ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN
Report
- Report Number
- 2210968-2018-75120
- Event Type
- Injury
- Date Received
- August 13, 2018
- Report Date
- July 23, 2018
- Manufacturer
- ETHICON INC.
- Product Code
- GAT
- PMA / PMN Number
- K946173
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (ETHIBOND SUTURE) USED IN THIS PROCEDURE? CITATION: ARCH ORTHOP TRAUMA SURG (2013) 133:1361¿1366; DOI 10.1007/S00402-013-1819-1. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE TITLE : HIGH COMPLICATION RATE FOLLOWING DISTAL BICEPS REFIXATION WITH CORTICAL BUTTON AUTHOR: MARC BANERJEE ¿ SVEN SHAFIZADEH ¿ BERTIL BOUILLON ¿ THORSTEN TJARDES ¿ ARASCH WAFAISADE ¿ MAURICE BALKE CITATION: ARCH ORTHOP TRAUMA SURG (2013) 133:1361¿1366; DOI 10.1007/S00402-013-1819-1. THE AIM OF THIS RETROSPECTIVE ANALYSIS WAS TO ASSESS THE FUNCTIONAL RESULTS AND ANY COMPLICATIONS RELATED TO THE TRANSOSSEOUS BUTTON FIXATION TECHNIQUE. BETWEEN 2004 AND 2011, 32 MALE PATIENTS WITH DISTAL BICEPS TENDON RUPTURE UNDERWENT OPERATIVE TREATMENT IN CORTICAL BUTTON TECHNIQUE. IN THE PROCEDURE, THE DISTAL END OF THE TORN BICEPS TENDON WAS WHIP-STITCHED USING A RUNNING BASEBALL STITCH WITH TWO NO. 3 ETHIBOND SUTURES WHICH WERE TIED ON A CORTICAL BUTTON WITH A DISTANCE OF ABOUT 2 MM AWAY FROM THE END OF THE TENDON. AT AN AVERAGE FOLLOW-UP OF 36.1 MONTHS, COMPLICATIONS INCLUDED HETEROTROPHIC OSSIFICATION (N=3) IN WHICH IN ONE NEEDED TO BE PARTIALLY REMOVED DUE TO SEVERE OSSIFICATION, RE-RUPTURE OF THE DISTAL BICEPS TENDON (N=1) IN WHICH THIS PATIENT UNDERWENT TENDON REPAIR IN CORTICAL BUTTON TECHNIQUE, WOUND HEALING DISORDER (N=2) OF WHICH ONE HAD TO BE REVISED, HYPERTROPHIC SCAR (N=1), AND ENDOBUTTON DISLOCATION (N=1) WHICH WAS REVISED 10 DAYS AFTER SURGERY. THE MOST COMMON COMPLICATION IN THE PRESENT STUDY WAS NEURAPRAXIA OF THE POSTERIOR INTEROSSEOUS NERVE. IT WAS OUR INTENTION TO HAVE THE GREATEST POSSIBLE INTRAOSSEOUS COURSE OF THE TENDON BY DRILLING OBLIQUE WITH THE DRILL DIRECTED DISTALLY; HOWEVER, THIS MAY HAVE CAUSED THE NERVE DAMAGE AS THE NERVE CAN BE TRAPPED BETWEEN THE BUTTON AND THE RADIUS. THE COMPLICATION RATE OF DISTAL BICEPS TENDON FIXATION USING TRANSOSSEOUS SUTURES STABILISED WITH BUTTONS WAS AS HIGH AS 33 %. IN THE AUTHORS¿ OPINION, IMPROVING SURGICAL SKILLS, INCLUDING KNOWLEDGE OF ANATOMY, THE HANDLING OF RETRACTORS, THE DRILLING DIRECTION AND KNOWLEDGE OF SPECIFIC PITFALLS RELATED TO THE TYPE OF FIXATION ARE MANDATORY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 618533 | ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN | SUTURE, NONABSORBABLE, SYNTHETIC | GAT | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |