FDA Adverse Event Injury Summary report: N

ROD, FIXATION, INTRAMEDULLARY

MDR report key: 7902032 · Received September 24, 2018

Report

Report Number
2939274-2018-53909
Event Type
Injury
Date Received
September 24, 2018
Date of Event
January 20, 2007
Report Date
August 28, 2018
Manufacturer
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
Product Code
HSB
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DATE OF EVENT: THERE ARE MULTIPLE UNKNOWN DATES OF EVENT. THIS REPORT IS FOR AN UNKNOWN SCREW/UNKNOWN LOT. PART AND LOT NUMBERS ARE UNKNOWN; UDI NUMBER IS UNKNOWN. IMPLANTED DATES: THERE ARE MULTIPLE UNKNOWN DATES OF IMPLANTATION BETWEEN (B)(6) 1999 AND (B)(6) 2004. EXPLANTED DATES: IT IS UNKNOWN IF OR WHEN DEVICES WERE EXPLANTED. COMPLAINANT PART IS NOT EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION. WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RECEIVED. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. (B)(4).

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER THE REVIEW OF THE FOLLOWING JOURNAL ARTICLE: MORSHED S, ET AL (2007). RETENTION OF FLEXIBLE INTRAMEDULLARY NAILS FOLLOWING TREATMENT OF PEDIATRIC FEMUR FRACTURES. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY. VOLUME 127. ISSUE 7. PAGES 509-514. (USA). THE PURPOSE OF THIS STUDY IS TO DESCRIBE THE NATURAL HISTORY OF TREATMENT OF PEDIATRIC FEMUR FRACTURES WITH RETENTION OF FLEXIBLE INTRAMEDULLARY NAILS AS MEASURED BY NEED FOR FURTHER SURGERY AND RESIDUAL SYMPTOMS. BETWEEN OCTOBER 1999 AND MARCH 2004, 24 SCHOOL AGE CHILDREN (25 FEMURS) WHO UNDERWENT INTERNAL FIXATION OF A DIAPHYSEAL FEMUR FRACTURE WITH FLEXIBLE TITANIUM NAILS WITHOUT PLANNED IMPLANT REMOVAL, WERE INCLUDED IN THE STUDY. THERE WERE 4 GIRLS AND 20 BOYS WITH A MEAN AGE OF 9.2 YEARS (RANGE, 6.5-13 YEARS). PATIENTS WERE IMPLANTED WITH 2 TO 3 UNKNOWN SYNTHES TITANIUM ELASTIC NAIL IN A RETROGRADE FASHION THROUGH THE DISTAL PART OF THE FEMUR DEPENDING ON FRACTURE PATTERN AND STABILITY. FOLLOW-UP WITH RADIOGRAPHIC EXAMINATION AND ASSESSMENT OF ALIGNMENT, CALLUS FORMATION, AND THE STATUS OF THE IMPLANTS WERE DONE UNTIL FRACTURES HAD HEALED AND PATIENTS HAD RETURNED TO FULL ACTIVITY. PATIENTS AND CAREGIVERS WERE ASSESSED USING QUESTIONNAIRES REGARDING THE PRESENCE OR ABSENCE OF PAIN (SCALE FROM 1 TO 10), INCIDENCE OF FURTHER COMPLICATIONS OR REQUIREMENT OF A SECOND SURGERY TO REMOVE THE NAILS AVERAGE FOLLOW-UP WAS 3.6 YEARS (RANGE 1.4¿4.8 YEARS). COMPLICATIONS WERE REPORTED AS FOLLOWS: 4 PATIENTS WITH RODS IN PLACE REPORTED THIGH DISCOMFORT. A 10.3 YEAR OLD MALE CHILD, WITH RIGHT SIDE TRANSVERSE MIDDLE THIRD FEMORAL FRACTURE, HAD IMPLANT REMOVAL AT 1.6 YEARS POST-OP DUE TO PAIN AND IRRITATION. LOCAL IRRITATION IMPROVED FOLLOWING NAIL REMOVAL. A 10.3 YEAR OLD MALE CHILD, WITH LEFT SIDE TRANSVERSE DISTAL THIRD FEMORAL FRACTURE, HAD IMPLANT REMOVAL AT 1.6 YEARS POST-OP DUE TO PAIN AND IRRITATION. LOCAL IRRITATION IMPROVED FOLLOWING NAIL REMOVAL. A 6.6 YEAR OLD MALE CHILD, WITH RIGHT SIDE OBLIQUE MIDDLE THIRD FEMORAL FRACTURE, HAD IMPLANT REMOVAL AT 0.6 YEARS POST-OP DUE TO PAIN AND IRRITATION. LOCAL IRRITATION IMPROVED FOLLOWING NAIL REMOVAL. A 9.1 YEAR OLD FEMALE CHILD, WITH LEFT SIDE OBLIQUE MIDDLE THIRD FEMORAL FRACTURE, HAD IMPLANT REMOVAL AT 0.7 YEARS POST-OP DUE TO PAIN AND IRRITATION. LOCAL IRRITATION IMPROVED FOLLOWING NAIL REMOVAL. A 13 YEAR OLD MALE CHILD, WITH RIGHT SIDE SPIRAL PROXIMAL THIRD FEMORAL FRACTURE, HAD IMPLANT REMOVAL AT 2.8 YEARS POST-OP DUE TO PAIN AND IRRITATION. LOCAL IRRITATION IMPROVED FOLLOWING NAIL REMOVAL. A 10.4 YEAR OLD MALE CHILD, WITH RIGHT SIDE OBLIQUE MIDDLE THIRD FEMORAL FRACTURE, HAD IMPLANT REMOVAL AT 1 YEAR POST-OP DUE TO PAIN AND IRRITATION. LOCAL IRRITATION IMPROVED FOLLOWING NAIL REMOVAL. THIS REPORT IS FOR ONE (1) DEVICE- AN UNKNOWN SYNTHES TITANIUM ELASTIC NAIL. THIS IS REPORT 1 OF 7 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
743064 ROD, FIXATION, INTRAMEDULLARY HSB WRIGHTS LANE SYNTHES USA PRODUCTS LLC

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention