FDA Adverse Event Injury Summary report: N

NYLON SUTURE UNKNOWN PRODUCT

MDR report key: 7765215 · Received August 8, 2018

Report

Report Number
2210968-2018-75027
Event Type
Injury
Date Received
August 8, 2018
Report Date
July 20, 2018
Manufacturer
ETHICON INC.
Product Code
GAR
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (ETHIBOND OR NYLON SUTURE) USED IN THIS PROCEDURE? CITATION: J RECONSTR MICROSURG. 2014; 30: 581 584. DOI: HTTP://DX.DOI.ORG/10.1055/S-0034-1383427. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE TITLE : MICROVASCULAR PENILE REPLANTATION UTILIZING THE DEEP INFERIOR EPIGASTRIC VESSELS AUTHOR: MARK M. LEYNGOLD, MD, CARLOS M. RIVERA-SERRANO, MD CITATION: J RECONSTR MICROSURG. 2014; 30: 581 584. DOI: HTTP://DX.DOI.ORG/10.1055/S-0034-1383427. TRAUMATIC PENILE AMPUTATION IS AN UNCOMMON OCCURRENCE DESCRIBED IN PSYCHIATRIC PATIENTS WITH ACUTE PSYCHOSIS, BUT CAN ALSO BE A CONSEQUENCE OF ACCIDENTS, CIRCUMCISION, ASSAULT OR DOMESTIC VIOLENCE. A (B)(6)MALE PRISONER WITH A HISTORY OF GENDER IDENTITY DISORDER AND SCHIZOPHRENIA WAS RUSHED TO OUR HOSPITAL AFTER A SELF-INFLICTED PENILE AMPUTATION WITH A KNIFE. DURING THE SURGICAL PROCEDURE, THE PROXIMAL AND DISTAL ARTERIAL TO SAPHENOUS VEIN ANASTOMOSIS WERE HAND SEWN WITH AN INTERRUPTED NYLON 8-O SUTURE WITH BV130¿5 NEEDLE (ETHICON) UNDER 3.5 LOOP MAGNIFICATION. PENIS WAS WELL PERFUSED WITH AUDIBLE EXTERNAL DOPPLER SIGNALS OVER THE GLANS AFTER COMPLETION OF ALL ANASTOMOSIS. ABDOMINAL FASCIA WAS REPAIRED WITH AN ETHIBOND 0 SUTURE (ETHICON) LEAVING A SMALL FASCIAL DEFECT FOR THE VESSELS. REPORTED COMPLICATIONS INCLUDED PENILE REPLANT CONGESTION ON POST-OPERATIVE DAY 1 WHICH REQUIRED MEDICINAL LEECH THERAPY AND PENILE SKIN NECROSIS WHICH REQUIRED DEBRIDEMENT AND SKIN GRAFTING. THE DEEP INFERIOR EPIGASTRIC VESSELS OFFER A ROBUST FLOW AND ARE SUITABLE AS RECIPIENT VESSELS IN CASES OF PENILE REPLANTATION WHEN LOCAL ALTERNATIVES ARE UNAVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
605922 NYLON SUTURE UNKNOWN PRODUCT SUTURE, NONABSORBABLE, SYNTHETIC GAR ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 30 YR Required Intervention