FDA Adverse Event Malfunction Summary report: N

BD PRECISIONGLIDE¿ NEEDLE

MDR report key: 8095136 · Received November 21, 2018

Report

Report Number
1911916-2018-00662
Event Type
Malfunction
Date Received
November 21, 2018
Date of Event
November 6, 2018
Report Date
December 19, 2018
Manufacturer
BD MEDICAL (BD WEST) MEDICAL SURGICAL
Product Code
FMI
UDI-DI
30382903051282
PMA / PMN Number
K021475
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NJ, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THREE FULL SHELF CARTONS WERE RETURNED IN GOOD CONDITION. TEN RANDOM SAMPLES WERE LEAK TESTED WITH NO ISSUES OR FAILURES NOTED. WE ARE UNABLE TO DETERMINE A ROOT CAUSE BASED ON THE COMPLAINT, THE FACT THAT THERE WERE NO ISSUES DURING ASSEMBLY, AND THE RESULTS OF TESTING PERFORMED ON THE RETURNED SAMPLES WAS ACCEPTABLE. A DEVICE HISTORY RECORD REVIEW WAS COMPLETED. ASSEMBLY BATCH 6090849 HAD 42 VISUAL INSPECTIONS PERFORMED ON 2,100 PARTS WITH ZERO DEFECTS NOTED. SIX LEAK TESTS WERE PERFORMED ON 30 PARTS WITH ZERO FAILURES RECORDED. ASSEMBLY BATCH 6090850 HAD 11 VISUAL INSPECTIONS PERFORMED ON 700 PARTS WITH ZERO DEFECTS NOTED. ONE LEAK TEST WAS PERFORMED ON FIVE PARTS WITH ZERO FAILURES RECORDED. NO QUALITY NOTIFICATIONS WERE WRITTEN FOR THIS BATCH, NOR FOR THE ASSOCIATED ASSEMBLY BATCH. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS.

Description of Event or Problem · 0

IT WAS REPORTED WITH THE USE OF THE BD PRECISIONGLIDE NEEDLE THERE WAS AN ISSUE WITH LEAKAGE. THERE WAS NO REPORT OF INJURY OR MEDICAL INTERVENTION.

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. INITIAL REPORTER: ADDRESS UNAVAILABLE. BD CORPORATE ADDRESS USED. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED WITH THE USE OF THE BD PRECISIONGLIDE¿ NEEDLE THERE WAS AN ISSUE WITH LEAKAGE. THERE WAS NO REPORT OF INJURY OR MEDICAL INTERVENTION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
936853 BD PRECISIONGLIDE¿ NEEDLE HYPODERMIC SINGLE LUMEN NEEDLE FMI BD MEDICAL (BD WEST) MEDICAL SURGICAL 6113649 30382903051282

Patients

Seq Age Sex Outcome Treatment
1 Other