FDA Adverse Event Injury Summary report: N

PROTEGE RX CAROTID STENT SYSTEM

MDR report key: 7901359 · Received September 24, 2018

Report

Report Number
2183870-2018-00448
Event Type
Injury
Date Received
September 24, 2018
Date of Event
March 29, 2017
Report Date
September 24, 2018
Manufacturer
COVIDIEN
Product Code
NIM
PMA / PMN Number
P060001
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

PREDICTION OF CEREBRAL HYPERPERFUSION AFTER CAROTID ARTERY STENTING BY CEREBRAL ANGIOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY WITHOUT ACETAZOLAMIDE CHALLENGE. TSUYOSHI OHTA, MD, PHD; ICHIRO NAKAHARA, MD, PHD; SHOJIMATSUMOTO, MD, PHD; RYOTA ISHIBASHI, MD; HARUKAMIYATA, MD; HIDEHISA NISHI, MD; S ADAYOSHIWATANABE, MD; IZUMI NAGATA,MD, PHD. NEUROSURGERY 81: 512¿519, 2017. HTTPS://DOI.ORG/10.1093/NEUROS/NYX041. AVERAGE AGE. MAJORITY GENDER. ESTIMATE BASED ON ARTICLE PUBLICATION DATE. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

THE AUTHORS PERFORMED A RETROSPECTIVE STUDY OF PATIENTS UNDERGOING AN INITIAL CAROTID ARTERY STENTING (CAS) PROCEDURE FOR CAROTID ARTERY STENOSIS. IT WAS THEIR INTENT TO DEMONSTRATE THE UTILITY OF SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY (SPECT) IN CORRELATION WITH THE PATIENT¿S CEREBRAL ANGIOGRAM TO ASSESS THE RISK OF CEREBRAL HYPERPERFUSION SYNDROME. PATIENTS UNDERWENT STRICT REGULATION OF EACH DISEASE PRIOR TO TREATMENT. PATIENTS WERE PRESCRIBED 100 MG ASPIRIN AND 75 MG CLOPIDOGREL AT LEAST 3 DAYS PRIOR TO THE START OF TREATMENT. ALL TREATMENTS WERE PERFORMED UNDER SYSTEMIC HEPARINIZATION, WHICH WAS TITRATED TO AN ACTIVATED CLOTTING TIME OF 250 TO 350 S ONLY DURING THE PROCEDURE. UNDER DISTAL PROTECTION WITH A BALLOON OR FILTER WIRE, THE STENOSIS WAS PREDILATED WITH A 3.0 TO 3.5 MM BALLOON CATHETER AND A SELF-EXPANDING STENT DEPLOYED. THIRTY SEVEN CASES RECEIVED OPEN-CELL STENTS (OUT OF A TOTAL OF 100 CASES), WHICH CONSISTED OF 11 PROTEGE STENTS. THEIR FINDINGS WERE THAT PREOPERATIVE ASYMMETRY INDEX (AI) ON THE SPECT AND LEPTOMENINGEAL ANASTOMOSIS PREDICTED CEREBRAL HYPERPERFUSION PHENOMENON (CHP); AND CHP OCCURRED IN ALL CASE OF CEREBRAL HYPERPERFUSION SYNDROME. THE AUTHORS REPORTED 9 PATIENTS OF THE INCLUDED 100 PATIENTS WHO DEVELOPED CHP, AND 5 OF THEM HAD CEREBRAL HYPERPERFUSION SYNDROME. AS THE AUTHORS OF THE PRESENT ARTICLE POINT OUT, THIS MAY BE PREVENTED BY A MORE AGGRESSIVE REDUCTION IN BLOOD PRESSURE AT THE TIME OF REVASCULARIZATION. ANECDOTALLY, IT WOULD APPEAR MORE CASES OF CHP ARE ENCOUNTERED IN PATIENTS IN WHICH SIGNIFICANT DOSES OF ANTIHYPERTENSIVE AGENTS ARE REQUIRED TO ACHIEVE AN ACCEPTABLE BLOOD PRESSURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
744059 PROTEGE RX CAROTID STENT SYSTEM STENT, CAROTID NIM COVIDIEN

Patients

Seq Age Sex Outcome Treatment
1 73 YR Required Intervention