Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: GYNECOLOGIC ONCOLOGY. 2011; 121: 565-570. DOI: 10.1016/J.YGYNO.2011.01.032. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: RADICAL ABDOMINAL TRACHELECTOMY FOR CERVICAL MALIGNANCIES: SURGICAL, ONCOLOGICAL AND FERTILITY OUTCOMES ON 62 PATIENTS" AUTHORS: JIN LI, ZITING LI, HUAYING WANG, RONGYU ZANG, YUQI ZHOU, XINGZHU JU, GUIHAO KE, XIAOHUA WU. CITATION: GYNECOLOGIC ONCOLOGY. 2011; 121: 565-570. DOI: 10.1016/J.YGYNO.2011.01.032. THE OBJECTIVES OF THE STUDY WAS TO REPORT THE AUTHORS¿ EXPERIENCE OF RADICAL ABDOMINAL TRACHELECTOMY FOR PATIENTS WITH CERVICAL MALIGNANCIES. THE AUTHORS CONDUCTED A RETROSPECTIVE REVIEW OF A PROSPECTIVELY MAINTAINED DATABASE OF 64 PATIENTS (AGE RANGE: 11 TO 41 YEARS OLD) WHO UNDERWENT FERTILITY-SPARING RADICAL ABDOMINAL TRACHELECTOMY FOR CERVICAL MALIGNANCIES. DURING THE SURGICAL PROCEDURE, ONCE THE SPECIMEN IS REMOVED, A MERSILENE TAPE (ETHICON) IS CIRCUMFERENTIALLY PLACED IN THE SUBSEROSA AROUND THE LOWER UTERINE SEGMENT IN A PURSE-STRING TECHNIQUE AS A PERMANENT CERCLAGE. THE TAPE KNOT IS TIED POSTERIORLY IN THE CUL DE SAC. REPORTED COMPLICATION INCLUDED POST-OPERATIVE CERVICAL STENOSIS (N-5) WHICH REQUIRED NEO-CERVICAL DILATION IN 1 PATIENT, VESICAL DYSFUNCTION (N-1) WHICH REQUIRED RE-INSERTION OF FOLEY CATHETER, DYSPAREUNIA (N-7), PAIN DURING INTERCOURSE (N-6), AND BLEEDING OR SPOTTING AFTER INTERCOURSE (N-7). THE RESULTS SHOWED THAT RADICAL ABDOMINAL TRACHELECTOMY IS FEASIBLE AND CAN BE PERFORMED SAFELY IN WELL-SELECTED PATIENTS WITH CERVICAL MALIGNANCIES WHO WISH TO PRESERVE THEIR FERTILITY. SOCIAL, FAMILIAL, AND PHYSICAL FACTORS CAN LARGELY INFLUENCE THE PATIENTS¿ REPRODUCTIVE OUTCOMES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 904381 | MERSILENE TAPE UNKNOWN PRODUCT | INSTRUMENT, SURGICAL, DISPOSABLE | KDC | ETHICON INC. | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |