FDA Adverse Event Injury Summary report: N

ENDOPATH*STEALTH CIR STAPLER (EXACT CODE UNKNOWN)

MDR report key: 7728190 · Received July 27, 2018

Report

Report Number
3005075853-2018-11642
Event Type
Injury
Date Received
July 27, 2018
Date of Event
January 1, 2017
Report Date
July 3, 2018
Manufacturer
ETHICON ENDO-SURGERY, LLC.
Product Code
GCJ
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). INVESTIGATION SUMMARY AS THE DEVICE WAS NOT RETURNED, AN ANALYSIS INVESTIGATION COULD NOT BE PERFORMED. A CONCLUSION COULD NOT BE REACHED AS TO WHAT MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT. COMPLAINT INFORMATION IS TRENDED ON A REGULAR BASIS TO DETERMINE IF FURTHER INVESTIGATION IS WARRANTED. DEVICE HISTORY: THE LOT/BATCH WAS NOT PROVIDED; THEREFORE, THE MANUFACTURING RECORDS COULD NOT BE REVIEWED.

Description of Event or Problem · 1

TITLE: INDOCYANINE GREEN TISSUE ANGIOGRAPHY AFFECTS ANASTOMOTIC LEAKAGE AFTER ESOPHAGECTOMY. A RETROSPECTIVE, CASE-CONTROL STUDY AUTHORS: IOANNIS KARAMPINISA, ULRICH RONELLENFITSCHB, CHRISTINA MERTENSA, ANDREAS GERKENA, SVETLANA HETJENSC, STEFAN POSTA, PETER KIENLEA, KAI NOWAKA CITATION: INTERNATIONAL JOURNAL OF SURGERY. 2017; 48: 210 214. DOI: HTTPS://DOI.ORG/10.1016/J.IJSU.2017.11.001. OPTIMAL PERFUSION OF THE GASTRIC CONDUIT DURING ESOPHAGECTOMY IS ELEMENTARY FOR THE ANASTOMOTIC HEALING SINCE POOR PERFUSION HAS BEEN ASSOCIATED WITH INCREASED MORBIDITY DUE TO ANASTOMOTIC LEAKS. UNTIL RECENTLY, SURGICAL EXPERIENCE WAS THE MAIN TOOL TO ASSESS THE PERFUSION OF THE ANASTOMOSIS. THE AUTHORS HYPOTHESIZED THAT ANASTOMOSES LOCATED IN THE ZONE OF OPTIMAL ICG PERFUSION OF THE GASTRIC CONDUIT (¿OPTIZONE¿) HAVE A REDUCED ANASTOMOTIC LEAKAGE RATE AFTER ESOPHAGECTOMY. A TOTAL OF 88 PATIENTS WITH PRIMARY ESOPHAGEAL CARCINOMA WHO UNDERWENT ESOPHAGECTOMY IN THE DEPARTMENT AND WERE ENROLLED IN THE STUDY. A TOTAL OF 33 PATIENTS (9 FEMALE AND 24 MALE PATIENTS; AGE RANGE: 65.7 ± 8.5; BMI: 26.8 ± 4.2) WERE OPERATED BETWEEN AUGUST 2014 AND DECEMBER 2016 WITH INTRAOPERATIVE ICG FLUORESCENCE ANGIOGRAPHY. THE RESULTS WERE COMPARED TO A CONSECUTIVE COHORT OF 55 PATIENTS (CONTROL GROUP; 14 FEMALE AND 41 MALE PATIENTS; AGE RANGE: 60.5 ± 8.5; BMI: 25.8 ± 4.3) WHO HAD BEEN OPERATED BETWEEN 2010 AND 2014 WITHOUT INTRAOPERATIVE ICG TISSUE ANGIOGRAPHY. DURING THE SURGICAL PROCEDURE IN BOTH GROUPS, A 3- TO 5-CM WIDE GASTRIC CONDUIT WAS CREATED UNDER PRESERVATION OF THE RIGHT GASTRIC (WHEN POSSIBLE) AND GASTROEPIPLOIC ARTERY. LINEAR STAPLERS WERE USED TO PREPARE THE GASTRIC CONDUIT AND THE STAPLE LINES WERE OVERSEWN WITH PDS 4-0 SUTURES. THE TUBULARIZED GASTRIC CONDUIT WAS BROUGHT UP TO THE POSTERIOR MEDIASTINUM AND A CIRCULAR STAPLER (ETHICON) WAS USED FOR THE ANASTOMOSIS. PATIENTS WITH TUMOR OF THE PROXIMAL OR UPPER THORACIC ESOPHAGUS WERE OPERATED THORACOSCOPICALLY IN PRONE POSITION. AFTER PULL-UP OF THE GASTRIC CONDUIT TO THE NECK, A CERVICAL END TO END HAND-SEWN SINGLE LAYER ANASTOMOSIS WAS PERFORMED. IN THE ICG GROUP, REPORTED COMPLICATIONS INCLUDED MALPERFUSION TOWARDS THE TIP OF THE GASTRIC CONDUIT (N-26) WHICH REQUIRED GASTRIC CONDUIT SHORTENING, SEVERELY STRESSED GASTRIC CONDUIT (N-1) WHICH REQUIRED GASTRIC CONDUIT SHORTENING AND AN INTRATHORACIC ANASTOMOSIS IN THE OPTIZONE WAS PERFORMED AND NO LEAK WAS OBSERVED, AND ANASTOMOTIC LEAKAGE (N-1). IN THE CONTROL GROUP, REPORTED COMPLICATIONS INCLUDED MINOR ANASTOMOTIC LEAKAGE (N-6) WITHOUT NEED FOR FURTHER INTERVENTIONAL TREATMENT, MAJOR CLINICAL LEAKAGE WITH A NECROSIS OF THE GASTRIC CONDUIT (N-3), AND ANASTOMOTIC LEAKAGE (N-1). IT WAS REPORTED THAT ADEQUATE PERFUSION IS ESSENTIAL FOR THE UNCOMPLICATED HEALING OF GASTROINTESTINAL ANASTOMOSES. ICG TISSUE ANGIOGRAPHY REPRESENTS A FEASIBLE AND RELIABLE TECHNICAL SUPPORT IN THE EVALUATION OF THE ANASTOMOTIC PERFUSION AFTER ESOPHAGECTOMY. IN THIS RETROSPECTIVE ANALYSIS, THE AUTHORS OBSERVED A SIGNIFICANT DECREASE IN ANASTOMOTIC LEAKAGE RATE WHEN THE ANASTOMOSIS COULD BE PLACED IN THE ZONE OF GOOD PERFUSION DEFINED BY ICG FLUORESCENCE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
569646 ENDOPATH*STEALTH CIR STAPLER (EXACT CODE UNKNOWN) LAPAROSCOPE, GENERAL AND PLASTIC SURGERY GCJ ETHICON ENDO-SURGERY, LLC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention