TAXUS EXPRESS2 PACLITAXEL-ELUTING CORONARY STENT SYSTEM
Report
- Report Number
- 6000089-2006-02620
- Event Type
- Injury
- Date Received
- December 21, 2006
- Date of Event
- November 26, 2006
- Report Date
- December 4, 2006
- Manufacturer
- BOSTON SCIENTIFIC CORP.
- Product Code
- NIQ
- PMA / PMN Number
- P030025
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TN, US
- Reporter Occupation
- INVALID DATA
Narratives
H6. A UNIT HAS NOT BEEN RETURNED FOR REVIEW THEREFORE A TECHNICAL ANALYSIS CANNOT BE CARRIED OUT. WITHOUT A RETURNED UNIT, IT IS NOT POSSIBLE TO CONFIRM HOW THE DEVICE MAY HAVE CONTRIBUTED TO THE COMPLAINT INCIDENT. A REVIEW OF THE MANUFACTURING RECORDS FOR THIS PARTICULAR BATCH NAMELY TOP ASSEMBLY BATCH # 6973183 FOUND THAT THE DEVICE MET ITS MATERIAL, ASSEMBLY AND PRODUCT SPECIFICATIONS, AT THE TIME OF RELEASE TO DISTRIBUTION. THE ROOT CAUSE CANNOT BE DETERMINED.
SAME CASE AS MFR# 6000089-2006-02621. IT WAS REPORTED THAT POST INDEX PROCEDURE, THE PATIENT HAD A MYOCARDIAL INFARCTION (MI) AND A TARGET VESSEL REVASCULARIZATION (TVR). THE PATIENT PRESENTED TO THE INDEX PROCEDURE WITH AN ACUTE MI. THE INDEX PROCEDURE TREATED A DE NOVO LESION IN THE DISTAL CIRCUMFLEX (CX). THE LESION WAS 2.4 MM WIDE, 39 MM LONG, AND 100% STENOSED. THERE WAS MILD CALCIFICATION AND MODERATE TORTUOUSITY. THE PHYSICIAN PREDILATED THE LESION PRIOR TO PLACING 2 OVERLAPPING 2.5 X 24 MM TAXUS EXPRESS2 STENTS. RESIDUAL STENOSIS WAS 0%. THE PATIENT RECEIVED A GPIIB/IIIA INHIBITOR AND PLAVIX DURING THE PROCEDURE. THE PATIENT WAS DISCHARGED ONE DAY LATER ON ASPIRIN AND PLAVIX. ON DAY 743, THE PATIENT PRESENTED WITH A NON Q-WAVE MI (NQMI). TO RESOLVE THE EVENT, THE PATIENT UNDERWENT A TVR TO THE DISTAL CX FOR DISTAL EDGE IN-STENT RESTENOSIS. THE EVENTS WERE CONSIDERED RESOLVED THE NEXT DAY AND THE PATIENT WAS DISCHARGED. IN THE OPINION OF THE PHYSICIAN, THERE WAS AN UNKNOWN RELATIONSHIP BETWEEN THE MI AND THE TAXUS STENT, BUT A PROBABLE RELATIONSHIP BETWEEN THE MI AND TARGET VESSEL. IN THE OPINION OF THE PHYSICIAN , THERE WAS A PROBABLE RELATIONSHIP BETWEEN THE TVR AND THE TAXUS STENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | TAXUS EXPRESS2 PACLITAXEL-ELUTING CORONARY STENT SYSTEM | NIQ STENT, CORONARY, DRUG-ELUTING | NIQ | BOSTON SCIENTIFIC CORP. | 2.5 X 24 MM | 6973183 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 53 YR | Hospitalization| L| R |