FDA Adverse Event Injury Summary report: N

ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN

MDR report key: 7805249 · Received August 22, 2018

Report

Report Number
2210968-2018-75322
Event Type
Injury
Date Received
August 22, 2018
Report Date
August 2, 2018
Manufacturer
ETHICON INC.
Product Code
GAT
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
TU
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCT (ETHIBOND SUTURE) INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (ETHIBOND SUTURE) USED IN THIS PROCEDURE? CITATION: EUR J ORTHOP SURG TRAUMATOL (2015) 25:827¿832, DOI 10.1007/S00590-015-1617-2, PUBLISHED ONLINE: 11 MARCH 2015 CITATION: REV ASSOC MED BRAS 2015; 61(4):341-346 (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE "TITLE : ANATOMIC LOCKING PLATE AND CORACOCLAVICULAR STABILIZATION WITH SUTURE ENDO-BUTTON TECHNIQUE IS SUPERIOR IN THE TREATMENT OF NEER TYPE II DISTAL CLAVICLE FRACTURES" AUTHOR: MUSTAFA SEYHAN, BARIS KOCAOGLU, GORKEM KIYAK, AREL GERELI, METIN TURKMEN CITATION: EUR J ORTHOP SURG TRAUMATOL (2015) 25:827¿832, DOI 10.1007/S00590-015-1617-2, PUBLISHED ONLINE: 11 MARCH 2015. THE PURPOSE OF THIS RETROSPECTIVE STUDY WAS TO COMPARE THE CLINICAL RESULTS OF THREE DIFFERENT FIXATION TECHNIQUES FOR THE TREATMENT OF NEER TYPE IIB FRACTURES. THERE WERE 36 PATIENTS WITH NEER TYPE IIB FRACTURES TREATED WERE INCLUDED IN THE STUDY AND EVALUATED. PATIENTS WERE DIVIDED INTO THREE GROUPS ACCORDING TO SURGICAL CHOICE THAT WAS PERFORMED: TENSION BAND AND CORACOCLAVICULAR SUTURE STABILIZATION WITH K-WIRES WAS DEFINED AS GROUP 1 (10 PATIENTS; 6 MALES AND 4 FEMALES, AGE RANGE: 26 TO 44), ANATOMIC LOCKING PLATE AND CORACOCLAVICULAR STABILIZATION WITH SCREW WAS DEFINED AS GROUP 2 (12 PATIENTS; 9 MALES AND 3 FEMALES, AGE RANGE: 34 TO 41), AND ANATOMIC LOCKING PLATE AND CORACOCLAVICULAR STABILIZATION WITH SUTURE ENDO-BUTTON (LPES) WAS DEFINED AS GROUP 3 (14 PATIENTS; 10 MALES AND 4 FEMALES, AGE RANGE: 20 TO 55). MEAN FOLLOW-UP PERIOD WAS 32.4 MONTHS. DURING THE PROCEDURE IN THE TENSION BAND AND CORACOCLAVICULAR SUTURE STABILIZATION WITH K-WIRES (TBKWS) TECHNIQUE, NO: 5 ETHIBOND SUTURE PASSED UNDER CORACOID PROCESS AND OVER MEDIAL CLAVICLE WHILE HOLDING THE MEDIAL FRAGMENT REDUCED. A GROOVE UNDER CORACOID PROCESS WAS MADE TO AVOID SLIPPAGE, AND A SECURE KNOT WAS MADE UNDER TENSION AFTER FRACTURE REDUCTION. TWO 2 MM K-WIRES INSERTED FROM ACROMION THROUGH FRACTURE SITE, AND CERCLAGE WIRE TENSION BAND TECHNIQUE WAS APPLIED TO SECURE THE FIXATION FOR OSTEOSYNTHESIS. IN TBKWS GROUP, FIVE PATIENTS SUFFERED FROM DISCOMFORT CAUSED BY SKIN EROSION DUE TO PIN MIGRATION WITH RESIDUAL DISPLACEMENT NOTED IN THREE OF THEM. IN THIS GROUP, ONE NONUNION AND TWO-DELAYED UNION WAS REPORTED. FOR THAT REASON, SECOND SURGERY WAS PERFORMED TO REMOVE DISPLACED PINS. THIRD SURGERY WAS PERFORMED FOR DELAYED AND NONUNION CASES. BOTH UNION TIME AND COMPLICATION RATES SHOWED THAT K-WIRE FIXATION WITH ETHIBOND SUTURE AUGMENTATION WAS NOT ENOUGH TO RESIST THREE-DIMENSIONAL LOADS ON CORACOCLAVICULAR AREA AND DISTAL CLAVICLE. IN CONCLUSION, ANATOMIC LOCKING PLATE AND CORACOCLAVICULAR STABILIZATION WITH SUTURE ENDO-BUTTON TECHNIQUE PROVIDED MORE STABLE AND BIOMECHANICALLY SUPERIOR FIXATION AMONG OTHER TECHNIQUES WITH LOW COMPLICATION RATES IN THE TREATMENT OF NEER TYPE IIB FRACTURES. IT ALSO REDUCES THE RATE OF REOPERATION BY PROVIDING STABLE OSTEOSYNTHESIS WITHOUT COMPROMISING PHYSIOLOGY OF SHOULDER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
648411 ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN SUTURE, NONABSORBABLE, SYNTHETIC GAT ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention LOCKING PLATES, SCREWS, K WIRES