BARDEX® LUBRI-SIL® I.C. ALL-SILICONE FOLEY CATHETER
Report
- Report Number
- 1018233-2018-03392
- Event Type
- Malfunction
- Date Received
- August 6, 2018
- Date of Event
- July 17, 2018
- Report Date
- September 12, 2018
- Manufacturer
- C.R. BARD, INC. (COVINGTON) -1018233
- Product Code
- MJC
- PMA / PMN Number
- K984136
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- NURSE
Narratives
THE DEVICE WAS NOT RETURNED FOR EVALUATION. THE LOT NUMBER IS UNKNOWN; THEREFORE, THE DEVICE HISTORY RECORD COULD NOT BE REVIEWED. THE INSTRUCTIONS FOR USE STATE THE FOLLOWING: "PEEL TO OPEN LUBRI-SIL¿I.C. BACTI-GUARD®* SILVER/HYDROGEL FOLEY CATHETER WITH RADIOPAQUE STRIPE STERILE: UNLESS PACKAGE IS OPENED OR DAMAGED. WARNING: ON CATHETER, DO NOT USE OINTMENTS OR LUBRICANTS HAVING PETROLATUM BASE. THEY WILL DAMAGE SILICONE AND MAY CAUSE THE BALLOON TO BURST. CAUTION: DO NOT ASPIRATE URINE THROUGH DRAINAGE FUNNEL WALL. STORAGE: STORE CATHETERS AT ROOM TEMPERATURE AWAY FROM DIRECT EXPOSURE TO LIGHT, PREFERABLY IN THE ORIGINAL BOX. NOTE: AGGRESSIVE TRACTION, PARTICULARLY IN THE PRESENCE OF SUTURING, IS NOT RECOMMENDED FOR 100% SILICONE FOLEY CATHETERS. SINGLE PATIENT USE ONLY. DO NOT REUSE. DO NOT RESTERILIZE. FOR UROLOGICAL USE ONLY. VALVE TYPE: USE LUER SLIP TIP SYRINGE. DO NOT USE NEEDLE. CATHETERS SHOULD BE REPLACED IN ACCORDANCE WITH THE CDC GUIDELINE ¿GUIDELINE FOR PREVENTION OF CATHETER-ASSOCIATED URINARY TRACT INFECTION¿. AT THE ONSET OR FIRST SIGNS OF A URINARY TRACT INFECTION, CATHETER ENCRUSTATION, OR ANY OTHER CATHETER-RELATED ADVERSE EFFECT, THE CATHETER SHOULD BE REPLACED. RECOMMENDED INFLATION CAPACITIES 3CC BALLOON: USE 5CC STERILE WATER 5CC BALLOON: USE 10CC STERILE WATER 30CC BALLOON: USE 35CC STERILE WATER DO NOT EXCEED RECOMMENDED CAPACITIES. WARNING: AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. HANDLE AND DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. TO DEFLATE CATHETER BALLOON: GENTLY INSERT A SYRINGE IN THE CATHETER VALVE. NEVER USE MORE FORCE THAN IS REQUIRED TO MAKE THE SYRINGE ¿STICK¿ IN THE VALVE. IF YOU NOTICE SLOW OR NO DEFLATION, RE-SEAT THE SYRINGE GENTLY. ALLOW THE BALLOON TO DEFLATE SLOWLY ON ITS OWN. DO NOT ASPIRATE OR MANUALLY ACCELERATE THE DEFLATION OF THE BALLOON. IF PERMITTED BY HOSPITAL PROTOCOL, THE VALVE ARM MAY BE SEVERED. IF THIS FAILS, CONTACT ADEQUATELY TRAINED PROFESSIONAL FOR ASSISTANCE, AS DIRECTED BY HOSPITAL PROTOCOL. SHOULD BALLOON RUPTURE OCCUR, CARE SHOULD BE TAKEN TO ASSURE THAT ALL BALLOON FRAGMENTS HAVE BEEN REMOVED FROM THE PATIENT. VISUALLY INSPECT THE PRODUCT FOR ANY IMPERFECTIONS OR SURFACE DETERIORATION PRIOR TO USE."
IT WAS REPORTED THAT THE CATHETER BALLOON WAS UNABLE TO BE INFLATED DURING THE PRETEST. ANOTHER CATHETER WAS USED.
THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. THE INFORMATION PROVIDED BY BARD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BARD. THE DEVICE WAS NOT RETURNED.
IT WAS REPORTED THAT THE CATHETER BALLOON WAS UNABLE TO BE INFLATED DURING THE PRETEST. ANOTHER CATHETER WAS USED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 594431 | BARDEX® LUBRI-SIL® I.C. ALL-SILICONE FOLEY CATHETER | FOLEY CATHETER (SILICON) | MJC | C.R. BARD, INC. (COVINGTON) -1018233 | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |