FDA Adverse Event Injury Summary report: N

MERSILENE TAPE UNKNOWN PRODUCT

MDR report key: 8090712 · Received November 20, 2018

Report

Report Number
2210968-2018-77254
Event Type
Injury
Date Received
November 20, 2018
Report Date
November 6, 2018
Manufacturer
ETHICON INC.
Product Code
KDC
PMA / PMN Number
NA
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: GYNECOL SURG. 2012; 9: 219¿222. DOI: 10.1007/S10397-011-0691-7. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: TITLE: "ABDOMINAL CERCLAGE AFTER FAILED TRANSVAGINAL CERVICAL CERCLAGE." AUTHORS: ANWAR MORIA & NOUF ALJAJI & LOUISE MINER & TOGAS TULANDI. CITATION: GYNECOL SURG. 2012; 9: 219¿222. DOI: 10.1007/S10397-011-0691-7. THE AIM OF THIS STUDY WAS TO EVALUATE THE EFFICACY OF ABDOMINAL CERCLAGE BY LAPAROTOMY AND BY LAPAROSCOPY AMONG WOMEN WHO HAD FAILED TRANSVAGINAL CERCLAGE. THE AUTHORS EVALUATED ALL WOMEN WITH CERVICAL INSUFFICIENCY THAT UNDERWENT ABDOMINAL CERCLAGE BETWEEN THE YEARS 2000 AND 2010. OF A TOTAL OF 20 PATIENTS, 12 PATIENTS (AGE: 34.4 ± 1.3; BMI: 24.9 ± 1.6) UNDERWENT ABDOMINAL CERCLAGE BY LAPAROSCOPY AND 8 PATIENTS (AGE: 34.2 ± 0.8; BMI: 23.3 ± 2.4) UNDERWENT ABDOMINAL CERCLAGE BY LAPAROTOMY. DURING THE PROCEDURE IN BOTH TECHNIQUES, THE AUTHORS STARTED BY DISSECTING THE BLADDER PERITONEUM OFF THE CERVIX AND THE AUTHORS USED MERSILENE 5-MM TAPE (ETHICON) FOR THE CERCLAGE. IN THE LAPAROTOMY TECHNIQUE, THE SUTURE WAS INSERTED THROUGH THE AVASCULAR AREA OF THE PARACERVICAL TISSUE MEDIAL TO THE UTERINE VESSELS AND AT THE LEVEL OF THE UTERINE ISTHMUS. IN THE LAPAROSCOPIC GROUP, REPORTED COMPLICATIONS INCLUDED SEVERE OLIGOHYDRAMNIOS (N-1) WHICH REQUIRED LAPAROSCOPIC REMOVAL OF THE CERCLAGE. IN THE LAPAROTOMY GROUP, REPORTED COMPLICATIONS INCLUDED WOUND INFECTION (N-1) AND URINARY TRACT INFECTION (N-1). THE AUTHORS CONCLUDED THAT ABDOMINAL CERCLAGE IN WOMEN WHO HAVE FAILED A TRANSVAGINAL CERVICAL CERCLAGE IS ASSOCIATED WITH A HIGH LIVE BIRTH RATE AND IT COULD BE PERFORMED BY LAPAROSCOPY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
930785 MERSILENE TAPE UNKNOWN PRODUCT INSTRUMENT, SURGICAL, DISPOSABLE KDC ETHICON INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention