FDA Adverse Event Injury Summary report: N

ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN

MDR report key: 7764487 · Received August 8, 2018

Report

Report Number
2210968-2018-75018
Event Type
Injury
Date Received
August 8, 2018
Report Date
July 20, 2018
Manufacturer
ETHICON INC.
Product Code
GAT
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (ETHIBOND OR VICRYL SUTURE) USED IN THIS PROCEDURE? CITATION: ACTA ORTHOP TRAUMATOL TURC 2013; 47(5):307-310; DOI:10.3944/AOTT.2013.3015. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE TITLE : THE COMPARISON OF ETHIBOND SUTURES AND SEMITENDINOSUS AUTOGRAFT IN THE SURGICAL TREATMENT OF ACROMIOCLAVICULAR DISLOCATION. AUTHOR: MOHSEN MARDANI-KIVI, AHMADREZA MIRBOLOOK, MOSTAFA SALARIYEH, KEYVAN HASHEMI-MOTLAGH, KHASHAYAR SAHEB-EKHTIARI. CITATION: ACTA ORTHOP TRAUMATOL TURC 2013; 47(5):307-310; DOI:10.3944/AOTT.2013.3015. THE AIM OF THIS ANALYTICAL CROSS-SECTIONAL STUDY WAS TO EXAMINE AND COMPARE THE OUTCOMES OF ACROMIOCLAVICULAR JOINT (ACJ) RECONSTRUCTION WITH EITHER NO. 5 ETHIBOND SUTURE OR SEMITENDINOSUS AUTOGRAFT IN THE TREATMENT OF AC DISLOCATIONS. BETWEEN THE PERIODS OF SEPTEMBER 2006 AND SEPTEMBER 2009, THERE WERE 39 PATIENTS (35 MALES AND 4 FEMALES; MEAN AGE: 32.6±11.8 YEARS), WITH COMPLETE ACJ JOINT DISLOCATION (TYPE 3 TO 6). TWENTY ONE PATIENTS UNDERWENT RECONSTRUCTION USING NO. 5 ETHIBOND SUTURE (ETHICON INC., SOMERVILLE, NJ, USA) (GROUP A) AND 18 PATIENTS USING SEMITENDINOSUS TENDON AUTOGRAFT (GROUP B). DURING THE PROCEDURE IN GROUP A, A TWO-FOLDED NO. 5 ETHIBOND SUTURE WAS DRIVEN BENEATH THE CORACOID AND PASSED THROUGH TWO DRILL HOLES ON THE CLAVICLE SEPARATED BY ONE CENTIMETER. THE SUTURES WERE TIED AFTER ANATOMICAL REDUCTION OF AC JOINT. IN GROUP B, FOLLOWING ANATOMICAL REDUCTION OF THE AC JOINT THE TWO TIPS OF THE TENDON WERE TIED UP ON THE CLAVICLE WITH NO. 1 VICRYL SUTURE. ONLY 11 PATIENTS IN GROUP A AND 10 PATIENTS IN GROUP B HAD A MILD PIN TRACT INFECTION WHICH WERE ALL COMPLETELY RECOVERED FOLLOWING THE REMOVAL OF THE PINS. IN CONCLUSION, TWO DIFFERENT SURGICAL TECHNIQUES PROVIDED SIMILAR RESULTS IN THE RECONSTRUCTION OF THE AC DISLOCATION IN OUR STUDY. THE DEGREE OF REDUCTION, SHOULDER FUNCTION AND PATIENT SATISFACTION WERE SIMILAR. HOWEVER, AVOIDING THE MORBIDITY OF GRAFT HARVESTING IS AN ADVANTAGE OF NO. 5 ETHIBOND SUTURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
606141 ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN SUTURE, NONABSORBABLE, SYNTHETIC GAT ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention