FDA Adverse Event Injury Summary report: N

UNKNOWN_NOVADAQ_PRODUCT

MDR report key: 7737482 · Received July 31, 2018

Report

Report Number
3012345110-2018-00005
Event Type
Injury
Date Received
July 31, 2018
Date of Event
November 2, 2015
Report Date
July 31, 2018
Manufacturer
NOVADAQ TECHNOLOGIES
Product Code
GCJ
PMA / PMN Number
K150956
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

NOVADAQ TECHNOLOGIES, INC. WAS ACQUIRED BY STRYKER. THIS MDR IS BEING SUBMITTED LATE BECAUSE IT WAS IDENTIFIED DURING THE INTEGRATION AND REMEDIATION ACTIVITIES INITIATED BY STRYKER ENDOSCOPY IN CONJUNCTION WITH THIS ACQUISITION. INITIAL INVESTIGATION BY NOVADAQ OF THE EVENT SHOWED THAT UNDER NORMAL USE CONDITIONS THE ENDOSCOPE IS NOT CAPABLE OF HEATING THE TROCAR PAST 31°C, WHICH IS BELOW THE IEC 60601-1 § 11.1.2.2 THRESHOLD (¿SURFACE TEMPERATURES OF APPLIED PARTS NOT INTENDED TO SUPPLY HEAT TO THE PATIENT MUST NOT SURPASS 41°C WITHOUT FURTHER CONSIDERATION¿). FURTHER INVESTIGATION BY NOVADAQ REVEALED THAT LAPAROSCOPES AND TROCARS CAN INADVERTENTLY SERVE AS ALTERNATIVE CURRENT PATHS FOR CURRENT TO FLOW BACK TO THE NEUTRAL CONDUCTOR WHEN USING MONOPOLAR ELECTROCAUTERY SYSTEMS. THIS CAN RESULT IN ABNORMAL HEAT ENERGY BEING GENERATED AT THE TROCAR, THUS POTENTIALLY CAUSING PATIENT BURNS. THE PINPOINT OPERATOR'S MANUAL INCLUDES A WARNING TO THE USERS THAT STATES THE FOLLOWING: "NOVADAQ RIGID LAPAROSCOPES ARE NOT DESIGNED TO PROVIDE INSULATION AGAINST HIGH-FREQUENCY (HF) ELECTRICAL CURRENTS. TO PREVENT BURNS AND UNINTENDED THERMAL INJURY OF SURROUNDING TISSUE, ACTIVATE ELECTRODES ONLY WHEN VISIBLE THROUGH THE LAPAROSCOPE AND AVOID CONTACT BETWEEN ACTIVE ELECTRODES AND THE LAPAROSCOPE."

Description of Event or Problem · 1

IT WAS REPORTED THAT AT THE COMPLETION OF THE PROCEDURE, A BURN WAS OBSERVED ON THE SKIN AROUND THE PORT. THE NOVADAQ PRODUCT REPORTED IN THE EVENT, THE LAPAROSCOPE, MAY HAVE BEEN A CONTRIBUTING FACTOR TO THE BURN. THE BURN WAS THE RESULT OF A METAL TROCAR, NOT MANUFACTURED BY NOVADAQ, HEATING DURING THE PROCEDURE AND INJURING THE SURROUNDING TISSUE. THE LAPAROSCOPE MAY HAVE AIDED IN THE HEAT TRANSFER FROM EXTENDED TIME IN NIR ILLUMINATION. IT WAS REPORTED THE SURGEON DID NOT BELIEVE THE BURN WAS SERIOUS, HOWEVER IT IS UNKNOWN IF MEDICAL INTERVENTION WAS REQUIRED TO TREAT THE BURN.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
576821 UNKNOWN_NOVADAQ_PRODUCT LAPAROSCOPE, GENERAL & PLASTIC SURGERY GCJ NOVADAQ TECHNOLOGIES

Patients

Seq Age Sex Outcome Treatment
1 Other