FDA Adverse Event Malfunction Summary report: N

BARDEX® LUBRI-SIL® I.C. ALL-SILICONE FOLEY CATHETER

MDR report key: 7710590 · Received July 23, 2018

Report

Report Number
1018233-2018-02923
Event Type
Malfunction
Date Received
July 23, 2018
Date of Event
July 3, 2018
Report Date
February 1, 2019
Manufacturer
C.R. BARD, INC. (COVINGTON) -1018233
Product Code
MJC
PMA / PMN Number
K984136
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE WAS NOT RETURNED FOR EVALUATION. THE DEVICE HISTORY RECORD WAS REVIEWED AND FOUND NOTHING THAT COULD HAVE CAUSED OR CONTRIBUTED TO THE REPORTED EVENT. THE INSTRUCTIONS FOR USE STATE THE FOLLOWING: ¿LUBRI-SIL® I.C.®ANTI-MICROBIAL ALL-SILICONE FOLEY CATHETER WITH BARD®HYDROGEL AND BACTI-GUARD®* SILVER ALLOY COATING INFECTION CONTROL ALL-SILICONE FOLEY CATHETER 100% LATEX FREE WARNING: ON CATHETER, DO NOT USE OINTMENTS OR LUBRICANTS HAVING A PETROLATUM BASE. THEY WILL DAMAGE SILICONE AND MAY CAUSE BALLOON TO BURST. WARNING: AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. HANDLE AND DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. CAUTION: FEDERAL (U.S.A.) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. CAUTION: DO NOT ASPIRATE URINE THROUGH DRAINAGE FUNNEL WALL. STORAGE: STORE CATHETERS AT ROOM TEMPERATURE AWAY FROM DIRECT EXPOSURE TO LIGHT, PREFERABLY IN THE ORIGINAL BOX. NOTE: AGGRESSIVE TRACTION PARTICULARLY IN THE PRESENCE OF SUTURING, IS NOT RECOMMENDED FOR 100% SILICONE FOLEY CATHETERS. STERILE UNLESS PACKAGE IS OPENED OR DAMAGED. SINGLE PATIENT USE ONLY. DO NOT REUSE. DO NOT RESTERILIZE. FOR UROLOGICAL USE ONLY. VALVE TYPE: USE LUER SLIP TIP SYRINGE. DO NOT USE NEEDLE. CATHETERS SHOULD BE REPLACED IN ACCORDANCE WITH THE CDC GUIDELINE ¿GUIDELINE FOR PREVENTION OF CATHETER-ASSOCIATED URINARY TRACT INFECTION.¿ AT THE ONSET OR FIRST SIGNS OF A URINARY TRACT INFECTION, CATHETER ENCRUSTATION, OR ANY OTHER CATHETER-RELATED ADVERSE EFFECT, THE CATHETER SHOULD BE REPLACED. TO DEFLATE CATHETER BALLOON: GENTLY INSERT SYRINGE IN THE CATHETER VALVE. NEVER USE MORE FORCE THAN IS REQUIRED TO MAKE THE SYRINGE ¿STICK¿ IN THE VALVE. IF YOU NOTICE SLOW OR NO DEFLATION, RE-SEAT THE SYRINGE GENTLY. ALLOW THE BALLOON TO DEFLATE SLOWLY ON ITS OWN. DO NOT ASPIRATE OR MANUALLY ACCELERATE THE DEFLATION OF THE BALLOON.IF PERMITTED BY HOSPITAL PROTOCOL, THE VALVE ARM MAY BE SEVERED. IF THIS FAILS, CONTACT ADEQUATELY TRAINED PROFESSIONAL FOR ASSISTANCE, AS DIRECTED BY HOSPITAL PROTOCOL. SHOULD BALLOON RUPTURE OCCUR, CARE SHOULD BE TAKEN TO ASSURE THAT ALL BALLOON FRAGMENTS HAVE BEEN REMOVED FROM THE PATIENT. VISUALLY INSPECT THE PRODUCT FOR ANY IMPERFECTIONS OR SURFACE DETERIORATION PRIOR TO USE. RECOMMENDED INFLATION CAPACITIES 5CC BALLOON: USE 10CC STERILE WATER 30CC BALLOON: USE 35CC STERILE WATER DO NOT EXCEED RECOMMENDED CAPACITIES." THE DEVICE WAS NOT RETURNED.

Additional Manufacturer Narrative · 0

THE REPORTED EVENT WAS UNCONFIRMED. THE VISUAL EVALUATION OF THE RETURNED SAMPLE NOTED ONE USED SILICONE CATHETER PRESENT. VISUAL INSPECTION OF THE CATHETER SURFACE NOTED NO OBVIOUS VISIBLE DEFECTS. THE CATHETER BALLOON WAS INFLATED WITH 10ML OF METHYLENE BLUE SOLUTION (3 DROPS 1% AQ METHYLENE BLUE PER 100ML OF DISTILLED WATER). NO LUMEN TO LUMEN LEAKAGE WAS OBSERVED, AND NO LEAKS ALONG THE SHAFT OR AROUND THE CATHETER BALLOON WERE OBSERVED. BALLOON CONCENTRICITY WAS OBSERVED TO BE 60:40. THE CATHETER WAS ALLOWED TO REST FOR 30 MINUTES. NO LEAKS WERE OBSERVED IN THAT TIME PERIOD. THE CATHETER WAS THEN FLUSHED FROM DRAINAGE FUNNEL TO EYES WITH 100ML OF METHYLENE BLUE. NO LEAKS WERE OBSERVED ALONG THE SHAFT. THE CATHETER BALLOON PASSIVELY DEFLATED 10ML OF METHYLENE BLUE WITH NO CUFFING OR RIDGES OBSERVED ON THE BALLOON FOLLOWING DEFLATION. ACTIVE LENGTH OF THE CATHETER BALLOON WAS MEASURED (0.6475) AND FOUND TO BE WITHIN SPECIFICATION (0.5" - 0.8"). THE DEVICE HISTORY RECORD WAS REVIEWED AND FOUND NOTHING THAT COULD HAVE CAUSED OR CONTRIBUTED TO THE REPORTED EVENT. THE INSTRUCTIONS FOR USE STATE THE FOLLOWING: ¿LUBRI-SIL® I.C.®ANTI-MICROBIAL ALL-SILICONE FOLEY CATHETER WITH BARD®HYDROGEL AND BACTI-GUARD®* SILVER ALLOY COATING INFECTION CONTROL ALL-SILICONE FOLEY CATHETER 100% LATEX FREE WARNING: ON CATHETER, DO NOT USE OINTMENTS OR LUBRICANTS HAVING A PETROLATUM BASE. THEY WILL DAMAGE SILICONE AND MAY CAUSE BALLOON TO BURST. WARNING: AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. HANDLE AND DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. CAUTION: FEDERAL (U.S.A.) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. CAUTION: DO NOT ASPIRATE URINE THROUGH DRAINAGE FUNNEL WALL. STORAGE: STORE CATHETERS AT ROOM TEMPERATURE AWAY FROM DIRECT EXPOSURE TO LIGHT, PREFERABLY IN THE ORIGINAL BOX. NOTE: AGGRESSIVE TRACTION PARTICULARLY IN THE PRESENCE OF SUTURING, IS NOT RECOMMENDED FOR 100% SILICONE FOLEY CATHETERS. STERILE UNLESS PACKAGE IS OPENED OR DAMAGED. SINGLE PATIENT USE ONLY. DO NOT REUSE. DO NOT RESTERILIZE. FOR UROLOGICAL USE ONLY. VALVE TYPE: USE LUER SLIP TIP SYRINGE. DO NOT USE NEEDLE. CATHETERS SHOULD BE REPLACED IN ACCORDANCE WITH THE CDC GUIDELINE ¿GUIDELINE FOR PREVENTION OF CATHETER-ASSOCIATED URINARY TRACT INFECTION.¿ AT THE ONSET OR FIRST SIGNS OF A URINARY TRACT INFECTION, CATHETER ENCRUSTATION, OR ANY OTHER CATHETER-RELATED ADVERSE EFFECT, THE CATHETER SHOULD BE REPLACED. TO DEFLATE CATHETER BALLOON: GENTLY INSERT SYRINGE IN THE CATHETER VALVE. NEVER USE MORE FORCE THAN IS REQUIRED TO MAKE THE SYRINGE ¿STICK¿ IN THE VALVE. IF YOU NOTICE SLOW OR NO DEFLATION, RE-SEAT THE SYRINGE GENTLY. ALLOW THE BALLOON TO DEFLATE SLOWLY ON ITS OWN. DO NOT ASPIRATE OR MANUALLY ACCELERATE THE DEFLATION OF THE BALLOON.IF PERMITTED BY HOSPITAL PROTOCOL, THE VALVE ARM MAY BE SEVERED. IF THIS FAILS, CONTACT ADEQUATELY TRAINED PROFESSIONAL FOR ASSISTANCE, AS DIRECTED BY HOSPITAL PROTOCOL. SHOULD BALLOON RUPTURE OCCUR, CARE SHOULD BE TAKEN TO ASSURE THAT ALL BALLOON FRAGMENTS HAVE BEEN REMOVED FROM THE PATIENT. VISUALLY INSPECT THE PRODUCT FOR ANY IMPERFECTIONS OR SURFACE DETERIORATION PRIOR TO USE. RECOMMENDED INFLATION CAPACITIES 5CC BALLOON: USE 10CC STERILE WATER 30CC BALLOON: USE 35CC STERILE WATER DO NOT EXCEED RECOMMENDED CAPACITIES." SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT'S CATHETER ALLEGEDLY DEVELOPED A LEAK AND HAD TO BE CHANGED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT'S CATHETER ALLEGEDLY DEVELOPED A LEAK AND HAD TO BE CHANGED.

Additional Manufacturer Narrative · 1

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. THE INFORMATION PROVIDED BY BARD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BARD. THE DEVICE WAS NOT RETURNED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT'S CATHETER ALLEGEDLY DEVELOPED A LEAK AND HAD TO BE CHANGED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
551538 BARDEX® LUBRI-SIL® I.C. ALL-SILICONE FOLEY CATHETER IC INFECTION COTROL 2-WAY FOLEY CATHETER MJC C.R. BARD, INC. (COVINGTON) -1018233 NGBP4693

Patients

Seq Age Sex Outcome Treatment
1