FDA Adverse Event Injury Summary report: N

SURGICEL ABSORBABLE HEMOSTAT

MDR report key: 7672589 · Received July 9, 2018

Report

Report Number
2210968-2018-74200
Event Type
Injury
Date Received
July 9, 2018
Report Date
June 28, 2018
Manufacturer
ETHICON INC.
Product Code
LMF
PMA / PMN Number
N12159
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS THROUGH A JOURNAL ARTICLE. NO SPECIFIC PATIENT INFORMATION REGARDING EVENTS HAS BEEN PROVIDED AND IT IS UNKNOWN IF THE EVENTS HAVE BEEN PREVIOUSLY REPORTED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. IF FURTHER DETAILS ARE RECEIVED AT THE LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT THE ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POSTOPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON SUTURE PRODUCTS USED IN THIS PROCEDURE?

Description of Event or Problem · 1

IT WAS REPORTED IN A JOURNAL ARTICLE ENTITLED: STAPLED ANOPEXY AND STARR IN SURGICAL TREATMENT OF HAEMORRHOIDAL DISEASE AUTHORS: ITALO CORSALE, MARCO RIGUTINI, NICCOLO FRANCIOLI, SONIA PANICUCCI, PIETRO ADRIANO MORI, FRANCESCO ALOISE CITATION: UPDATES SURG. 2014; 66: 217¿222. DOI: 10.1007/S13304-014-0254-3. THE AUTHORS CARRIED OUT A RETROSPECTIVE INQUIRY OF THEIR EXPERIENCE IN THE SURGICAL TREATMENT OF THE HEMORRHOIDAL DISEASE, ANALYZING THE RESULTS OF THE 2 SURGICAL METHODS AND UNDERLINING THE FACTORS THAT ARE IN THEIR OPINION ESSENTIAL FOR A CORRECT THERAPEUTIC PLANNING. IN ORDER TO LIMIT THE INCIDENCE OF FAILURES, THE AUTHORS PROVIDED A REMOVAL TECHNIQUE OF GREATER AMOUNT OF PROLAPSED TISSUE THAT WAS CONSIDERED AN OPPORTUNITY TO USE THE STARR TECHNIQUE EVEN IN THE PRESENCE OF HEMORRHOIDAL DISEASE NOT BURDENED BY SYMPTOMS OF OBSTRUCTED DEFECATION. THE AUTHORS EVALUATED THE EARLY AND AT A DISTANCE RESULTS OF 285 PATIENTS WHO UNDERWENT SURGICAL RESECTION WITH TRANS-ANAL CIRCULAR STAPLER FOR SYMPTOMATIC III-IV DEGREE HEMORRHOIDS WITHOUT OBSTRUCTED DEFECATION DISORDERS. OF WHICH, 237 PATIENTS (94 MALE AND 143 FEMALE PATIENTS; AGE RANGE: 29 TO 71 YEARS OLD) WERE SUBJECTED TO STAPLED ANOPEXY PROCEDURE (SA), WHILE THE REMAINING 48 PATIENTS (27 MALE AND 21 FEMALE PATIENTS; AGE RANGE: 33 TO 71 YEARS OLD) UNDERWENT THE STAPLED TRANSANAL RECTAL RESECTION (STARR) PROCEDURE. IN THE SA GROUP, AN SA PROCEDURE WAS PERFORMED, 4 CM OVER THE LINEA DENTATA, A SUTURE SHAPED AS A TOBACCO BAG AND RESECTING THE PROLAPSE USING PPH-03 CIRCULAR STAPLER (ETHICON). IN THE STARR PROCEDURE, AS THE PROLAPSE OCCUPIED THE CIRCULAR ANAL DIVARICATOR (CAD) OVER THE HALF OF THE DEVICE, THE AUTHORS SUGGESTED TO CARRY OUT A STARR PROCEDURE PERFORMING TWO PARACHUTE SUTURES, ONE ON THE FRONT RECTAL WALL AND THE OTHER ONE ON THE REAR WALL, WITH 3 TRACTION STITCHES AND RESECTING THEM SEPARATELY BY MEANS OF 2 PPH-01 CIRCULAR STAPLERS (ETHICON) IN 13 CASES, OR 1 PPH-03 CIRCULAR STAPLER ON THE FRONT AND 1 PPH-01 CIRCULAR STAPLER ON THE REAR PART FOR 35 PATIENTS. IN BOTH GROUPS, HEMOSTASIS AT THE END OF OPERATION WAS GUARANTEED BY TRANSUTURAL STITCHES AND TRANS-ANAL TABOTAMP HEMOSTATIC PAD (ETHICON). IN THE SA GROUP, REPORTED COMPLICATIONS INCLUDED PERSISTENT RECTUM BLEEDING (N-7) WHICH REQUIRED RE-ADMISSION AND CONSERVATIVE THERAPY, RECTUM HEMATOMA (N-1), STENOSIS (N-6) WHICH WERE TREATED WITH CONSERVATIVE THERAPY, DEFECATION URGENCY (N-7), SYMPTOMATIC RECURRENCE (N-9), AND ASYMPTOMATIC RESIDUAL DISEASE (N-40). IN THE STARR GROUP, REPORTED COMPLICATIONS INCLUDED PERSISTENT RECTUM BLEEDING (N-2) WHICH REQUIRED HEMOSTASIS IN THE OPERATING ROOM (N-1) AND RE ADMISSION AND CONSERVATIVE THERAPY (N-1), HEMATOMA OF THE POSTERIOR RECTUM (N-1) WHICH WAS INITIALLY TREATED CONSERVATIVELY AND LATER BY TRANS-ANAL SURGERY DUE TO PERSISTENT SENSATION OF OBSTACLE TO DEFECATION, STENOSIS (N-1) WHICH WAS FIRST TREATED WITH DILATATION WITH HEGAR PROBE AND THEN SURGICALLY THROUGH TRANSANAL SCAR EXCISION, CHRONIC ANAL PAIN (N-1) WHICH REQUIRED ADMINISTRATION OF ANALGESIC DRUGS, DEFECATION URGENCY (N-2) WHICH REQUIRED PELVIC BIOFEEDBACK (N-1), SYMPTOMATIC RECURRENCE (N-2), AND ASYMPTOMATIC RESIDUAL DISEASE (N-4). IT WAS REPORTED THAT THE SA TECHNIQUE OFFERS THE ADVANTAGE OF LESS POST-OPERATIVE PAIN, A QUICKER RECOVERY OF THE WORKING ACTIVITY, AND ALSO REPORTS A NON-RELEVANT OCCURRENCE OF POST-OPERATIVE BLEEDING AS COMPARED TO THE TRADITIONAL HEMORRHOIDECTOMY. IN THE CASE OF VOLUMINOUS PROLAPSES THAT APPEAR WITH THE HEMORRHOIDAL DISEASE ONLY, THE STARR PROCEDURE IS A SAFE TECHNIQUE AND CAN OPTIMIZE THE LONG LASTING EFFECTIVENESS OF THE TRANS-ANAL RESECTION SURGERY LIMITING THE INCIDENCE OF SYMPTOMATIC RELAPSE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
514268 SURGICEL ABSORBABLE HEMOSTAT HEMOSTATIC AGENT, ABSORBABLE LMF ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention