FDA Adverse Event Injury Summary report: N

UNKNOWN CABLE ATTACHMENT

MDR report key: 7836816 · Received August 31, 2018

Report

Report Number
0001825034-2018-08141
Event Type
Injury
Date Received
August 31, 2018
Date of Event
February 12, 2016
Report Date
September 5, 2018
Manufacturer
ZIMMER BIOMET, INC.
Product Code
JDQ
PMA / PMN Number
PN/A
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
SP
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

THE IMPLANT DATE WAS ADDED. ADDITIONAL INFORMATION RECEIVED HAS NO CHANGES TO THE PREVIOUSLY REPORTED INVESTIGATION RESULTS.

Additional Manufacturer Narrative · 1

(B)(4). CONCOMITANT PRODUCTS: 22-301310 ARCOS CON SZ A HI 50MM HA 860790; 22-301014 ARCOS 14X250MM SPL TPR DIST HA 752090; PT-125464 REGENEREX ACET SHELL 64ODX54ID 464070; XL-223652 HWAL ARCOMXL ALLPOLY 36IDX52OD 555790; 103531 TI LOW PROFILE SCREW 6.5X20MM 289902; 103531 TI LOW PROFILE SCREW 6.5X20MM 2888144; 103532 BM ACET LP DOME SCW TI S/TAP DIA6.5X25MM 2901771; 103532 BM ACET LP DOME SCW TI S/TAP DIA6.5X25MM 2578544; 103532 BM ACET LP DOME SCW TI S/TAP DIA6.5X25MM 2909284; 103533 TI LOW PROFILE SCREW 6.5X30MM 2915885; UNKNOWN CABLE ATTACHMENT; UNKNOWN HEAD. (B)(6). THE COMPLAINT IS CONFIRMED AS THE FOLLOW UP VISIT NOTES WERE PROVIDED. DEVICE HISTORY RECORDS WERE REVIEWED AND IDENTIFIED NO DEVIATIONS AND/OR ANOMALIES RELATED TO THE REPORTED EVENT. X-RAYS WERE RECEIVED AND REVIEWED BY MMI. OVERALL FIT AND ALIGNMENT OF THE IMPLANTS IS APPROPRIATE. NO DEFINITE EVIDENCE FOR WEAR. NO METALLIC PARTICLES ARE SEEN. OF NOTE, ON SEVERAL OF THE IMAGES, MEDIAL TO THE PROXIMAL FEMORAL DIAPHYSIS, THERE IS EVIDENCE OF FRAGMENTS PRESENT, UNCERTAIN ETIOLOGY, POSSIBLY WIRE HOWEVER THIS IS UNCONFIRMED. ON SEVERAL OF THE IMAGES, THERE IS LINEAR LUCENCY ALONG THE LATERAL ASPECT OF THE PROXIMAL TO MID LEFT FEMORAL DIAPHYSIS SUGGESTING INCOMPLETE FRACTURE. TIP OF THE FEMORAL COMPONENT IS NOT SEEN ON ANY OF THE IMAGES LIMITING EVALUATION. ROOT CAUSE COULD NOT BE DETERMINED WITH INFORMATION AVAILABLE. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE ASSOCIATED REPORTS: 0001825034 - 2017 - 10919, 0001825034 - 2017 - 10920, 0001825034 - 2017 - 10922, 0001825034 - 2017 - 10923, 0001825034 - 2018 - 08142.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING POST OPERATIVE PAIN AFTER TWO YEAR TEN MONTHS POST REVISION SURGERY DUE TO INFECTION. NO ADDITIONAL INFORMATION IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
678131 UNKNOWN CABLE ATTACHMENT TRAUMA, CABLES JDQ ZIMMER BIOMET, INC. N/A NI

Patients

Seq Age Sex Outcome Treatment
1 82 YR Other