COMPREHENSIVE MINI HUMERAL STEM
Report
- Report Number
- 0001825034-2018-09202
- Event Type
- Injury
- Date Received
- October 9, 2018
- Date of Event
- March 5, 2017
- Report Date
- March 7, 2019
- Manufacturer
- ZIMMER BIOMET, INC.
- Product Code
- MBF
- PMA / PMN Number
- PK060692
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UT, US
- Reporter Occupation
- 003
Narratives
REPORTED EVENT WAS CONFIRMED BY REVIEW OF MEDICAL RECORDS. OP NOTES DATED FOR THIS REVISION NOTE THAT AS SOON AS THE SURGEON OPENED THROUGH THE DELTOID FASCIA, THEY ENCOUNTERED CLOUDY FLUID, WHICH WAS CULTURED WITH ATTEMPTED REDUCTION OF THE SHOULDER. THE HUMERAL COMPONENT WAS STILL IMPINGING WITH THE INTACT INFERIOR GLENOID, AS WAS EXPECTED FROM THE RADIOGRAPHS. DEVICE HISTORY RECORD (DHR) WAS REVIEWED AND NO DISCREPANCIES RELEVANT TO THE REPORTED EVENT WERE FOUND. A DEFINITE ROOT CAUSE CANNOT BE DETERMINED WITH THE INFORMATION PROVIDED. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
(B)(4). CUSTOMER HAS INDICATED THAT THE PRODUCT WILL NOT BE RETURNED TO ZIMMER BIOMET FOR INVESTIGATION. THE INVESTIGATION IS IN PROCESS. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED. (B)(4). CONCOMITANT MEDICAL PRODUCT: ITEM # 115378, COMP RVS TRAY +10MM CO 44MM, LOT #905990; ITEM # XL-115363, ARCOM XL 44-36 STD HMRL BRNG, LOT # 884300; ITEM # 180550, COMP LK SCR 3.5HEX 4.75X15 ST, LOT # 331030; ITEM # 180554, COMP LK SCR 3.5HEX 4.75X35 ST, LOT # 028240; ITEM # 010000589, COMP RVRS 25MM BSPLT HA+ADPTR, LOT # 017540; ITEM # 115310, COMP RVRS SHLDR GLNSP STD 36MM, LOT # 961680; ITEM # 180550, COMP LK SCR 3.5HEX 4.75X15 ST, LOT # 135680; ITEM # 115396, COMP RVS CNTRL 6.5X30MM ST/RST, LOT # 391730; ITEM # 406669, STN PN THD TIP .125X2.5IN 2PK, LOT # 354400. LEGAL NOTIFICATION. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE ASSOCIATED REPORTS: 0001825034-2018-09193, 0001825034-2018-09194, 0001825034-2018-09195, 0001825034-2018-09196, 0001825034-2018-09197, 0001825034-2018-09198, 0001825034-2018-09199, 0001825034-2018-09200, 0001825034-2018-09201.
IT WAS REPORTED THAT APPROXIMATELY THREE (3) MONTHS POST IMPLANTATION, THE PATIENT UNDERWENT A REVISION TO HAVE THE SHOULDER PROSTHESIS REMOVED WITH IRRIGATION AND DEBRIDEMENT AND THE PLACEMENT OF AN ANTIBIOTIC SPACER. IT IS FURTHER ALLEGED THAT THE PATIENT CONTINUED TO HAVE ANTIBIOTIC TREATMENT FOR INFECTION FROM THE 2ND REVISION, UNTIL PRESENT TIME. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 787247 | COMPREHENSIVE MINI HUMERAL STEM | PROSTHESIS, SHOULDER | MBF | ZIMMER BIOMET, INC. | N/A | 231180 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 84 YR | Hospitalization| R |