VITROS CHEMISTRY PRODUCTS VALP REAGENT
Report
- Report Number
- 1319808-2018-00028
- Event Type
- Malfunction
- Date Received
- October 2, 2018
- Date of Event
- September 5, 2018
- Report Date
- October 2, 2018
- Manufacturer
- ORTHO-CLINICAL DIAGNOSTICS
- Product Code
- LEG
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- RP
- Reporter Occupation
- OTHER
Narratives
THE INVESTIGATION CONCLUDED THAT HIGHER AND LOWER THAN EXPECTED RESULTS WERE OBTAINED FROM THREE DIFFERENT LEVELS OF VITROS TDM PV QUALITY CONTROL FLUIDS USING VITROS VALP REAGENT, ON A VITROS 5,1 FS CHEMISTRY SYSTEM. THE ASSIGNABLE CAUSE OF THE HIGHER THAN EXPECTED VITROS VALP RESULTS OBTAINED USING VITROS TDM PV FLUIDS WAS DETERMINED TO BE CALIBRATION RELATED. THE RESPONSES AND PARAMETERS OF THE AFFECTED CALIBRATION APPEARED ATYPICAL TO EXPECTED RESPONSES AND PARAMETERS. RECALIBRATING WITH AN ALTERNATE SET OF CALIBRATORS FROM THE SAME LOT HAD RESOLVED THE ISSUE. THE DEFINITIVE ASSIGNABLE CAUSE OF THE LOWER THAN EXPECTED VITROS TDM PV FLUID RESULTS WAS UNKNOWN, HOWEVER, PRE-ANALYTICAL SAMPLE MIX UP AND IMPROPER FLUID HANDLING PROTOCOL COULD NOT BE RULED OUT AS CONTRIBUTING FACTORS TO THE EVENT. WITHIN-RUN PRECISION TESTING USED TO ASSESS INSTRUMENT PERFORMANCE WAS NOT PERFORMED AND THEREFORE AN INSTRUMENT ISSUE CANNOT BE RULED OUT AS A POTENTIAL CONTRIBUTOR. ACCEPTABLE RESULTS WERE OBTAINED FROM THE SAME REAGENT PACKS THAT INITIALLY GENERATED LOWER THAN EXPECTED RESULTS. ONGOING TRACKING AND TRENDING OF COMPLAINT DATA HAS NOT IDENTIFIED ANY SIGNALS TO SUGGEST THERE IS A SYSTEMIC QUALITY ISSUE WITH VITROS VALP REAGENT LOT 2511-25-6393. THEREFORE, A VITROS VALP REAGENT RELATED ISSUE DID NOT LIKELY CONTRIBUTE TO THE EVENT.
A CUSTOMER OBTAINED HIGHER AND LOWER THAN EXPECTED RESULTS FROM THREE DIFFERENT LEVELS OF VITROS TDM PERFORMANCE VERIFIER (PV) QUALITY CONTROL FLUIDS USING VITROS VALPROIC ACID (VALP) REAGENT ON A VITROS 5,1 FS CHEMISTRY SYSTEM. HIGHER THAN EXPECTED RESULTS: VITROS TDM PV I Q5894 RESULTS OF 277.5 AND 351.7 UMOL/L VS. THE EXPECTED RESULT OF 170 UMOL/L. VITROS TDM PV II N5702 RESULTS OF 602.2 AND 722.5 UMOL/L VS. THE EXPECTED RESULT OF 477.5 UMOL/L. VITROS TDM PV III P5703 RESULTS OF 1039.5 UMOL/L VS. THE EXPECTED RESULT OF 835 UMOL/L. LOWER THAN EXPECTED RESULTS: VITROS TDM PV I Q5894 RESULTS OF LESS THAN 69.3 (X5) UMOL/L VS. THE EXPECTED RESULT OF 170 UMOL/L. VITROS TDM PV II N5702 RESULTS OF LESS THAN 69.3 (X5) AND 378.3 UMOL/L VS. THE EXPECTED RESULT OF 477.5 UMOL/L. VITROS TDM PV III P5703 RESULTS OF LESS THAN 69.3, LESS THAN 69.3, 81.9, 81.9, AND 137.6 UMOL/L VS. THE EXPECTED RESULT OF 835 UMOL/L. BIASED RESULTS OF THE DIRECTION AND MAGNITUDE OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THE ISSUE WERE TO OCCUR UNDETECTED ON PATIENT SAMPLES. THE UNEXPECTED VITROS VALP RESULTS WERE GENERATED FROM NON-PATIENT FLUIDS, HOWEVER THE INVESTIGATION CANNOT CONCLUDE THAT PATIENT SAMPLE RESULTS WERE NOT AFFECTED AND WOULD NOT BE AFFECTED IF THE EVENT WERE TO RECUR UNDETECTED. THERE WAS NO ALLEGATION OF ACTUAL PATIENT HARM AS A RESULT OF THIS EVENT. THIS REPORT IS NUMBER TWO OF THREE MDR¿S FOR THIS EVENT. THREE 3500A FORMS ARE BEING SUBMITTED FOR THIS EVENT AS THREE DEVICES WERE INVOLVED. THIS REPORT CORRESPONDS TO ORTHO CLINICAL DIAGNOSTICS INC (ORTHO). COMPLAINT NUMBERS (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 767508 | VITROS CHEMISTRY PRODUCTS VALP REAGENT | IN-VITRO DIAGNOSTIC | LEG | ORTHO-CLINICAL DIAGNOSTICS | 2511-25-6393 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |