TENSION FREE VAGINAL TAPE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2018-76322
- Event Type
- Injury
- Date Received
- October 4, 2018
- Report Date
- September 10, 2018
- Manufacturer
- ETHICON INC.
- Product Code
- OTN
- PMA / PMN Number
- K974098
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCTS USED IN THIS PROCEDURE? CITATION: INTERNATIONAL UROGYNECOLOGY JOURNAL; DOI: HTTPS://DOI.ORG/10.1007/S00192-018-3713-4 (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE "TITLE : ASSESSMENT OF THE LONG-TERM OUTCOME OF TVT PROCEDURE FOR STRESS URINARY INCONTINENCE IN A FEMALE POPULATION: RESULTS AT 17 YEARS¿ FOLLOW-UP" AUTHOR: PANAGIOTIS BAKAS, EMMANOUEL PAPADAKIS, CHARALAMPOS KARACHALIOS, ILIAS LIAPIS, NIKOLAOS PANAGOPOULOS, AGGELOS LIAPIS CITATION: INTERNATIONAL UROGYNECOLOGY JOURNAL; DOI: HTTPS://DOI.ORG/10.1007/S00192-018-3713-4 THE AIM OF THIS PROSPECTIVE STUDY WAS TO ASSESS THE OUTCOME OF THE TENSION-FREE VAGINAL TAPE (TVT) PROCEDURE IN PATIENTS WHO HAD UNDERGONE THE TVT PROCEDURE FOR THE MANAGEMENT OF URODYNAMIC STRESS URINARY INCONTINENCE 17 YEARS AGO. AT THE 17 YEARS FOLLOW-UP, 56 FEMALE PATIENTS WHO HAD UNDERGONE TVT PROCEDURE FOR THE MANAGEMENT OF URODYNAMIC STRESS URINARY INCONTINENCE WERE INCLUDED. THE TVT PROCEDURE WAS CARRIED OUT WITH TVT (GYNECARE ¿ ETHICON). AT THE FOLLOW-UP PERIOD, TWO PATIENTS REPORTED RECURRENT URINARY TRACT INFECTION WHICH WERE TREATED WITH ANTIBIOTIC THERAPY±PROPHYLALXIS, AND ONE PATIENT HAD TVT EROSION FULLY DEVELOPED AT 29 MONTHS POST-PROCEDURE WHICH WAS TREATED BY CUTTING OF THE PROJECTING EDGES OF TAPE INTO THE VAGINA AND LOCAL ESTROGENS. SUBJECTIVE FAILURE WAS REPORTED BY 7 PATIENTS. THE INCREASE IN THE INCIDENCE OF THE DE NOVO DEVELOPMENT OF OAB SYMPTOMS COULD BE ATTRIBUTED TO THE INCREASED PATIENT¿S AGE. THE POSSIBLE EXPLANATION OF THE PATIENTS WHO REPORTED DIFFICULTY EMPTYING THE BLADDER COULD BE LOCAL CHANGES IN SENSATION SECONDARY TO MENOPAUSE. THE TVT PROCEDURE FOR THE MANAGEMENT OF STRESS URINARY INCONTINENCE IN WOMEN MAINTAINS ITS EFFICACY IN THE LONG TERM, HAVING AN OBJECTIVE CURE RATE OF 83.9% AND A SUBJECTIVE CURE RATE OF 78.6% AT 17 YEARS¿ FOLLOW-UP, WITH A VERY LOW COMPLICATIONS RATE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 776215 | TENSION FREE VAGINAL TAPE UNKNOWN PRODUCT | MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGICAL | OTN | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |