FDA Adverse Event Injury Summary report: N

MERSILENE TAPE UNKNOWN PRODUCT

MDR report key: 8028430 · Received November 1, 2018

Report

Report Number
2210968-2018-76871
Event Type
Injury
Date Received
November 1, 2018
Report Date
October 25, 2018
Manufacturer
ETHICON INC.
Product Code
KDC
PMA / PMN Number
NA
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY (2005) 192, 1989¿94; DOI:10.1016/J.AJOG.2005.02.127. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: TITLE: "TRANSVAGINAL PLACEMENT OF CERVICOISTHMIC CERCLAGE: REPORT ON PREGNANCY OUTCOME." AUTHOR(S): MICHAEL KATZ, MD, CAROL ABRAHAMS, MS. CITATION: AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY (2005) 192, 1989¿94; DOI:10.1016/J.AJOG.2005.02.127. THIS RETROSPECTIVE ANALYSIS WAS CONDUCTED TO DESCRIBE THE PREGNANCY OUTCOME FOR A LARGE NUMBER OF PATIENTS WHO HAD A TRANSVAGINAL CERVICOISTHMIC CERCLAGE. OVER A 10-YEAR PERIOD, FROM 1992 TO 2002, 53 PREGNANT WOMEN UNDERWENT SURGERY FOR TRANSVAGINAL PLACEMENT OF A CERCLAGE AT THE LEVEL OF THE CERVICOISTHMIC JUNCTION BETWEEN 12 AND 17 WEEKS OF GESTATION. IN THE PROCEDURE, A 5-MM MERSILENE TAPE WAS THREADED VERY SUPERFICIALLY, FLAT, THROUGH THE TISSUE AT ANTERIOR SURFACE OF THE CERVICOISTHMIC JUNCTION. ONE PATIENT HAD HER SUTURE REMOVED BECAUSE OF DYSPAREUNIA AND VAGINAL DISCHARGE. PROCEDURE-RELATED COMPLICATION INCLUDED INTRAPARTUM CERVICAL TEAR DUE TO INCOMPLETE REMOVAL BEFORE LABOR (N=1); HEMATOMA (<50ML) BETWEEN BLADDER AND CERVIX (N=1) THAT NEEDED TO BE EVACUATED; AND TRANSIENT URINARY RETENTION WITH PELVIC PAIN (N=2). OTHER POSTOPERATIVE COMPLICATIONS INCLUDED ADMISSION FOR REMOVAL OF POSTCERCLAGE HEMATOMA (N=1); LOWER ABDOMINAL PAIN (N=1); AND CHORIOAMNIONITIS (N=2). THE PLACEMENT OF TRANSVAGINAL CERVICOISTHMIC CERCLAGE WAS ASSOCIATED WITH FAVORABLE PREGNANCY OUTCOME AND MAY BE CONSIDERED AS A SUITABLE SAFE ALTERNATIVE TO THE TRANSABDOMINAL CERCLAGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
868840 MERSILENE TAPE UNKNOWN PRODUCT INSTRUMENT, SURGICAL, DISPOSABLE KDC ETHICON INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention