FDA Adverse Event Malfunction Summary report: N

BD VACUTAINER® PPT¿ PLASMA PREPARATION TUBE K2E 9.0 MG

MDR report key: 7709432 · Received July 22, 2018

Report

Report Number
1917413-2018-03096
Event Type
Malfunction
Date Received
July 22, 2018
Date of Event
July 2, 2018
Report Date
August 28, 2018
Manufacturer
BECTON, DICKINSON & CO.
Product Code
JKA
UDI-DI
50382903627887
PMA / PMN Number
K972075
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

DUE TO AN IT ISSUE BEGINNING ON (B)(6) 2018, PREVIOUSLY FILED EMDRS DID NOT CONTAIN REQUIRED FIELDS. THIS SUPPLEMENTAL EMDR IS FILED TO PROVIDE THE FOLLOWING OMITTED FIELDS: EVENT ATTRIBUTED TO: OTHER; DEVICE SINGLE USE?: NO; DEVICE RETURNED TO MANUFACTURE: NO.

Description of Event or Problem · 0

IT WAS REPORTED THAT BD VACUTAINER PPT PLASMA PREPARATION TUBES K2E 9.0 MG WERE MISSING LABELS. NO REPORT OF INJURY OR MEDICAL INTERVENTION. NO REPORT OF BLOOD EXPOSURE TO MUCOUS MEMBRANE.

Additional Manufacturer Narrative · 1

THERE WERE MULTIPLE LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 7214924, MEDICAL DEVICE EXPIRATION DATE: 08/31/2018, DEVICE MANUFACTURE DATE: 08/02/2017. MEDICAL DEVICE LOT #: 7180795, MEDICAL DEVICE EXPIRATION DATE: 07/31/2018, DEVICE MANUFACTURE DATE: 06/29/2017. INVESTIGATION SUMMARY: BD HAD NOT RECEIVED SAMPLES, BUT PHOTOS WERE PROVIDED BY THE CUSTOMER FACILITY FOR INVESTIGATION. THE PHOTOS WERE EVALUATED AND THE CUSTOMER'S INDICATED FAILURE MODE FOR MISSING LABEL WITH THE INCIDENT LOT WAS OBSERVED. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR THE INCIDENT LOT AND, BASED ON THIS REVIEW, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET; THERE WERE NO RELATED QUALITY NON-CONFORMANCES DURING MANUFACTURING OF THE PRODUCT. INVESTIGATION CONCLUSION: BASED ON EVALUATION OF THE CUSTOMER PHOTOS, THE CUSTOMER¿S INDICATED FAILURE MODE FOR MISSING LABEL WITH THE INCIDENT LOT WAS OBSERVED. ROOT CAUSE DESCRIPTION: BASED ON THE INVESTIGATION, THE MOST LIKELY ROOT CAUSE IS THAT THESE TUBES WERE NOT CULLED FROM THE PRODUCTION LINE BEFORE BEING PLACED IN THE CASE RATIONALE: COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED. THE BD BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS.

Description of Event or Problem · 1

IT WAS REPORTED THAT BD VACUTAINER® PPT¿ PLASMA PREPARATION TUBES K2E 9.0 MG WERE MISSING LABELS. NO REPORT OF INJURY OR MEDICAL INTERVENTION. NO REPORT OF BLOOD EXPOSURE TO MUCOUS MEMBRANE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
551336 BD VACUTAINER® PPT¿ PLASMA PREPARATION TUBE K2E 9.0 MG BLOOD SPECIMEN COLLECTION DEVICE JKA BECTON, DICKINSON & CO. SEE H.10 50382903627887

Patients

Seq Age Sex Outcome Treatment
1 Other