SERVO-U
Report
- Report Number
- 8010042-2018-00496
- Event Type
- Malfunction
- Date Received
- September 21, 2018
- Report Date
- November 9, 2018
- Manufacturer
- MAQUET CRITICAL CARE AB
- Product Code
- CBK
- PMA / PMN Number
- K151814
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- VA
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
NO VENTILATOR LOGS WERE PROVIDED AND NO PARTS WERE RETURNED FOR INVESTIGATION. NO FURTHER INFORMATION WAS PROVIDED BY THE USER FACILITY REGARDING THE USE OF HIGH FREQUENCY JET VENTILATOR (HFJV) IN TANDEM WITH THE VENTILATOR. THE REPORTED TANDEM USE OF A HFJV IMPLIES THAT THE HFJV IS CONNECTED TO AN ET TUBE ADAPTER AND IT INDUCES A ¿JET¿ OF GAS OUT OF THE ADAPTER INTO THE AIRWAY. THE MEASURED INSPIRATORY VALUES WOULD BE AS PER THE SET PARAMETER VALUES BUT THE MEASURED EXPIRATORY VALUES WOULD INCLUDE THE VALUES OF THE HFJV AND THEREFORE, THE MEASURED EXPIRATORY VALUES WOULD NOT REFLECT THE PARAMETER SETTINGS AND WILL LEAD TO GENERATION OF APPROPRIATE ALARMS, FOR EXAMPLE FOR HIGH O2 CONCENTRATION. THE USE OF A HFJV IN TANDEM WITH THE VENTILATOR HAS NOT BEEN TESTED, APPROVED, OR RECOMMENDED FOR USE WITH THIS VENTILATOR SYSTEM. THEREFORE THE CONSEQUENCES OF ITS USE WITH OUR VENTILATOR ARE UNKNOWN. AS NO LOG FILES WERE PROVIDED AND NO PARTS WERE REPLACED AND RETURNED FOR OUR INVESTIGATION, IT HAS NOT BEEN POSSIBLE TO DETERMINE THE ROOT CAUSE OF THE REPORTED EVENT BUT THE USE OF HFJV IN TANDEM WITH THE VENTILATOR IS THE MOST LIKELY CONTRIBUTING FACTOR.GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF MAQUET CRITICAL CARE AB (MANUFACTURER). REF. EXEMPTION #: E2018003. GETINGE USA SALES, LLC 45 BARBOUR POND DRIVE WAYNE, NJ 07470. CONTACT PERSON: (B)(4).
GETINGE USA SALES, LLC (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF MAQUET CRITICAL CARE AB (MANUFACTURER). REF. EXEMPTION #: E2018003 GETINGE USA SALES, LLC 45 BARBOUR POND DRIVE WAYNE, NJ 07470 CONTACT PERSON: (B)(4).
IMPORTER REF. #: (B)(4). MANUFACTURER REF. #: (B)(4).
IT WAS REPORTED THAT DURING VENTILATION, ALARMS FOR HIGH O2 CONCENTRATION WERE GENERATED WHEN THE VENTILATOR WAS USED IN TANDEM WITH A HIGH FREQUENCY JET VENTILATOR (HFJV). THERE WAS NO PATIENT HARM. IMPORTER REF. #: (B)(4). MANUFACTURER REF. #: (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 739992 | SERVO-U | VENTILATOR, CONTINUOUS, FACILITY USE | CBK | MAQUET CRITICAL CARE AB |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |