VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2018-75705
- Event Type
- Injury
- Date Received
- September 7, 2018
- Report Date
- August 23, 2018
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K022269
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TU
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. NO SPECIFIC PATIENT INFORMATION REGARDING EVENTS HAS BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCT (VICRYL SUTURE) INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT(VICRYL SUTURE)S USED IN THIS PROCEDURE? CITATION: JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY. 2014; 21: 650¿655. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE TITLE: "COMPARISON OF THE USE OF LIGASURE, HALO PKS CUTTING FORCEPS, AND ENSEAL TISSUE SEALER IN TOTAL LAPAROSCOPIC HYSTERECTOMY: A RANDOMIZED TRIAL". AUTHORS: HAKAN AYTAN, MD*, HAKAN NAZIK, MD, RAZIYE NARIN, MD, MURAT API, MD, AND EKREM C. TOK, MD. CITATION: JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY. 2014; 21: 650¿655. DOI: HTTP://DX.DOI.ORG/10.1016/J.JMIG.2014.01.010. THERE ARE MANY INSTRUMENTS WITH DIFFERENT ENERGY MODALITIES OR WITH DIFFERENT PROPERTIES THAT ARE AVAILABLE FOR USE IN TOTAL LAPAROSCOPIC HYSTERECTOMY. THE AIM OF THIS RANDOMIZED PROSPECTIVE STUDY WAS TO COMPARE THE USE OF LIGASURE (15 PATIENTS; AGE: 48.6 ± 6.4; BMI: 31.1 ± 4.9), HALO PKS CUTTING FORCEPS (15 PATIENTS; AGE: 50.2 ± 8.7; BMI: 29.7 ± 5.6), AND ENSEAL TISSUE SEALER (ETHICON; 15 PATIENTS; AGE: 51.2 ± 7.4; BMI: 30.7 ± 4.2) IN TOTAL LAPAROSCOPIC HYSTERECTOMY WITH RESPECT TO OPERATION TIME AND BLOOD LOSS AS MAIN OUTCOMES. A TOTAL OF 45 PATIENTS WITH THE INDICATION OF HYSTERECTOMY WERE RANDOMIZED INTO 3 GROUPS FOR TOTAL LAPAROSCOPIC HYSTERECTOMY. DURING THE PROCEDURE, THE UTEROVESICAL PERITONEUM WAS INCISED. THE UTERINE ARTERIES WERE IDENTIFIED AND TRANSECTED. ALL THESE STEPS WERE PERFORMED USING LIGA-SURE, HALO PKS, OR ENSEAL TISSUE SEALER (ETHICON). IN ALL GROUPS, THE VAGINAL VAULT WAS CLOSED LAPAROSCOPICALLY WITH CONTINUOUS SUTURING BY USING VICRYL 1-0 SUTURE (ETHICON). IN THE ENSEAL GROUP, REPORTED COMPLICATIONS INCLUDED BLEEDING (N-2) WHICH REQUIRED CONVENTIONAL BIPOLAR ELECTROSURGERY TO CONTROL THE BLEEDING AND BLADDER INJURY (N-1) WHICH WAS SUTURED LAPAROSCOPICALLY. IN CONCLUSION, THE DATA INDICATE THAT THE 3 BIPOLAR PLATFORMS SHOWED SIMILAR PERFORMANCES IN TLH. THESE INSTRUMENTS WERE NOT DETERMINED TO BE INDEPENDENT PREDICTORS OF OPERATING TIME AND AMOUNT OF BLOOD LOSS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 695223 | VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |