ALPHASTAR MOBILE OPERATING TABLE
Report
- Report Number
- 8010652-2018-00023
- Event Type
- Malfunction
- Date Received
- September 26, 2018
- Date of Event
- August 28, 2018
- Report Date
- September 25, 2018
- Manufacturer
- HOLGER ULLRICH
- Product Code
- FQO
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- BR
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF THE LEGAL MANUFACTURER OF THE DEVICE MAQUET GMBH, KEHLER STRASSE 31, RASTATT, GERMANY 76437. EXEMPTION # E2018004. GETINGE USA SALES, LLC, 45 BARBOUR POND DRIVE, WAYNE, NJ 07470. CONTACT PERSON: (B)(4). PICTURES FROM THE TABLE IN QUESTION WERE PROVIDED BY THE CUSTOMER. THE PICTURES SHOW A BREAK AT THE JOINTS OF THE LEG PLATE PART OF THE TABLE TOP. FURTHER THE CUSTOMER INFORMED US THAT THE WHOLE PATIENT WAS POSITIONED ON THE LEG PLATE PART OF THE TABLE TOP TO PERFORM A UROLOGY SURGERY. IN THE INSTRUCTIONS FOR USE OF THE PRODUCT IT IS STATED THAT FOR THESE KINDS OF SURGERIES THE LEG PLATE HAS TO BE BEND DOWN AND THE PATIENT HAS TO BE POSITIONED ON THE BACK PLATE. THIS WAY THE CENTER OF GRAVITY OF THE PATIENT IS LOCATED ABOVE THE COLUMN OF THE OPERATING TABLE AND NO HIGH FORCES ARE EXERTED TO THE JOINTS OF THE TABLE TOP. WE ASSUME THAT THE TABLE TOP / THE LEG PLATE PART WAS PRE-DAMAGED DUE TO COLLISION(S) IN THE COURSE OF TIME. SUCH COLLISION(S) MAY BUT DO NOT NECESSARILY LEAD TO AN IMMEDIATE MALFUNCTION OF THE LEG PLATE. THE LEG PLATE MAY ONLY BE PRE-DAMAGED AND BROKE AT LEAST AT THIS CASE. IN THE INSTRUCTIONS FOR USE IT IS STATED THAT THE USER MUST CONSTANTLY OBSERVE THE OPERATING TABLE AND THE ACCESSORIES DURING ADJUSTMENT IN ORDER TO AVOID COLLISIONS. THE TABLE IN QUESTION WAS MANUFACTURED IN 2000 AND HAS BEEN IN CLINICAL USE FOR OVER 17 YEARS. GETINGE - MAQUET GMBH PROVIDES PRODUCT FAILURE INVESTIGATION, ANALYSIS AND RESOLUTION FOR THE DEVICE DESCRIBED IN THIS REPORT.
WE WERE INFORMED BY THE CLINIC THAT AT THE BEGINNING OF A PROCEDURE THE LEG PLATE OF THE OPERATING TABLE BROKE AND THE PATIENT FELL FROM THE TABLE. NO INJURY HAS BEEN REPORTED TO GETINGE - MAQUET. THE PATIENT WAS TRANSFERRED TO ANOTHER TABLE AND THE PROCEDURE WAS PERFORMED WITHOUT ANY COMPLICATION. (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 752087 | ALPHASTAR MOBILE OPERATING TABLE | TABLE, OPERATING-ROOM, AC-POWERED | FQO | HOLGER ULLRICH | 113201A0 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 33 YR | Other |