VIDAS® LYME IGG
Report
- Report Number
- 3002769706-2018-00205
- Event Type
- Malfunction
- Date Received
- October 9, 2018
- Report Date
- March 12, 2019
- Manufacturer
- BIOMERIEUX SA
- Product Code
- LSR
- PMA / PMN Number
- K141133
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- OTHER
Narratives
AN INTERNAL INVESTIGATION WAS PERFORMED FOR A FALSE NEGATIVE RESULT IN ASSOCIATION WITH VIDAS® LYME IGG (1006179040). **COMPLAINT TRENDING ANALYSIS** FOUR COMPLAINTS FOR THE EXTERNAL QUALITY CONTROL ISSUE ON VIDAS LYG BATCH 1006179040/181125-0 LINKED TO THE ACCURUN QUALITY CONTROL SAMPLE. ONE COMPLAINT FOR SENSITIVITY ISSUE ON VIDAS LYG BATCH 1006179040/181125-0 LINKED TO THE PATIENT CLINICAL CONTEXT. THERE IS NEITHER CAPA NOR NON CONFORMITY LINKED TO THIS ISSUE. ** QUALITY CONTROL RECORDS ** THE ANALYSIS OF THE BATCH HISTORY RECORDS OF VIDAS LYG BATCH 1006179040/181125-0 SHOWED NO ANOMALY DURING THE MANUFACTURING, CONTROL AND PACKAGING PROCESSES. ** STUDY OF INTERNAL SAMPLES CONTROL CHARTS** THIS ANALYSIS WAS CARRIED OUT ON SIX INTERNAL POSITIVE CONTROLS THAT INCLUDED THREE SAMPLES WITH HIGH TEST VALUES AND THREE SAMPLES WITH TEST VALUES CLOSE TO THE CUT-OFF FOR VIDAS LYG BATCH 181125-0 COMPARED TO THREE OTHER BATCHES (180802-0, 180929-0 AND 190104-0). ALL THE RESULTS WERE WITHIN ACCEPTABLE RANGES AND VIDAS LYG BATCH 1006179040/181125-0 CONFORMED TO THE PRODUCT SPECIFICATIONS. **TESTS PERFORMED INTERNALLY** BIOMÉRIEUX TESTED SIX INTERNAL SAMPLES FROM THE ACTIVITY PANEL ON VIDAS LYG BATCH 1006179040/181125-0 COMPARED TO TWO OTHER BATCHES MANUFACTURED USING DIFFERENT RAW MATERIAL. ALTHOUGH, VIDAS LYG BATCH 1006179040/181125-0 GIVES SLIGHTLY LOWER TEST VALUES, ALL THE RESULTS ARE WITHIN THE ACCEPTABLE RANGES. THE CUSTOMER'S ACCURUN SAMPLE GAVE POSITIVE RESULTS (BETWEEN 3.19 AND 4.21 TV) WITH THE THREE VIDAS LYG BATCHES (181125-0, 180929-0 AND 190821-0). TESTING REPRODUCED THE LOWER RESULT OBSERVED BY THE CUSTOMER WITH VIDAS LYG BATCH 1006179040/181125-0. THE PATIENT SAMPLE IDENTIFIED 8224623 IS POSITIVE WITH VIDAS LYG BATCHES 180929-0 AND 190821-0 BUT CLOSE TO THE CUT-OFF (0.18 TV) WITH A NEGATIVE INTERPRETATION WHEN TESTING WITH VIDAS LYG BATCH 1006179040/181125-0. TESTING REPRODUCED A NEGATIVE RESULT OBSERVED BY THE CUSTOMER WHEN USING VIDAS LYG BATCH 1006179040/181125-0. **TESTS PERFORMED BY AN EXTERNAL LABORATORY (BIOMNIS)** THE PATIENT SAMPLE 8224623 GAVE A POSITIVE INTERPRETATION WITH PRESENCE OF BANDS ANTI VLSE, ANTI P41 ET ANTI P18. THE ANALYSIS PERFORMED SHOWED THAT VIDAS LYG BATCH 1006179040/181125-0 WAS IN THE TREND OF THE PARAMETER REGARDING ALL THE REQUIRED CRITERIA. ALTHOUGH VIDAS LYG BATCH 1006179040/181125-0 HAD A TREND TO GIVE LOWER RESULTS, ALL THE RESULTS WERE WITHIN ACCEPTABLE RANGES AND WE DID NOT OBSERVED ANY DEGRADATION OF ITS ACTIVITY COMPARED TO ITS RELEASE.
A CUSTOMER IN (B)(6) REPORTED A FALSE NEGATIVE RESULT IN ASSOCIATION WITH VIDAS® LYME IGG (1006179040). THE CUSTOMER REPORTED THAT WHILE COMPARING TEST RESULTS FOR FOUR PATIENT SAMPLES ON TWO DIFFERENT LOTS, THERE WAS A CHANGE OF INTERPRETATION FROM POSITIVE TO NEGATIVE WITH LOT 1006179040, FOR ONE PATIENT SAMPLE. THIS CUSTOMER REPORTED THIS SAMPLE WAS TESTED IN WB: POSITIVE VLSE, P41 POSITIVE AND P18 POSITIVE, AND HAD A LYME M NEGATIVE TEST. THERE IS NO INDICATION OR REPORT FROM THE HOSPITAL OR TREATING PHYSICIAN TO BIOMÉRIEUX THAT THE DISCREPANT RESULT LED TO ANY ADVERSE EVENT RELATED TO THE PATIENT'S STATE OF HEALTH. A BIOMÉRIEUX INTERNAL INVESTIGATION WILL BE INITIATED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 787689 | VIDAS® LYME IGG | VIDAS® LYME IGG | LSR | BIOMERIEUX SA | 1006179040 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |