FDA Adverse Event Injury Summary report: N

SILK SUTURE UNKNOWN PRODUCT

MDR report key: 7696069 · Received July 17, 2018

Report

Report Number
2210968-2018-74458
Event Type
Injury
Date Received
July 17, 2018
Report Date
June 26, 2018
Manufacturer
ETHICON INC.
Product Code
GAP
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT THE ETHICON PRODUCT INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POSTOPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THAT ETHICON SUTURE CAUSED/ CONTRIBUTED TO THE NEONATAL DEATH (DUE TO HYPOXIA AND SEPSIS)? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON SUTURE PRODUCTS USED IN THIS PROCEDURE? WOULD THE SURGEON LIKE TO SPEAK WITH ETHICON MEDICAL AND ENGINEERING (TRANSLATION IS AVAILABLE)? CITATION: NEUROL INDIA. 2013; 61: 692-3. DOI: 10.4103/0028-3886.125391. (B)(4).

Description of Event or Problem · 0

TITLE: ANTERIOR CERVICAL MENINGOMYELOCELE IN A NEONATE AUTHORS: G SRIHARI, HOSMANI SHARAN BASAPPA, BADA VIJAY KUMAR, PN HARISH CITATION: NEUROL INDIA. 2013; 61: 692-3. DOI: 10.4103/0028-3886.125391. A (B)(6) GIRL PRESENTED WITH REPEATED RESPIRATORY TRACT INFECTIONS AT ANOTHER FACILITY. CHEST X-RAY REVEALED RIGHT LUNG HAZINESS. SUSPECTING RIGHT PLEURAL EFFUSION, INADVERTENTLY RIGHT INTERCOSTAL DRAIN (ICD) WAS PLACED AND CLEAR CEREBROSPINAL FLUID (CSF) WAS DRAINED. SUBSEQUENTLY, THE CHILD WAS REFERRED TO THE CENTER. MAGNETIC RESONANCE IMAGING OF THE ENTIRE SPINE SHOWED LARGE ANTERIOR CERVICAL MENINGOMYELOCELE (ACM) AT C6 LEVEL EXTENDING INFERIORLY INTO THE POSTERIOR MEDIASTINUM AND CAUSING RIGHT LUNG COLLAPSE AND HYDROTHORAX. CONSIDERING THE AGE AND POOR GENERAL CONDITION, SHE WAS PLANNED FOR A SIMPLE LIGATION OF THE SAC AND DISCONNECTION OF THE DISTAL SAC. DURING THE SURGICAL PROCEDURE, THE NECK OF THE SAC WAS LIGATED IN FLUSH WITH VERTEBRAL BODY DEFECT WITH MERSILK SUTURE AND DISCONNECTED FROM THE REST OF THE SAC. IMMEDIATE POST-OPERATIVELY, THE PATIENT HAD ICD SITE INFECTION AS CULTURE SHOWED KLEBSIELLA PNEUMONIAE SENSITIVE TO THE DRUG WHICH WAS TREATED WITH CEFOPERAZONE. BLOOD CULTURE GREW CANDIDIASIS WHICH WAS TREATED WITH FLUCONAZOLE. AFTER EXTENDED STAY IN THE INTENSIVE CARE UNIT FOR 4 WEEKS, THE PATIENT¿S ESOPHAGEAL FISTULA AND ICD SITE FISTULA CLOSED SPONTANEOUSLY. HOWEVER, SHE HAD REPEATED EPISODES OF BREATHLESSNESS AND FALL IN SATURATION, WHICH WERE DUE TO ASPIRATION/INFECTIONS AND WERE MANAGED WITH BRONCHODILATORS, ANTIBIOTICS, AND CHEST PHYSIOTHERAPY. TWO MONTHS AFTER DISCHARGE, THE PATIENT EXPIRED PRESUMABLY DUE TO HYPOXIA/ASPIRATION/SEPSIS. IT WAS CONCLUDED THAT THE ANTERIOR CERVICAL APPROACH SEEMS TO BE THE MOST DIRECT APPROACH FOR ADDRESSING THE ANTERIOR CERVICAL MENINGOCELES. THE PRESENT CASE DEMONSTRATES THE CHALLENGES IN THE MANAGEMENT OF THIS RARE CLINICAL ENTITY WHEN ENCOUNTERED IN AN INFANT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
535084 SILK SUTURE UNKNOWN PRODUCT SUTURE, NONABSORBABLE, SILK GAP ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
0 Required Intervention