CONTOUR TRANSTAR STAPLER SET
Report
- Report Number
- 3005075853-2018-11570
- Event Type
- Injury
- Date Received
- July 26, 2018
- Report Date
- June 29, 2018
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GDW
- UDI-DI
- 20705036002878
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). THE LOT/BATCH WAS NOT PROVIDED; THEREFORE, THE MANUFACTURING RECORDS COULD NOT BE REVIEWED.
IT WAS REPORTED VIA LITERATURE ARTICLE ENTITLED: NEW KID ON THE BLOCK: PERINEAL STAPLED PROLAPSE RESECTION. (PSP) IS IT WORTHWHILE IN THE LONG-TERM?.. AUTHOR : BIANKA HUMMEL, JULIA HARDT, STEPHAN BISCHOFBERGER, FRANC HETZER, RENE WARSCHKOW, MARCEL ZADNIKAR, WALTER BRUNNER, BERNHARD WIDMANN1 & BRUNO SCHMIED, LUKAS MARTI. CITATION: LANGENBECKS ARCH SURG. 2016; 401: 519¿529. DOI: 10.1007/S00423-016-1431-2. PERINEAL STAPLED PROLAPSE RESECTION (PSP) IS A RELATIVELY NEW PROCEDURE USED TO TREAT COMPLETE EXTERNAL RECTAL PROLAPSE. IT WAS DEVELOPED FROM STAPLED TRANSANAL RECTAL RESECTION (STARR) WHICH ALLEVIATES OBSTRUCTED DEFECATION SYNDROME BY REMOVING RECTAL INTUSSUSCEPTION WITH A CONTOUR TRANSTAR STAPLER (ETHICON). THIS STUDY AIMS TO ASSESS LONG-TERM RESULTS AFTER PSP. THE ANALYSIS WAS BASED ON THE 64 CASES OF PSPS (62 FEMALE AND 2 MALE PATIENTS; AGE RANGE: 68.2 TO 84.7 YEARS OLD; BMI: 23.3) PERFORMED CONSECUTIVELY BETWEEN AUGUST 2007 AND OCTOBER 2015 AT THE (B)(6). DURING THE PROCEDURE, THE COMPLETELY EXTRACTED PROLAPSE WAS OPENED WITH A LINEAR STAPLER WITH ONE OR MULTIPLE FIRINGS AND THEN STEPWISE RESECTED WITH CONTOUR TRANSTAR STAPLER (ETHICON) PARALLEL TO THE DENTATE LINE. REPORTED COMPLICATIONS INCLUDED MALFUNCTION OF THE STAPLER IN AN EXCEPTIONALLY THICK AND VULNERABLE PROLAPSE LEADING TO A LARGE DEFECT (N-1) WHICH REQUIRED CONVERSION TO ALTERMEIER¿S RECTOSIGMOIDECTOMY, MINOR DEHISCENCE OF THE STAPLE LINE (N-3) WHICH WAS OVERSEWN WITHOUT FURTHER CONSEQUENCES, AND RECURRENCE OF RECTAL PROLAPSE (N-19) WHICH REQUIRED RE-OPERATION (N-16), ALTEMEIER¿S RECTOSIGMOIDECTOMY IN ANOTHER HOSPITAL (N-1), AND SECOND PSP PROCEDURE (N-2). IT WAS CONCLUDED THAT PSP IS AN EASY-TO-PERFORM PROCEDURE FOR RECTAL PROLAPSE. IT IS ASSOCIATED WITH A LOW MORBIDITY, HIGH PATIENTS¿ SATISFACTION, AND GOOD FUNCTIONAL OUTCOME. IT IS LIKELY TO BE A GOOD ALTERNATIVE TO THE OTHER PERINEAL PROCEDURES SUCH AS ALTEMEIER¿S OR REHN-DELORME¿S PROCEDURE, WHICH ARE MORE COMPLEX TO PERFORM.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 564820 | CONTOUR TRANSTAR STAPLER SET | STAPLE, IMPLANTABLE | GDW | ETHICON ENDO-SURGERY, LLC. | 20705036002878 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |