ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN
Report
- Report Number
- 2210968-2018-75026
- Event Type
- Injury
- Date Received
- August 8, 2018
- Report Date
- July 20, 2018
- Manufacturer
- ETHICON INC.
- Product Code
- GAT
- PMA / PMN Number
- K946173
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (ETHIBOND OR NYLON SUTURE) USED IN THIS PROCEDURE? CITATION: J RECONSTR MICROSURG. 2014; 30: 581 584. DOI: HTTP://DX.DOI.ORG/10.1055/S-0034-1383427. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE TITLE : MICROVASCULAR PENILE REPLANTATION UTILIZING THE DEEP INFERIOR EPIGASTRIC VESSELS AUTHOR: MARK M. LEYNGOLD, MD, CARLOS M. RIVERA-SERRANO, MD CITATION: J RECONSTR MICROSURG. 2014; 30: 581 584. DOI: HTTP://DX.DOI.ORG/10.1055/S-0034-1383427. TRAUMATIC PENILE AMPUTATION IS AN UNCOMMON OCCURRENCE DESCRIBED IN PSYCHIATRIC PATIENTS WITH ACUTE PSYCHOSIS, BUT CAN ALSO BE A CONSEQUENCE OF ACCIDENTS, CIRCUMCISION, ASSAULT OR DOMESTIC VIOLENCE. A (B)(6) MALE PRISONER WITH A HISTORY OF GENDER IDENTITY DISORDER AND SCHIZOPHRENIA WAS RUSHED TO OUR HOSPITAL AFTER A SELF-INFLICTED PENILE AMPUTATION WITH A KNIFE. DURING THE SURGICAL PROCEDURE, THE PROXIMAL AND DISTAL ARTERIAL TO SAPHENOUS VEIN ANASTOMOSIS WERE HAND SEWN WITH AN INTERRUPTED NYLON 8-0 SUTURE WITH BV130¿5 NEEDLE (ETHICON) UNDER 3.5 LOOP MAGNIFICATION. PENIS WAS WELL PERFUSED WITH AUDIBLE EXTERNAL DOPPLER SIGNALS OVER THE GLANS AFTER COMPLETION OF ALL ANASTOMOSIS. ABDOMINAL FASCIA WAS REPAIRED WITH AN ETHIBOND 0 SUTURE (ETHICON) LEAVING A SMALL FASCIAL DEFECT FOR THE VESSELS. REPORTED COMPLICATIONS INCLUDED PENILE REPLANT CONGESTION ON POST-OPERATIVE DAY 1 WHICH REQUIRED MEDICINAL LEECH THERAPY AND PENILE SKIN NECROSIS WHICH REQUIRED DEBRIDEMENT AND SKIN GRAFTING. THE DEEP INFERIOR EPIGASTRIC VESSELS OFFER A ROBUST FLOW AND ARE SUITABLE AS RECIPIENT VESSELS IN CASES OF PENILE REPLANTATION WHEN LOCAL ALTERNATIVES ARE UNAVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 605921 | ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN | SUTURE, NONABSORBABLE, SYNTHETIC | GAT | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 30 YR | Required Intervention |