CLEANED WITH SODIUM HYPOCHLORITE. LEAK TEST ACCORDING LV 201 WAS PERFORMED. A LEAK AT THE VENTING MEMBRANE WAS DETECTED AND DOCUMENTED. THE DEAERATION MEMBRANE WAS CLOSED AND A LEAK TEST WAS CARRIED OUT AGAIN. NO FURTHER LEAKS COULD BE DETECTED. SINCE THE OXYGENATOR WAS RETURNED WITHOUT TUBING, THE READJUSTMENT TEST COULD NOT BE PERFORMED AND THE CAUSE OF THE FAILURE CANNOT BE DETERMINED. THUS THE REPORTED FAILURE "AIR IN THE SYSTEM" COULD NOT BE CONFIRMED. ACCORDING TO THE TERRITORY MANAGER FROM 2019-02-12 "THE YELLOW CAP OF THE VENTING MEMBRANE WAS ATTACHED TO THE VENTING CONNECTOR AT THE TIME OF THE EVENT", THEREFORE THE DETECTED LEAKAGE WHICH WAS FOUND IN THE LABORATORY DURING INVESTIGATION COULD NOT LEAD TO THE REPORTED FAILURE AND ADDITIONALLY NO EVIDENCE WAS PROVIDED THAT THIS FAILURE WAS NOTICED WITHIN THE INITIAL COMPLAINT REPORT. CLINICAL ASSESSMENT CREATED BY OUR THERAPY APPLICATION MANAGER ON 2019-02-13: "THERE IS CURRENTLY NO EVIDENCE THAT THE QUADROX USED CONTRIBUTED TO AIR PENETRATION INTO THE ECC SYSTEM. IT IS ASSUMED THAT THE INTENDED USE OF THE CLAIMED OXYGENATOR AT THE TIME OF THE EVENT WAS NOT RESTRICTED. THE DEVICE WAS USED IN CONJUNCTION WITH A MEDTRONIC TUBE SET. ACCORDING TO THE OPINION OF THE TERRITORY MANAGER, THE PATIENT DIED FROM AIR IN THE SYSTEM, WHICH PROBABLY ENTERED THE EXTRACORPOREAL CIRCULATION THROUGH THE CENTRAL VENOUS CATHETER (CVC). ACCORDING TO THE CUSTOMER, THE OPINION IS THAT THE OXYGENATOR DID NOT TRIGGER AIR EMBOLIZATION. THESE TWO REPRESENTATIONS SUPPORT THE RATING GIVEN ABOVE." BASED ON THE INFORMATION AVAILABLE AT THIS TIME THE CAUSE OF THIS FAILURE WAS DETERMINED TO NOT BE ATTRIBUTED TO A DEVICE RELATED MALFUNCTION. SINCE NO DEVICE RELATED MALFUNCTION COULD BE CONFIRMED AND NO SYSTEMIC ISSUE COULD BE DETERMINED NO CORRECTIVE ACTION IS NEEDED AT THIS TIME. THE DATA IS ALSO BEING HANDLED THROUGH A DESIGNATED MAQUET CARDIOPULMONARY TRENDING AND APPLICABLE INVESTIGATION PROCESS. DUE TO THIS NO FURTHER INVESTIGATION INITIATIONS WILL BE COMPLETED AT THIS TIME.

Description of Event or Problem · 0

ACCORDING TO THE HOSPITAL: (B)(6) CALLED AND CLAIMED THE PATIENT HAD AN AIR EMBOLISM, MOST LIKELY CAUSED BY THE CENTRAL LINE, BUT HOSPITAL POLICY REQUIRED HIM TO CALL IN A COMPLAINT. HE DOES NOT "BELEIEVE" IT WAS THE OXYGENATOR. ADDITIONAL INFORMATION: PATIENT HAD AN AIR EMBOLISM WHICH LEAD TO HER DEATH. THE INCIDENT OCCURRED DURING USE. WAS THE OXYGENATOR EXCHANGE WITH A NEW ONE? YES. AIR WAS IN THE SYSTEM WHICH LED TO THE AIR EMBOLISM? AIR SOURCE WAS NOT IDENTIFIED WITH 100% CERTAINTY. MICRO AIR WAS ENTRAINED INTO THE SYSTEM WITH SUBSEQUENT DELIVERY TO THE PATIENT. THE USED TUBING SET WAS FROM MEDTRONIC. OXYGENATOR DOESN´T HAVE ANY OTHER ABNORMALITIES. INTERNAL REFERENCE: (B)(4).

Description of Event or Problem · 0

INTERNAL REFERENCE: (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
991560 OXYGENATOR WITH INTEGRATED HEAT EXCHANGER OXYGENATOR, CARDIOPULMONARY BYPASS DTZ MAQUET CARDIOPULMONARY AG HMOD 70000-USA #SQU 70124628

Patients

Seq Age Sex Outcome Treatment
1 Death