RENU WITH MOISTURELOC MULTI-PURPOSE SOLUTION
Report
- Report Number
- 1313525-2006-00268
- Event Type
- Injury
- Date Received
- October 30, 2006
- Date of Event
- November 1, 2005
- Report Date
- May 17, 2006
- Manufacturer
- BAUSCH & LOMB, INC.
- Product Code
- LPN
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- PHYSICIAN
Narratives
BAUSCH & LOMB INITIATED AN INVESTIGATION THAT EVALUATED THE MANUFACTURING FACILITY ENVIRONMENTAL RECORDS, A REVIEW OF BATCH RECORDS AND TESTING OF RETAIN SAMPLES FOR NUMEROUIS PRODUCED LOTS. ALL OF THE RECORDS INDICATE THERE WERE NO ANOMALIES THAT COULD HAVE BEEN RELATED TO THE REPORT, THERE WERE NO FUSARIUM RECOVERIES FROM THE FACILITY ENVIRONMENTAL MONITORING PROGRAM OF THE ASEPTIC PROCESSING AREAS, AND ALL PRODUCT RELEASE STERILITY EVALUATIONS MET CRITERIA. PRODUCT RETAIN SAMPLE TESTING WAS COMPLETED WHERE LOT NUMBERS WERE AVAILABLE AND INDICATED THAT ALL CHEMICAL AND BIOCIDAL PERFORMANCE WAS EFFECTIVE AGAINST MICROBIAL CHALLENGES AS REQUIRED. THE CONCLUSION OF THIS INVESTIGATION IS THAT SOME ASPECT OF THE MOISTURELOC FORMULA MAY BE INCREASING THE RELATIVE RISK OF FUSARIUM KERATITIS IN UNUSUAL CIRCUMSTANCES. WE ARE CONTINUING TO INVESTIGATE THIS LINK, BUT IN THE MEANTIME, WE ARE TAKING THE MOST RESPONSIBLE ACTION IN THE INTEREST OF OUR CUSTOMERS BY DISCONTINUING THE MOISTURELOC FORMULA AND RECALLING ALL DISTRIBUTED PRODUCT.
A PHONE CALL WAS RECEIVED FROM A DOCTOR AT HOSPITAL IN ANOTHER COUNTRY. HE REPORTS THAT IN 2005, A FEMALE DEVELOPED AN ABSCESS UNDER HER COLORED CONTACT LENS WHICH WAS TREATED WITH CORTICOIDS. AFTER 12 DAYS, CONSUMER WAS TREATED FOR HYPOPION, TYNDALL, ABSCESSES WITH AMPHOTERICINB AND ITRACONAZOLE. SEVEN DAYS LATER, AGGRAVATION WITH SEVERE CORNEAL MELTING AND PERFORATION OCCURRED WITH SUBSEQUENT 30 DAY HOSPITALIZATION. TREATMENT WITH NATAMYCIN AND VORICONAZOLE. THE ULCER HEALED IN 20 DAYS, CONJUNTIVAL COVERING AT 17 DAYS AND 27 DAYS. VISUAL ACUITY LIMITED TO MOVEMENT PERCEPTION AT 2 MONTHS. A GRAFT IS IMPOSSIBLE DUE TO SURFACE OF THE LESION. FUSARIUM IDENTIFIED IN THE CONTACT LENS CASE. THE DOCTOR REPORTS THAT THE CONSUMER HAD POOR HYGEINIC PRACTICES. THE CONSUMER IS NEAR BLINDNESS. NO FURTHER INFORMATION OR ANY MEDICAL DOCUMENTATION AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | RENU WITH MOISTURELOC MULTI-PURPOSE SOLUTION | MULTI-PURPOSE SOLUTION FOR SOFT CONTACT LENSES | LPN | BAUSCH & LOMB, INC. | NA | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 39 YR | Required Intervention |