FDA Adverse Event Injury Summary report: N

ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN

MDR report key: 7759980 · Received August 7, 2018

Report

Report Number
2210968-2018-74990
Event Type
Injury
Date Received
August 7, 2018
Report Date
July 30, 2018
Manufacturer
ETHICON INC.
Product Code
GAT
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
TX, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). CITATION: 2009 BJU INTERNATIONAL 105, 1440 ¿ 1444 / DOI:10.1111/J.1464-410X.2009.08991.X. [(B)(4)].

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: PENOSCROTAL PLICATION AS A UNIFORM APPROACH TO RECONSTRUCTION OF PENILE CURVATURE". AUTHORS: DANIEL D. DUGI III AND ALLEN F. MOREY. CITATION: 2009 BJU INTERNATIONAL 105, 1440 ¿ 1444 / DOI:10.1111/J.1464-410X.2009.08991.X. THIS STUDY AIMED TO PRESENT THE AUTHORS EXPERIENCE WITH PENOSCROTAL PLICATION (PSP) AS A UNIFORM SURGICAL APPROACH FOR MEN WITH SIGNIFICANT PENILE CURVATURE AND INTACT ERECTILE FUNCTION. DURING A 4-YEAR PERIOD FROM 2005 TO 2009, 48 MALE PATIENTS (MEDIAN AGE OF 58.7 YEARS [24-71 YEARS]) WITH SIGNIFICANT PENILE CURVATURE UNDERWENT TUNICA ALBUGINEA PSP. IN THE PROCEDURE, ETHIBOND SUTURES WERE PLACED OPPOSITE THE AREA OF MAXIMUM CURVATURE FOR WHICH EACH SUTURE SPANS A TOTAL OF ¿15 MM. THE PROCEDURE WAS CONSIDERED COMPLETE WHEN ALL MEMBERS OF THE SURGICAL TEAM AGREED THAT THE CURVATURE HAD BEEN COMPLETELY CORRECTED. IMMEDIATELY POSTOPERATIVE, MILD PAIN WITH ERECTION WAS COMMON IN THE PATIENTS, BUT WAS GENERALLY SELF-LIMITED. AT 6 WEEKS AFTER SURGERY, 3 PATIENTS HAD ERECTILE PAIN FOR WHICH TWO HAD A SUTURE RELEASED PROCEDURE. TWO PATIENTS WERE DISSATISFIED WITH THE STRAIGHTENING/RECURRENT OF CURVATURE; A YOUNG MAN WITH CONGENITAL PENILE CURVATURE WHO HAD REPEAT PLICATION, AND A PATIENT WITH PEYRONIE¿S DISEASE HAD CONTINUED CURVATURE AND WORSENED ERECTILE DYSFUNCTION TREATED WITH INSERTION OF A PENILE PROSTHESIS. THE AUTHORS CAUTIONED THAT MANY SUTURES (UP TO 17) MIGHT BE REQUIRED TO EFFECTIVELY STRAIGHTEN COMPLEX DEFORMITIES AND THAT TRANSIENTLY PAINFUL ERECTIONS MIGHT BE MORE LIKELY AFTER SURGERY. THE FINDINGS ADD TO AN EMERGING BODY OF EVIDENCE THAT SHORTENING OF THE PENIS OCCURS PRIMARILY DUE TO THE PEYRONIE¿S PLAQUE FORMATION AND NOT DUE TO PLICATION SURGERY. PSP IS A SAFE AND EFFECTIVE TECHNIQUE WHICH IS WIDELY APPLICABLE FOR RECONSTRUCTING PENILE SHAFT CURVATURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
601425 ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN SUTURE, NONABSORBABLE, SYNTHETIC GAT ETHICON INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention