FDA Adverse Event Injury Summary report: N

GDC 18-STANDARD SYNERG DETECTION CIRCUIT

MDR report key: 766767 · Received September 28, 2006

Report

Report Number
6000078-2006-00501
Event Type
Injury
Date Received
September 28, 2006
Report Date
August 21, 2006
Manufacturer
NEUROVASCULAR, A DIVISION OF BOSTON SCIENTIFIC CORP
Product Code
HCG
PMA / PMN Number
K991134
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
UK
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE DEVICE IN QUESTION WILL NOT BE RETURNED TO BOSTON SCIENTIFIC AS IT WAS IMPLANTED INTO THE PT. THEREFORE, BOSTON SCIENTIFIC CANNOT CONCLUSIVELY DETERMINE THE CAUSE OF THE USER'S EXPERIENCE. IF FURTHER SIGNIFICANT INFO IS FOUND, A SUPPLEMENTAL REPORT WILL FOLLOW. ADD'L K001083.

Description of Event or Problem · 1

THE PHYSICIAN REPORTED, THE PT SUFFERED A STROKE FOLLOWING THE TREATMENT OF AN ANEURYSM. IMAGING REVEALED A POSSIBLE INFLAMMATORY REACTION SURROUNDING THE TREATED ANEURYSM. THE PHYSICIAN REPORTED HE WILL PROVIDE BOSTON SCIENTIFIC A FULL WRITTEN REPORT AND IMAGES FOR INVESTIGATION WHICH WILL INCLUDE THE PT'S CONDITION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 GDC 18-STANDARD SYNERG DETECTION CIRCUIT DETACHABLE COIL HCG NEUROVASCULAR, A DIVISION OF BOSTON SCIENTIFIC CORP 350103-4 UNK

Patients

Seq Age Sex Outcome Treatment
1 48 YR Required Intervention MATRIX2 STANDARD 360 SR 10MM X 30CM.| MATRIX 2 STANDARD 360 SR 9MM X 30CM.| MATRIX2 FIRM 360 20MM X 30CM.| GDC-18 2D 18MM X 30CM.| GDC-18 360 22MM X 40CM.| MATRIX2 STANDARD 360 SR 7MM X 20CM.| GDC-18 2D 14MM X 30CM.| MATRIX2 SOFT 360 SR 8MM X 30CM.| GDC-18 STANDARD 9MM X 30CM.| MATRIX2 STANDARD 360 SR 7MM X 20CM.| MATRIX 2 ULTRASOFT 360 SR 5MM X 15CM.| GDC-10 STANDARD 8MM X 30CM.| MATRIX2 STANDARD 360 SR 8MM X 30CM.| GDC-18 360 18MM X 40CM.| GDC-18 2D 20MM X 30CM.| GDC-18 360 18MM X 40CM.| MATRIX SOFT 360 SR 4MM X 8CM.| MATRIX 2 ULTRASOFT 360 SR 4MM X 8CM.| MATRIX2 SOFT 360 SR 8MM X 30CM. MA| GDC-18 2D 12MM X 30CM.| MATRIX 2 SOFT 360 SR 7MM X 20CM.| GDC-18 360 20MM X 33CM.| GDC-18 360 22MM X 40CM.| MATRIX FIRM 360 24MMX 40CM.| MATRIX2 STANDARD 360 SR 8MM X 20CM.| MATRIX2 STANDARD 360 SR 7MM X 20CM.| MATRIX2 STANDARD 360 SR 8MM X 30CM.| GDC-18 2D 18MM X 30CM.| GDC-18 360 12MM X 30CM.| GDC-18 360 20MM X 33CM.| MATRIX2 STANDARD 360 SR 12MM X 30CM.| MATRIX2 FIRM 360 18MM X 30CM.| MATRIX2 SOFT 360 SR 8MM X 20CM.| MATRIX2 SOFT 360 SR 7MM X 20CM.| GDC-18 STANDARD 9MM X 30CM.| GDC-18 STANDARD 10MM X 30CM.