FDA Adverse Event Injury Summary report: N

PROLENE POLYPROPYLENE MESH UNKNOWN PRODUCT

MDR report key: 7927482 · Received October 2, 2018

Report

Report Number
2210968-2018-76223
Event Type
Injury
Date Received
October 2, 2018
Report Date
September 6, 2018
Manufacturer
ETHICON INC.
Product Code
FTL
PMA / PMN Number
K962530
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
EG
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCT INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT INVOLVED? CITATION: HERNIA. 2015; 19: 141¿146. DOI: 10.1007/S10029-013-1143-2. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE "TITLE: COMPARISON BETWEEN THE SHORT-TERM RESULTS OF ONLAY AND SUBLAY MESH PLACEMENT IN THE MANAGEMENT OF UNCOMPLICATED PARA-UMBILICAL HERNIA: A PROSPECTIVE RANDOMIZED STUDY" AUTHORS: S. S. BESSA, A. M. EL-GENDI, A.-H. A. GHAZAL, T. A. AL-FAYOUMI CITATION: HERNIA. 2015; 19: 141¿146. DOI: 10.1007/S10029-013-1143-2. THE AIM OF THIS STUDY WAS TO COMPARE BETWEEN THE SHORT-TERM RESULTS OF ONLAY AND SUBLAY MESH PLACEMENT IN THE PROSTHETIC REPAIR OF UNCOMPLICATED PARA-UMBILICAL HERNIA (PUH). A TOTAL OF 80 PATIENTS WITH A DEFECT SIZE RANGING FROM 4 TO 10 CM WERE PROSPECTIVELY RANDOMIZED TO EITHER THE ONLAY GROUP (40 PATIENTS; 6 MALE AND 34 FEMALE PATIENTS; AGE RANGE: 26 TO 57 YEARS OLD; BMI: 25 TO 37) OR THE SUBLAY GROUP (40 PATIENTS; 5 MALE AND 35 FEMALE PATIENTS; AGE RANGE: 24 TO 59 YEARS OLD; BMI: 25 TO 36). THE OPERATIVE TIME, POSTOPERATIVE COMPLICATIONS, AND SHORT TERM RECURRENCE WERE REPORTED. IN THE SUBLAY GROUP, THE RETROMUSCULAR SPACE WAS DEVELOPED TO ALLOW THE INSERTION OF A 15 ×15 CM MONOFILAMENT PROLENE POLYPROPYLENE MESH (ETHICON) IN ALL PATIENTS AS FOLLOWS. THE PERITONEAL CAVITY WAS THEN CLOSED BY SUTURING THE PERITONEUM-POSTERIOR RECTUS SHEATH LAYER OF BOTH SIDES. THIRD, PERIPHERAL FIXATION OF THE MESH WAS PERFORMED AS FOLLOWS. A PROLENE 0 SUTURE (ETHICON) WAS PLACED THROUGH THE INFOLDED EDGE OF THE MESH. IN THE ONLAY GROUP, THE MARGINS OF THE DEFECT WERE IDENTIFIED AND SECONDARY DEFECTS WERE SEARCHED FOR CAREFULLY AND CONNECTED WITH THE MAIN DEFECT. NEXT, THE DEFECT WAS VERTICALLY CLOSED BY SIMPLE INTERRUPTED NON-ABSORBABLE PROLENE 1-0 SUTURES (ETHICON). NEXT, SKIN AND SUBCUTANEOUS FLAPS WERE ELEVATED TO FIT A 15 × 15 CM MONOFILAMENT PROLENE POLYPROPYLENE MESH (ETHICON). THE MESH WAS FIXED TO THE ABDOMINAL WALL MUSCLES AS AN ONLAY PATCH USING INTERRUPTED NON-ABSORBABLE PROLENE 2-0 SUTURES (ETHICON). IN THE SUBLAY GROUP, REPORTED COMPLICATION INCLUDED SUPERFICIAL WOUND INFECTION (N-1) WHICH REQUIRED ANTIBIOTICS GUIDED BY CULTURE AND SENSITIVITY STUDIES AND RECURRENCE OF HERNIA (N-2). IN THE ONLAY GROUP, REPORTED COMPLICATION INCLUDED SEROMA (N-2) WHICH REQUIRED RE-INSERTION OF THE CATHETER TUBE DRAIN UNDER LOCAL ANESTHESIA FOR AN EXTRA WEEK AND RECURRENCE OF HERNIA (N-2). THE MAIN FINDINGS OF THE PRESENT STUDY SUGGEST THAT BOTH MESH POSITIONS WERE ASSOCIATED WITH COMPARABLE COMPLICATION AND RECURRENCE RATES AND THAT BOTH TECHNIQUES MAY BE APPLIED EFFECTIVELY IN THE MANAGEMENT OF UNCOMPLICATED PUH. BOTH THE SUBLAY AND ONLAY MESH PLACEMENT TECHNIQUES ARE SAFE, EFFICIENT, AND ARE ASSOCIATED WITH COMPARABLE COMPLICATION AND RECURRENCE RATES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
768786 PROLENE POLYPROPYLENE MESH UNKNOWN PRODUCT MESH, SURGICAL, POLYMERIC FTL ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention