BARD® TOUCHLESS® PLUS UNISEX PRE-LUBRICATED VINYL URETHRAL CATHETER KIT
Report
- Report Number
- 1018233-2018-04485
- Event Type
- Injury
- Date Received
- October 1, 2018
- Report Date
- November 11, 2018
- Manufacturer
- C.R. BARD, INC. (COVINGTON) -1018233
- Product Code
- FCM
- UDI-DI
- 00801741030550
- PMA / PMN Number
- K910653
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- 003
Narratives
THE DEVICE WAS NOT RETURNED FOR EVALUATION. THE DEVICE HISTORY RECORD WAS REVIEWED AND FOUND NOTHING THAT COULD HAVE CAUSED OR CONTRIBUTED TO THE REPORTED EVENT. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: "BARD® TOUCHLESS¿ PLUS UNISEX PRE-LUBRICATED URETHRAL CATHETER KIT, UNITS, SINGLE USE. CONTENTS: VINYL URETHRAL CATHETER, 1100CC COLLECTION BAG, 3 POVIDONE-IODINE SWABS, 2 AMBIDEXTROUS GLOVES, WATERPROOF UNDERPAD, STERILIZED USING ETHYLENE OXIDE, DO NOT RESTERILIZE. DO NOT USE IF PACKAGE IS DAMAGED. CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. HANDLE AND DISPOSE OF IN ACCORDANCE WITH ACCEPTED MEDICAL PRACTICE AND WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. (B)(4). INSTRUCTIONS FOR USE: PREPARING FOR CATHETERIZATION: 1. OPEN KIT AND REMOVE CONTENTS. 2. THE GLOVES ARE NOT NECESSARY TO MAINTAIN ASEPTIC CONDITIONS DURING THE PROCEDURE. THE GLOVES ARE FOR THE OPERATOR'S PROTECTION. MALE/FEMALE CATHETERIZATION: 1. REMOVE CAP FROM INSERTION TIP WHILE SQUEEZING TABS. SAVE CAP FOR CLOSING THE BAG. 2. SLIDE THE CATHETER HALFWAY INTO THE INSERTION TIP. 3. MALE - PREPARE THE MALE URETHRAL MEATUS AND THE SURROUNDING AREA WITH POVIDONE-IODINE SWABS PROVIDED. FEMALE - PREPARE THE FEMALE URETHRAL MEATUS BY HOLDING THE OUTER LABIA APART AND PREP THE URETHRAL MEATUS AND SURROUNDING AREA WITH POVIDONE IODINE SWABS PROVIDED. 4. MALE - HOLDING THE PENIS, ADVANCE THE INSERTION TIP INTO THE URETHRA NO FURTHER THAN THE FLANGE BASE. FEMALE - SPREAD THE INNER LABIA, ADVANCE THE INSERTION TIP INTO THE URETHRA NO FURTHER THAN THE FLANGE BASE. RELEASE THE INNER LABIA. 5. PLACE YOUR NONDOMINANT HAND ON THE FINGER CONTROL GUIDE TO STABILIZE CATHETER IN URETHRA. WITH YOUR DOMINANT HAND, GRASP CATHETER THROUGH BAG APPROXIMATELY 1" BELOW THE FINGER CONTROL GUIDE AND PUSH CATHETER INTO URETHRA. THE CATHETER SHOULD BE INTRODUCED BY SHORT, REPETITIVE PUSHING MOTIONS. REPEAT MOTIONS UNTIL CATHETER REACHES BLADDER AND URINE STARTS TO FLOW. 6. ALLOW URINE TO FLOW FREELY, MAKING CERTAIN THE CATHETER GUIDE IS ELEVATED AT LEAST 4" ABOVE LOWER PORTION OF THE BAG. ALLOW FLOW UNTIL BLADDER IS EMPTY OR UNTIL BAG IS FILLED. PRECAUTION: IT IS RECOMMENDED THAT THE COLLECTION BAG BE HELD. THE CATHETER COULD POSSIBLY SEPARATE FROM THE COLLECTION BAG WHEN URINE INCREASES WEIGHT OF THE BAG. 7. WITHDRAW THE CATHETER FROM THE URETHRA. REMOVE THE REMAINING PORTION OF THE CATHETER FROM THE COLLECTION BAG BY PULLING IT THROUGH THE INSERTION TIP. NOTE: THE CATHETER IS DESIGNED TO PASS THROUGH THE INSERTION TIP. 8. THE FILLED COLLECTION BAG MAY BE CLOSED BY REPLACING THE CAP OVER THE INSERTION TIP. MAKE SURE THE CAP SNAPS ON SECURELY. SPECIMEN COLLECTION: TO COLLECT A SPECIMEN, OBTAIN A SAMPLE CUP/TUBE AND ALCOHOL WIPE. REMOVE GUIDE TIP BY PULLING TAB(S) UPWARD FROM BAG. WIPE PORT WITH ALCOHOL. POUR SPECIMEN THROUGH PORT AT TOP OF BAG INTO CUP/TUBE. DRAINING BAG: REMOVE INSERTION TIP BY PULLING TAB(S) UPWARD FROM BAG. DRAIN URINE THROUGH PORT AT TOP OF BAG. MANUFACTURED IN MEXICO. BARD AND TOUCHLESS ARE TRADEMARKS AND/OR REGISTERED TRADEMARKS OF C. R. BARD, INC."
IT WAS REPORTED THAT THE PATIENT EXPERIENCED A URINARY TRACT INFECTION FOLLOWING THE USE OF THE CATHETER. THE KIT WAS MANUFACTURED WITHOUT THE POVIDONE-IODINE PRE-SATURATED SWABSTICKS DUE TO A MARKET WIDE SHORTAGE. THE PATIENT ALLEGEDLY FELT THAT THE LACK OF POVIDONE-IODINE PRE-SATURATED SWABSTICKS WITHIN THE KIT CONTRIBUTED TO THE URINARY TRACT INFECTION. THE PATIENT REPORTEDLY WENT TO THE ER AND WAS GIVEN IV ANTIBIOTICS TO TREAT THE URINARY TRACT INFECTION.
THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. THE INFORMATION PROVIDED BY BARD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BARD. THE DEVICE WAS NOT RETURNED.
IT WAS REPORTED THAT THE PATIENT EXPERIENCED A URINARY TRACT INFECTION FOLLOWING THE USE OF THE CATHETER. THE KIT WAS MANUFACTURED WITHOUT THE POVIDONE-IODINE PRE-SATURATED SWABSTICKS DUE TO A MARKET WIDE SHORTAGE. THE PATIENT ALLEGEDLY FELT THAT THE LACK OF POVIDONE-IODINE PRE-SATURATED SWABSTICKS WITHIN THE KIT CONTRIBUTED TO THE URINARY TRACT INFECTION. THE PATIENT REPORTEDLY WENT TO THE ER AND WAS GIVEN IV ANTIBIOTICS TO TREAT THE URINARY TRACT INFECTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 762490 | BARD® TOUCHLESS® PLUS UNISEX PRE-LUBRICATED VINYL URETHRAL CATHETER KIT | TOUCHLESS PLUS | FCM | C.R. BARD, INC. (COVINGTON) -1018233 | NGBZ2692 | 00801741030550 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |