MESH SOFRADIM - PARIETEX¿ OPTIMIZED COMPOSITE MESH
Report
- Report Number
- 9615742-2018-02734
- Event Type
- Injury
- Date Received
- December 9, 2018
- Report Date
- December 17, 2025
- Manufacturer
- SOFRADIM PRODUCTION SAS
- Product Code
- FTL
- UDI-DI
- 10884521165724
- PMA / PMN Number
- K142908
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- 003
Narratives
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
THIS INFORMATION WAS RECEIVED AS A PART OF AN EXTENSIVE MESH LITIGATION SUBMISSION TO MEDTRONIC. THE FDA WAS NOTIFIED OF THIS LARGE COMPLAINT RECEIPT. DUE TO THE VOLUME OF COMPLAINT INFORMATION RECEIVED BY MEDTRONIC, THIS RESULTED IN A REPORT BEYOND THE 30 DAY TARGET. CONCOMITANT MEDICAL PRODUCTS: (BARD PERFIX PLUG; PRODUCT ID: 0112960, LOT#: HUYH014). (B)(4). IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
THIS INFORMATION WAS RECEIVED AS A PART OF AN EXTENSIVE MESH LITIGATION SUBMISSION TO MEDTRONIC. THE FDA WAS NOTIFIED OF THIS LARGE COMPLAINT RECEIPT. DUE TO THE VOLUME OF COMPLAINT INFORMATION RECEIVED BY MEDTRONIC, THIS RESULTED IN A REPORT BEYOND THE 30 DAY TARGET. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
ADDITIONAL INFORMATION: A4, B5, B7, H6 (IME, IMF CODES). MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
THE PATIENT¿S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL AND RIGHT INGUINAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, SEVERE ADHESIONS, RECURRENCE, MESH ADHERENT TO SMALL BOWEL, CHOLELITHIASIS, AND FASCIAL DEFECTS WHERE SUTURES PULLED THROUGH. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, CHOLECYSTECTOMY, MESH REMOVAL, AND HERNIA REPAIR WITH NEW MESH. THE DEVICE HAD BEEN USED WITH A BARD PERFIX PLUG; PRODUCT ID 0112960, LOT NUMBER HUYH0142.
THE PATIENT¿S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A RIGHT INGUINAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, SEVERE ADHESIONS, RECURRENCE, MESH ADHERENT TO SMALL BOWEL, CHOLELITHIASIS, AND FASCIAL DEFECTS WHERE SUTURES PULLED THROUGH. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY AND A CHOLECYSTECTOMY. THE DEVICE HAD BEEN USED WITH A BARD PERFIX PLUG; PRODUCT ID 0112960, LOT NUMBER HUYH0142.
THE PATIENT¿S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL AND RIGHT INGUINAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, SEVERE ADHESIONS, RECURRENCE, MESH ADHERENT TO SMALL BOWEL, CHOLELITHIASIS, FASCIAL DEFECTS WHERE SUTURES PULLED THROUGH, INFECTION, OBSTRUCTIONS, DISCOMFORT, BOWEL CRAMPS, CONSTIPATION, DIARRHEA, AND IRREGULAR BOWEL FUNCTION. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, CHOLECYSTECTOMY, MESH REMOVAL, HERNIA REPAIR WITH NEW MESH, AND MEDICATION.
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
THE PATIENT¿S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, SEVERE ADHESIONS, RECURRENCE, MESH ADHERENT TO SMALL BOWEL, CHOLELITHIASIS, AND FASCIAL DEFECTS WHERE SUTURES PULLED THROUGH. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY AND A CHOLECYSTECTOMY. THE DEVICE HAD BEEN USED WITH A BARD PERFIX PLUG; PRODUCT ID: 0112960, LOT NUMBER HUYH0142.
THE PATIENT¿S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A RIGHT INGUINAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, SEVERE ADHESIONS, RECURRENCE, AND MESH ADHERENT TO SMALL BOWEL. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 984846 | MESH SOFRADIM - PARIETEX¿ OPTIMIZED COMPOSITE MESH | MESH, SURGICAL, POLYMERIC | FTL | SOFRADIM PRODUCTION SAS | PCO8VP | POE0283 | 10884521165724 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Male | Required Intervention| O | SEE SECTION H10. |