FDA Adverse Event Injury Summary report: N

VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT

MDR report key: 7682661 · Received July 12, 2018

Report

Report Number
2210968-2018-74301
Event Type
Injury
Date Received
July 12, 2018
Report Date
June 28, 2018
Manufacturer
ETHICON INC.
Product Code
GAM
PMA / PMN Number
K022269
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). CITATION: INT J COLORECTAL DIS. 2010; 25: 381¿387. DOI: 10.1007/S00384-009-0840-X. [(B)(4)].

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: LAPAROSCOPIC CORRECTION OF ENTEROCELE ASSOCIATED TO STAPLED TRANSANAL RECTAL RESECTION FOR OBSTRUCTED DEFECATION SYNDROME" AUTHORS: ALFONSO CARRIERO, MARCELLO PICCHIO, JACOPO MARTELLUCCI, PASQUALE TALENTO, DOMENICO PALIMENTO, ERASMO SPAZIANI. CITATION: INT J COLORECTAL DIS. 2010; 25: 381¿387. DOI: 10.1007/S00384-009-0840-X. THE AUTHORS REPORTED THEIR EXPERIENCE OF CONCOMITANT LAPAROSCOPIC TREATMENT FOR ENTEROCELE AND STAPLED TRANSANAL RECTAL RESECTION (STARR) FOR RECTOCELE AND/OR RECTAL PROLAPSE IN PATIENTS WITH COMPLEX OBSTRUCTED DEFECATION SYNDROME (ODS). FROM JUNE 2005 TO JUNE 2007, THE AUTHORS SUBMITTED 20 PATIENTS (19 FEMALES AND 1 MALE PATIENT; AGE RANGE: 36 TO 75 YEARS OLD) WITH ODS DUE TO RECTAL PROLAPSE AND/OR RECTOCELE, COMBINED WITH STABLE ENTEROCELE, TO STARR AND LAPAROSCOPIC CORRECTION OF THE ENTEROCELE. AFTER EXPOSURE OF THE PELVIS HOLDING BACK THE SMALL BOWEL, STARR PROCEDURE WAS PERFORMED. A TOTAL OF 16 PROCEDURES WERE PERFORMED WITH THE PPH-01 STAPLED ANOPLASTY KIT (ETHICON) AND 3 PROCEDURES WITH CONTOUR TRANSTAR (ETHICON). THE LAPAROSCOPIC PROCEDURE AIMED TO EXCISE THE ENTEROCELE SAC AND OBLITERATE DOUGLAS¿ CUL-DE-SAC. AFTER PROPER DISSECTION OF THE ENTIRE SAC WITH MONOPOLAR DIATHERMY, A RUNNING SUTURE OF THE PERITONEAL MARGINS WITH VICRYL 2-0 SUTURE WAS PERFORMED. REPORTED COMPLICATIONS INCLUDED RECTAL BLEEDING (N-1) WHICH WAS TREATED CONSERVATIVELY, RETROPNEUMOPERITONEUM (N-1) WHICH REQUIRED ANTIBIOTIC THERAPY FOR 7 DAYS AND THE EVENT RESOLVED AFTER, AND POST-OPERATIVE URGENCY NOT ASSOCIATED WITH PRE-OPERATIVE URGENCY (N-3). IT WAS CONCLUDED THAT THE COMBINATION OF STARR AND LAPAROSCOPY PROVIDES A SAFE AND EFFECTIVE METHOD TO TREAT ODS CAUSED BY RECTAL INTERNAL PROLAPSE AND/OR RECTOCELE AND COMBINED WITH ENTEROCELE AND OTHER PELVIC FLOOR ABNORMALITIES. LARGER STUDIES WITH LONG-TERM FOLLOW-UP ARE NECESSARY TO ASSESS THE RESULTS OF THIS NEW COMBINED SURGICAL PROCEDURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
526094 VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT SUTURE, ABSORBABLE, SYNTHETIC GAM ETHICON INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention